68 research outputs found

    Cancelable ECG Biometrics using Compressive Sensing-Generalized Likelihood Ratio Test

    Get PDF
    Electrocardiogram (ECG) has been investigated as promising biometrics, but it cannot be canceled and re-used once compromised just like other biometrics. We propose methods to overcome the issue of irrevocability in ECG biometrics without compromising performance. Our proposed cancelable user authentication uses a generalized likelihood ratio test (GLRT) based on a composite hypothesis testing in compressive sensing (CS) domain We also propose a permutation-based revocation method for CS-based cancelable biometrics so that it becomes resilient to record multiplicity attack. In addition, to compensate for inevitable performance degradation due to cancelable schemes, we also propose two performance improvement methods without undermining cancelable schemes: a self-guided ECG filtering and a T-wave shift model in our CS-GLRT. Finally, our proposed methods were evaluated for various cancelable biometrics criteria with the public ECG-ID data (89 subjects). Our cancelable ECG biometric methods yielded up to 93.0% detection probability at 2.0% false alarm ratio (PD*) and 3.8% equal error rate (EER), which are comparable to or even better than non-cancelable baseline with 93.2% PD* and 4.8% EER for challenging single pulse ECG authentication, respectively. Our proposed methods met all cancelable biometrics criteria theoretically or empirically. Our cancelable secure user template with our novel revocation process is practically non-invertible and robust to record multiplicity attack

    Sparsity-Aware Low-Power ADC Architecture with Advanced Reconstruction Algorithms

    Get PDF
    Compressive sensing (CS) technique enables a universal sub-Nyquist sampling of sparse and compressible signals, while still guaranteeing the reliable signal recovery. Its potential lies in the reduced analog-to-digital conversion rate in sampling broadband and/or multi-channel sparse signals, where conventional Nyquist-rate sampling are either technology impossible or extremely hardware costly. Nevertheless, there are many challenges in the CS hardware design. In coherent sampling, state-of-the-art mixed-signal CS front-ends, such as random demodulator and modulated wideband converter, suffer from high power and nonlinear hardware. In signal recovery, state-of-the-art CS reconstruction methods have tractable computational complexity and probabilistically guaranteed performance. However, they are still high cost (basis pursuit) or noise sensitive (matching pursuit). In this dissertation, we propose an asynchronous compressive sensing (ACS) front-end and advanced signal reconstruction algorithms to address these challenges. The ACS front-end consists of a continuous-time ternary encoding (CT-TE) scheme which converts signal amplitude variations into high-rate ternary timing signal, and a digital random sampler (DRS) which captures the ternary timing signal at sub-Nyquist rate. The CT-TE employs asynchronous sampling mechanism for pulsed-like input and has signal-dependent conversion rate. The DRS has low power, ease of massive integration, and excellent linearity in comparison to state-of-the-art mixed-signal CS front-ends. We propose two reconstruction algorithms. One is group-based total variation, which exploits piecewise-constant characteristics and achieves better mean squared error and faster convergence rate than the conventional TV scheme with moderate noise. The second algorithm is split-projection least squares (SPLS), which relies on a series of low-complexity and independent l2-norm problems with the prior on ternary-valued signal. The SPLS scheme has good noise robustness, low-cost signal reconstruction and facilitates a parallel hardware for real-time signal recovery. In application study, we propose multi-channel filter banks ACS front-end for the interference-robust radar. The proposed receiver performs reliable target detection with nearly 8-fold data compression than Nyquist-rate sampling in the presence of -50dBm wireless interference. We also propose an asynchronous compressed beamformer (ACB) for low-power portable diagnostic ultrasound. The proposed ACB achieves 9-fold data volume compression and only 4.4% contrast-to-noise ratio loss on the imaging results when compared with the Nyquist-rate ADCs

    Finite Rate of Innovation Based Modeling and Compression of ECG Signals

    Get PDF
    Mobile health is gaining increasing importance for society and the quest for new power efficient devices sampling biosignals is becoming critical. We discuss a new scheme called Variable PulseWidth Finite Rate of Innovation (VPW-FRI) to model and compress ECG signals. This technique generalizes classical FRI estimation to enable the use of a sum of asymmetric Cauchy-based pulses for modeling electrocardiogram (ECG) signals. We experimentally show that VPW-FRI indeed models ECG signals with increased accuracy compared to current standards. In addition, we study the compression efficiency of the method: compared with various widely used compression schemes, we showcase improvements in terms of compression efficiency as well as sampling rate

    Rakeness in the design of Analog-to-Information Conversion of Sparse and Localized Signals

    Full text link
    Design of Random Modulation Pre-Integration systems based on the restricted-isometry property may be suboptimal when the energy of the signals to be acquired is not evenly distributed, i.e. when they are both sparse and localized. To counter this, we introduce an additional design criterion, that we call rakeness, accounting for the amount of energy that the measurements capture from the signal to be acquired. Hence, for localized signals a proper system tuning increases the rakeness as well as the average SNR of the samples used in its reconstruction. Yet, maximizing average SNR may go against the need of capturing all the components that are potentially non-zero in a sparse signal, i.e., against the restricted isometry requirement ensuring reconstructability. What we propose is to administer the trade-off between rakeness and restricted isometry in a statistical way by laying down an optimization problem. The solution of such an optimization problem is the statistic of the process generating the random waveforms onto which the signal is projected to obtain the measurements. The formal definition of such a problems is given as well as its solution for signals that are either localized in frequency or in more generic domain. Sample applications, to ECG signals and small images of printed letters and numbers, show that rakeness-based design leads to non-negligible improvements in both cases

    Asynchronous Signal Processing for Compressive Data Transmission

    Get PDF
    In this thesis we propose a power-efficient procedure useful in the acquisition of biological data in digital form without using high frequency samplers. The data is compressed so that transmission is limited to parts of the signal that are significant. Our procedure uses an asynchronous sigma delta modulator (ASDM) together with a time-to-digital converter (TDC) to obtain binary data that is transmitted via orthogonal frequency division multiplexing (OFDM). The asynchronous sigma delta modulator is a nonlinear feedback system that allows the representation of bounded signals by zero-crossing times of a binary signal. Using duty-cycle modulation, the ASDM is shown to be equivalent to an optimal level-crossing sampler. The zero-crossing times are measured with a time-to-digital converter that applies pulse-shrinking delay lines and requires no high-frequency clock. Reconstruction of the original signal is possible from the zero-crossing times of the ASDM output binary signal. ASDM time-domain compression is compared with discrete wavelet transform based data compression. For wireless data transmission, the orthogonal frequency division multiplexing (OFDM) reduces the bit error-rate in multipath fading channels. The performance of the proposed algorithm is illustrated using an electrocardiogram signal, which fits the bursty characteristic appropriate for our procedure

    ON SOME COMMON COMPRESSIVE SENSING RECOVERY ALGORITHMS AND APPLICATIONS

    Get PDF
    Compressive Sensing, as an emerging technique in signal processing is reviewed in this paper together with its’ common applications. As an alternative to the traditional signal sampling, Compressive Sensing allows a new acquisition strategy with significantly reduced number of samples needed for accurate signal reconstruction. The basic ideas and motivation behind this approach are provided in the theoretical part of the paper. The commonly used algorithms for missing data reconstruction are presented. The Compressive Sensing applications have gained significant attention leading to an intensive growth of signal processing possibilities. Hence, some of the existing practical applications assuming different types of signals in real-world scenarios are described and analyzed as well

    Robust Algorithms for Unattended Monitoring of Cardiovascular Health

    Get PDF
    Cardiovascular disease is the leading cause of death in the United States. Tracking daily changes in one’s cardiovascular health can be critical in diagnosing and managing cardiovascular disease, such as heart failure and hypertension. A toilet seat is the ideal device for monitoring parameters relating to a subject’s cardiac health in his or her home, because it is used consistently and requires no change in daily habit. The present work demonstrates the ability to accurately capture clinically relevant ECG metrics, pulse transit time based blood pressures, and other parameters across subjects and physiological states using a toilet seat-based cardiovascular monitoring system, enabled through advanced signal processing algorithms and techniques. The algorithms described herein have been designed for use with noisy physiologic signals measured at non-standard locations. A key component of these algorithms is the classification of signal quality, which allows automatic rejection of noisy segments before feature delineation and interval extractions. The present delineation algorithms have been designed to work on poor quality signals while maintaining the highest possible temporal resolution. When validated on standard databases, the custom QRS delineation algorithm has best-in-class sensitivity and precision, while the photoplethysmogram delineation algorithm has best-in-class temporal resolution. Human subject testing on normative and heart failure subjects is used to evaluate the efficacy of the proposed monitoring system and algorithms. Results show that the accuracy of the measured heart rate and blood pressure are well within the limits of AAMI standards. For the first time, a single device is capable of monitoring long-term trends in these parameters while facilitating daily measurements that are taken at rest, prior to the consumption of food and stimulants, and at consistent times each day. This system has the potential to revolutionize in-home cardiovascular monitoring

    Intelligent Biosignal Processing in Wearable and Implantable Sensors

    Get PDF
    This reprint provides a collection of papers illustrating the state-of-the-art of smart processing of data coming from wearable, implantable or portable sensors. Each paper presents the design, databases used, methodological background, obtained results, and their interpretation for biomedical applications. Revealing examples are brain–machine interfaces for medical rehabilitation, the evaluation of sympathetic nerve activity, a novel automated diagnostic tool based on ECG data to diagnose COVID-19, machine learning-based hypertension risk assessment by means of photoplethysmography and electrocardiography signals, Parkinsonian gait assessment using machine learning tools, thorough analysis of compressive sensing of ECG signals, development of a nanotechnology application for decoding vagus-nerve activity, detection of liver dysfunction using a wearable electronic nose system, prosthetic hand control using surface electromyography, epileptic seizure detection using a CNN, and premature ventricular contraction detection using deep metric learning. Thus, this reprint presents significant clinical applications as well as valuable new research issues, providing current illustrations of this new field of research by addressing the promises, challenges, and hurdles associated with the synergy of biosignal processing and AI through 16 different pertinent studies. Covering a wide range of research and application areas, this book is an excellent resource for researchers, physicians, academics, and PhD or master students working on (bio)signal and image processing, AI, biomaterials, biomechanics, and biotechnology with applications in medicine
    corecore