13,999 research outputs found

    Design and implementation of a multi-modal biometric system for company access control

    Get PDF
    This paper is about the design, implementation, and deployment of a multi-modal biometric system to grant access to a company structure and to internal zones in the company itself. Face and iris have been chosen as biometric traits. Face is feasible for non-intrusive checking with a minimum cooperation from the subject, while iris supports very accurate recognition procedure at a higher grade of invasivity. The recognition of the face trait is based on the Local Binary Patterns histograms, and the Daughman\u2019s method is implemented for the analysis of the iris data. The recognition process may require either the acquisition of the user\u2019s face only or the serial acquisition of both the user\u2019s face and iris, depending on the confidence level of the decision with respect to the set of security levels and requirements, stated in a formal way in the Service Level Agreement at a negotiation phase. The quality of the decision depends on the setting of proper different thresholds in the decision modules for the two biometric traits. Any time the quality of the decision is not good enough, the system activates proper rules, which ask for new acquisitions (and decisions), possibly with different threshold values, resulting in a system not with a fixed and predefined behaviour, but one which complies with the actual acquisition context. Rules are formalized as deduction rules and grouped together to represent \u201cresponse behaviors\u201d according to the previous analysis. Therefore, there are different possible working flows, since the actual response of the recognition process depends on the output of the decision making modules that compose the system. Finally, the deployment phase is described, together with the results from the testing, based on the AT&T Face Database and the UBIRIS database

    Postmortem iris recognition and its application in human identification

    Full text link
    Iris recognition is a validated and non-invasive human identification technology currently implemented for the purposes of surveillance and security (i.e. border control, schools, military). Similar to deoxyribonucleic acid (DNA), irises are a highly individualizing component of the human body. Based on a lack of genetic penetrance, irises are unique between an individual’s left and right iris and between identical twins, proving to be more individualizing than DNA. At this time, little to no research has been conducted on the use of postmortem iris scanning as a biometric measurement of identification. The purpose of this pilot study is to explore the use of iris recognition as a tool for postmortem identification. Objectives of the study include determining whether current iris recognition technology can locate and detect iris codes in postmortem globes, and if iris scans collected at different postmortem time intervals can be identified as the same iris initially enrolled. Data from 43 decedents involving 148 subsequent iris scans demonstrated a subsequent match rate of approximately 80%, supporting the theory that iris recognition technology is capable of detecting and identifying an individual’s iris code in a postmortem setting. A chi-square test of independence showed no significant difference between match outcomes and the globe scanned (left vs. right), and gender had no bearing on the match outcome. There was a significant relationship between iris color and match outcome, with blue/gray eyes yielding a lower match rate (59%) compared to brown (82%) or green/hazel eyes (88%), however, the sample size of blue/gray eyes in this study was not large enough to draw a meaningful conclusion. An isolated case involving an antemortem initial scan collected from an individual on life support yielded an accurate identification (match) with a subsequent scan captured at approximately 10 hours postmortem. Falsely rejected subsequent iris scans or "no match" results occurred in about 20% of scans; they were observed at each PMI range and varied from 19-30%. The false reject rate is too high to reliably establish non-identity when used alone and ideally would be significantly lower prior to implementation in a forensic setting; however, a "no match" could be confirmed using another method. Importantly, the data showed a false match rate or false accept rate (FAR) of zero, a result consistent with previous iris recognition studies in living individuals. The preliminary results of this pilot study demonstrate a plausible role for iris recognition in postmortem human identification. Implementation of a universal iris recognition database would benefit the medicolegal death investigation and forensic pathology communities, and has potential applications to other situations such as missing persons and human trafficking cases

    Pigment Melanin: Pattern for Iris Recognition

    Full text link
    Recognition of iris based on Visible Light (VL) imaging is a difficult problem because of the light reflection from the cornea. Nonetheless, pigment melanin provides a rich feature source in VL, unavailable in Near-Infrared (NIR) imaging. This is due to biological spectroscopy of eumelanin, a chemical not stimulated in NIR. In this case, a plausible solution to observe such patterns may be provided by an adaptive procedure using a variational technique on the image histogram. To describe the patterns, a shape analysis method is used to derive feature-code for each subject. An important question is how much the melanin patterns, extracted from VL, are independent of iris texture in NIR. With this question in mind, the present investigation proposes fusion of features extracted from NIR and VL to boost the recognition performance. We have collected our own database (UTIRIS) consisting of both NIR and VL images of 158 eyes of 79 individuals. This investigation demonstrates that the proposed algorithm is highly sensitive to the patterns of cromophores and improves the iris recognition rate.Comment: To be Published on Special Issue on Biometrics, IEEE Transaction on Instruments and Measurements, Volume 59, Issue number 4, April 201
    • …
    corecore