35,414 research outputs found

    On angled bounce-off impact of a drop impinging on a flowing soap film

    Get PDF
    Small drops impinging angularly on thin flowing soap films frequently demonstrate the rare emergence of bulk elastic effects working in-tandem with the more common-place hydrodynamic interactions. Three collision regimes are observable: (a) drop piercing through the film, (b) it coalescing with the flow, and (c) it bouncing off the film surface. During impact, the drop deforms along with a bulk elastic deformation of the film. For impacts that are close-to-tangential, the bounce-off regime predominates. We outline a reduced order analytical framework assuming a deformable drop and a deformable three-dimensional film, and the idealization invokes a phase-based parametric study. Angular inclination of the film and the ratio of post and pre impact drop sizes entail the phase parameters. We also perform experiments with vertically descending droplets impacting against an inclined soap film, flowing under constant pressure head. Model predicted phase domain for bounce-off compares well to our experimental findings. Additionally, the experiments exhibit momentum transfer to the film in the form of shed vortex dipole, along with propagation of free surface waves. On consulting prior published work, we note that for locomotion of water-walking insects using an impulsive action, the momentum distribution to the shed vortices and waves are both significant, taking up respectively 2/3-rd and 1/3-rd of the imparted streamwise momentum. In view of the potentially similar impulse actions, this theory is applied to the bounce-off examples in our experiments, and the resultant shed vortex dipole momenta are compared to the momenta computed from particle imaging velocimetry data. The magnitudes reveal identical order (10−710^{-7} N⋅\cdots), suggesting that the bounce-off regime can be tapped as a simple analogue for interfacial bio-locomotion relying on impulse reactions

    Touchalytics: On the Applicability of Touchscreen Input as a Behavioral Biometric for Continuous Authentication

    Full text link
    We investigate whether a classifier can continuously authenticate users based on the way they interact with the touchscreen of a smart phone. We propose a set of 30 behavioral touch features that can be extracted from raw touchscreen logs and demonstrate that different users populate distinct subspaces of this feature space. In a systematic experiment designed to test how this behavioral pattern exhibits consistency over time, we collected touch data from users interacting with a smart phone using basic navigation maneuvers, i.e., up-down and left-right scrolling. We propose a classification framework that learns the touch behavior of a user during an enrollment phase and is able to accept or reject the current user by monitoring interaction with the touch screen. The classifier achieves a median equal error rate of 0% for intra-session authentication, 2%-3% for inter-session authentication and below 4% when the authentication test was carried out one week after the enrollment phase. While our experimental findings disqualify this method as a standalone authentication mechanism for long-term authentication, it could be implemented as a means to extend screen-lock time or as a part of a multi-modal biometric authentication system.Comment: to appear at IEEE Transactions on Information Forensics & Security; Download data from http://www.mariofrank.net/touchalytics

    Escape Time Characterization of Pendular Fabry-Perot

    Full text link
    We show that an escape from the potential minimum of Fabry-Perot interferometers can be detected measuring the associated sudden change of reflectivity. We demonstrate that the loss of information that occurs retaining only the sequence of escapes, rather than the full trajectory, can be very mild and can lead to an effective method to reveal the noise intensity or the presence of a coherent signal

    Computational modelling of emboli travel trajectories in cerebral arteries: Influence of microembolic particle size and density

    Get PDF
    This article has been made available through the Brunel Open Access Publishing Fund.Ischaemic stroke is responsible for up to 80 % of stroke cases. Prevention of the reoccurrence of ischaemic attack or stroke for patients who survived the first symptoms is the major treatment target. Accurate diagnosis of the emboli source for a specific infarction lesion is very important for a better treatment for the patient. However, due to the complex blood flow patterns in the cerebral arterial network, little is known so far of the embolic particle flow trajectory and its behaviour in such a complex flow field. The present study aims to study the trajectories of embolic particles released from carotid arteries and basilar artery in a cerebral arterial network and the influence of particle size, mass and release location to the particle distributions, by computational modelling. The cerebral arterial network model, which includes major arteries in the circle of Willis and several generations of branches from them, was generated from MRI images. Particles with diameters of 200, 500 and 800 μ m and densities of 800, 1,030 and 1,300 kg/m 3 were released in the vessel's central and near-wall regions. A fully coupled scheme of particle and blood flow in a computational fluid dynamics software ANASYS CFX 13 was used in the simulations. The results show that heavy particles (density large than blood or a diameter larger than 500 μ m) normally have small travel speeds in arteries; larger or lighter embolic particles are more likely to travel to large branches in cerebral arteries. In certain cases, all large particles go to the middle cerebral arteries; large particles with higher travel speeds in large arteries are likely to travel at more complex and tortuous trajectories; emboli raised from the basilar artery will only exit the model from branches of basilar artery and posterior cerebral arteries. A modified Circle of Willis configuration can have significant influence on particle distributions. The local branch patterns of internal carotid artery to middle cerebral artery and anterior communicating artery can have large impact on such distributions. © 2014 The Author(s)

    Computer graphics application in the engineering design integration system

    Get PDF
    The computer graphics aspect of the Engineering Design Integration (EDIN) system and its application to design problems were discussed. Three basic types of computer graphics may be used with the EDIN system for the evaluation of aerospace vehicles preliminary designs: offline graphics systems using vellum-inking or photographic processes, online graphics systems characterized by direct coupled low cost storage tube terminals with limited interactive capabilities, and a minicomputer based refresh terminal offering highly interactive capabilities. The offline line systems are characterized by high quality (resolution better than 0.254 mm) and slow turnaround (one to four days). The online systems are characterized by low cost, instant visualization of the computer results, slow line speed (300 BAUD), poor hard copy, and the early limitations on vector graphic input capabilities. The recent acquisition of the Adage 330 Graphic Display system has greatly enhanced the potential for interactive computer aided design

    Designing a comprehensive system for analysis of handwriting biomechanics in relation to neuromotor control of handwriting

    Get PDF
    A comprehensive system for investigation of biomechanical and neuromuscular processes involved with producing handwriting and drawing was developed. The system included a pen-like grip measuring device that enabled the variations of finger grip force associated with writing and drawing to be measured while holding the pen in tripod grip. The pen was integrated with a digitiser tablet for recording x,ycoordinates and pressure of the nib and a motion analysis system for recording the limb and hand kinematics. It was observed that for line drawing in the y-direction of the tablet, finger forces were directly related to pen tip movement and finger forces were modulated in a repeatable and predictable fashion, while this was not the case for line drawing in the x-direction. This was evidence for longstanding assumptions. Wrist rotation was required for production of lines in the x-direction without excessive deviation. For writing tasks, it was observed that no two tasks performed by one subject share an identical writing process, not even when the writing results are (nearly) identical. The neuromuscular control apparatus is highly flexible and works in a coordinated fashion that allows production of nearly equal end-results by means of different mechanical and therefore neuromuscular processes. For spiral drawing, tremor that originates from the fingers, hand and arm was quantified with the transducer pen. Limb joint kinematics were displayed in three dimensions with colour coding of coordinate sample numbers. This method can reveal the origin of some forms of limb tremor. Pen grip force patterns during signature writing were found to be characteristic for subjects, which relate to their individual pen-hand interaction, resulting from fine control of distal joints. Variation between trials of the same subject was observed, revealing adaptations of the computational processes during writing. The potential for signature verification by means of finger force recording was explored.A comprehensive system for investigation of biomechanical and neuromuscular processes involved with producing handwriting and drawing was developed. The system included a pen-like grip measuring device that enabled the variations of finger grip force associated with writing and drawing to be measured while holding the pen in tripod grip. The pen was integrated with a digitiser tablet for recording x,ycoordinates and pressure of the nib and a motion analysis system for recording the limb and hand kinematics. It was observed that for line drawing in the y-direction of the tablet, finger forces were directly related to pen tip movement and finger forces were modulated in a repeatable and predictable fashion, while this was not the case for line drawing in the x-direction. This was evidence for longstanding assumptions. Wrist rotation was required for production of lines in the x-direction without excessive deviation. For writing tasks, it was observed that no two tasks performed by one subject share an identical writing process, not even when the writing results are (nearly) identical. The neuromuscular control apparatus is highly flexible and works in a coordinated fashion that allows production of nearly equal end-results by means of different mechanical and therefore neuromuscular processes. For spiral drawing, tremor that originates from the fingers, hand and arm was quantified with the transducer pen. Limb joint kinematics were displayed in three dimensions with colour coding of coordinate sample numbers. This method can reveal the origin of some forms of limb tremor. Pen grip force patterns during signature writing were found to be characteristic for subjects, which relate to their individual pen-hand interaction, resulting from fine control of distal joints. Variation between trials of the same subject was observed, revealing adaptations of the computational processes during writing. The potential for signature verification by means of finger force recording was explored
    • …
    corecore