Power Management Techniques for Data Centers: A Survey
With growing use of internet and exponential growth in amount of data to be
stored and processed (known as 'big data'), the size of data centers has
greatly increased. This, however, has resulted in significant increase in the
power consumption of the data centers. For this reason, managing power
consumption of data centers has become essential. In this paper, we highlight
the need of achieving energy efficiency in data centers and survey several
recent architectural techniques designed for power management of data centers.
We also present a classification of these techniques based on their
characteristics. This paper aims to provide insights into the techniques for
improving energy efficiency of data centers and encourage the designers to
invent novel solutions for managing the large power dissipation of data
centers.Comment: Keywords: Data Centers, Power Management, Low-power Design, Energy
Efficiency, Green Computing, DVFS, Server Consolidatio
TimeTrader: Exploiting Latency Tail to Save Datacenter Energy for On-line Data-Intensive Applications
Datacenters running on-line, data-intensive applications (OLDIs) consume
significant amounts of energy. However, reducing their energy is challenging
due to their tight response time requirements. A key aspect of OLDIs is that
each user query goes to all or many of the nodes in the cluster, so that the
overall time budget is dictated by the tail of the replies' latency
distribution; replies see latency variations both in the network and compute.
Previous work proposes to achieve load-proportional energy by slowing down the
computation at lower datacenter loads based directly on response times (i.e.,
at lower loads, the proposal exploits the average slack in the time budget
provisioned for the peak load). In contrast, we propose TimeTrader to reduce
energy by exploiting the latency slack in the sub- critical replies which
arrive before the deadline (e.g., 80% of replies are 3-4x faster than the
tail). This slack is present at all loads and subsumes the previous work's
load-related slack. While the previous work shifts the leaves' response time
distribution to consume the slack at lower loads, TimeTrader reshapes the
distribution at all loads by slowing down individual sub-critical nodes without
increasing missed deadlines. TimeTrader exploits slack in both the network and
compute budgets. Further, TimeTrader leverages Earliest Deadline First
scheduling to largely decouple critical requests from the queuing delays of
sub- critical requests which can then be slowed down without hurting critical
requests. A combination of real-system measurements and at-scale simulations
shows that without adding to missed deadlines, TimeTrader saves 15-19% and
41-49% energy at 90% and 30% loading, respectively, in a datacenter with 512
nodes, whereas previous work saves 0% and 31-37%.Comment: 13 page
A Genetic Algorithm for Power-Aware Virtual Machine Allocation in Private Cloud
Energy efficiency has become an important measurement of scheduling algorithm
for private cloud. The challenge is trade-off between minimizing of energy
consumption and satisfying Quality of Service (QoS) (e.g. performance or
resource availability on time for reservation request). We consider resource
needs in context of a private cloud system to provide resources for
applications in teaching and researching. In which users request computing
resources for laboratory classes at start times and non-interrupted duration in
some hours in prior. Many previous works are based on migrating techniques to
move online virtual machines (VMs) from low utilization hosts and turn these
hosts off to reduce energy consumption. However, the techniques for migration
of VMs could not use in our case. In this paper, a genetic algorithm for
power-aware in scheduling of resource allocation (GAPA) has been proposed to
solve the static virtual machine allocation problem (SVMAP). Due to limited
resources (i.e. memory) for executing simulation, we created a workload that
contains a sample of one-day timetable of lab hours in our university. We
evaluate the GAPA and a baseline scheduling algorithm (BFD), which sorts list
of virtual machines in start time (i.e. earliest start time first) and using
best-fit decreasing (i.e. least increased power consumption) algorithm, for
solving the same SVMAP. As a result, the GAPA algorithm obtains total energy
consumption is lower than the baseline algorithm on simulated experimentation.Comment: 10 page
Computing server power modeling in a data center: survey,taxonomy and performance evaluation
Data centers are large scale, energy-hungry infrastructure serving the
increasing computational demands as the world is becoming more connected in
smart cities. The emergence of advanced technologies such as cloud-based
services, internet of things (IoT) and big data analytics has augmented the
growth of global data centers, leading to high energy consumption. This upsurge
in energy consumption of the data centers not only incurs the issue of surging
high cost (operational and maintenance) but also has an adverse effect on the
environment. Dynamic power management in a data center environment requires the
cognizance of the correlation between the system and hardware level performance
counters and the power consumption. Power consumption modeling exhibits this
correlation and is crucial in designing energy-efficient optimization
strategies based on resource utilization. Several works in power modeling are
proposed and used in the literature. However, these power models have been
evaluated using different benchmarking applications, power measurement
techniques and error calculation formula on different machines. In this work,
we present a taxonomy and evaluation of 24 software-based power models using a
unified environment, benchmarking applications, power measurement technique and
error formula, with the aim of achieving an objective comparison. We use
different servers architectures to assess the impact of heterogeneity on the
models' comparison. The performance analysis of these models is elaborated in
the paper
Adaptive runtime techniques for power and resource management on multi-core systems
Energy-related costs are among the major contributors to the total cost of ownership of data centers and high-performance computing (HPC) clusters. As a result, future data centers must be energy-efficient to meet the continuously increasing computational demand. Constraining the power consumption of the servers is a widely used approach for managing energy costs and complying with power delivery limitations. In tandem, virtualization has become a common practice, as virtualization reduces hardware and power requirements by enabling consolidation of multiple applications on to a smaller set of physical resources. However, administration and management of data center resources have become more complex due to the growing number of virtualized servers installed in data centers. Therefore, designing autonomous and adaptive energy efficiency approaches is crucial to achieve sustainable and cost-efficient operation in data centers.
Many modern data centers running enterprise workloads successfully implement energy efficiency approaches today. However, the nature of multi-threaded applications, which are becoming more common in all computing domains, brings additional design and management challenges. Tackling these challenges requires a deeper understanding of the interactions between the applications and the underlying hardware nodes. Although cluster-level management techniques bring significant benefits, node-level techniques provide more visibility into application characteristics, which can then be used to further improve the overall energy efficiency of the data centers.
This thesis proposes adaptive runtime power and resource management techniques on multi-core systems. It demonstrates that taking the multi-threaded workload characteristics into account during management significantly improves the energy efficiency of the server nodes, which are the basic building blocks of data centers. The key distinguishing features of this work are as follows:
We implement the proposed runtime techniques on state-of-the-art commodity multi-core servers and show that their energy efficiency can be significantly improved by (1) taking multi-threaded application specific characteristics into account while making resource allocation decisions, (2) accurately tracking dynamically changing power constraints by using low-overhead application-aware runtime techniques, and (3) coordinating dynamic adaptive decisions at various layers of the computing stack, specifically at system and application levels. Our results show that efficient resource distribution under power constraints yields energy savings of up to 24% compared to existing approaches, along with the ability to meet power constraints 98% of the time for a diverse set of multi-threaded applications
Architecting Efficient Data Centers.
Data center power consumption has become a key constraint in continuing to scale Internet services. As our society’s reliance on “the Cloud” continues to grow, companies require an ever-increasing amount of computational capacity to support their customers. Massive warehouse-scale data centers have emerged, requiring 30MW or more of total power capacity. Over the lifetime of a typical high-scale data center, power-related costs make up 50% of the total cost of ownership (TCO). Furthermore, the aggregate effect of data center power consumption across the country cannot be ignored. In total, data center energy usage has reached approximately 2% of aggregate consumption in the United States and continues to grow.
This thesis addresses the need to increase computational efficiency to address this grow- ing problem. It proposes a new classes of power management techniques: coordinated full-system idle low-power modes to increase the energy proportionality of modern servers. First, we introduce the PowerNap server architecture, a coordinated full-system idle low- power mode which transitions in and out of an ultra-low power nap state to save power during brief idle periods. While effective for uniprocessor systems, PowerNap relies on full-system idleness and we show that such idleness disappears as the number of cores per processor continues to increase. We expose this problem in a case study of Google Web search in which we demonstrate that coordinated full-system active power modes are necessary to reach energy proportionality and that PowerNap is ineffective because of a lack of idleness. To recover full-system idleness, we introduce DreamWeaver, architectural support for deep sleep. DreamWeaver allows a server to exchange latency for full-system idleness, allowing PowerNap-enabled servers to be effective and provides a better latency- power savings tradeoff than existing approaches. Finally, this thesis investigates workloads which achieve efficiency through methodical cluster provisioning techniques. Using the popular memcached workload, this thesis provides examples of provisioning clusters for cost-efficiency given latency, throughput, and data set size targets.Ph.D.Computer Science & EngineeringUniversity of Michigan, Horace H. Rackham School of Graduate Studieshttp://deepblue.lib.umich.edu/bitstream/2027.42/91499/1/meisner_1.pd
Datacenter Traffic Control: Understanding Techniques and Trade-offs
Datacenters provide cost-effective and flexible access to scalable compute
and storage resources necessary for today's cloud computing needs. A typical
datacenter is made up of thousands of servers connected with a large network
and usually managed by one operator. To provide quality access to the variety
of applications and services hosted on datacenters and maximize performance, it
deems necessary to use datacenter networks effectively and efficiently.
Datacenter traffic is often a mix of several classes with different priorities
and requirements. This includes user-generated interactive traffic, traffic
with deadlines, and long-running traffic. To this end, custom transport
protocols and traffic management techniques have been developed to improve
datacenter network performance.
In this tutorial paper, we review the general architecture of datacenter
networks, various topologies proposed for them, their traffic properties,
general traffic control challenges in datacenters and general traffic control
objectives. The purpose of this paper is to bring out the important
characteristics of traffic control in datacenters and not to survey all
existing solutions (as it is virtually impossible due to massive body of
existing research). We hope to provide readers with a wide range of options and
factors while considering a variety of traffic control mechanisms. We discuss
various characteristics of datacenter traffic control including management
schemes, transmission control, traffic shaping, prioritization, load balancing,
multipathing, and traffic scheduling. Next, we point to several open challenges
as well as new and interesting networking paradigms. At the end of this paper,
we briefly review inter-datacenter networks that connect geographically
dispersed datacenters which have been receiving increasing attention recently
and pose interesting and novel research problems.Comment: Accepted for Publication in IEEE Communications Surveys and Tutorial
Recommended from our members
Energy Agile Cluster Communication
Computing researchers have long focused on improving energy-efficiency?the amount of computation per joule? under the implicit assumption that all energy is created equal. Energy however is not created equal: its cost and carbon footprint fluctuates over time due to a variety of factors. These fluctuations are expected to in- tensify as renewable penetration increases. Thus in my work I introduce energy-agility a design concept for a platform?s ability to rapidly and efficiently adapt to such power fluctuations. I then introduce a representative application to assess energy-agility for the type of long-running, parallel, data-intensive tasks that are both common in data centers and most amenable to delays from variations in available power. Multiple variants of the application are implemented to illustrate the fundamental tradeoffs in designing energy-agile parallel applications. I find that with inactive power state transition latencies of up to 15 seconds, a design that regularly ”blinks” servers out- performs one that minimizes transitions by only changing power states when power varies. While the latter approach has much lower transition overhead, it requires additional I/O, since servers are not always concurrently active. Unfortunately, I find that most server-class platforms today are not energy-agile: they have transition la- tencies beyond one minute, forcing them to minimize transition and incur additional I/O
- …