3,723 research outputs found
Optimization of measurement configurations for geometrical calibration of industrial robot
The paper is devoted to the geometrical calibration of industrial robots
employed in precise manufacturing. To identify geometric parameters, an
advanced calibration technique is proposed that is based on the non-linear
experiment design theory, which is adopted for this particular application. In
contrast to previous works, the calibration experiment quality is evaluated
using a concept of the user-defined test-pose. In the frame of this concept,
the related optimization problem is formulated and numerical routines are
developed, which allow user to generate optimal set of manipulator
configurations for a given number of calibration experiments. The efficiency of
the developed technique is illustrated by several examples.Comment: arXiv admin note: text overlap with arXiv:1211.610
Design of Calibration Experiments for Identification of Manipulator Elastostatic Parameters
The paper is devoted to the elastostatic calibration of industrial robots,
which is used for precise machining of large-dimensional parts made of
composite materials. In this technological process, the interaction between the
robot and the workpiece causes essential elastic deflections of the manipulator
components that should be compensated by the robot controller using relevant
elastostatic model of this mechanism. To estimate parameters of this model, an
advanced calibration technique is applied that is based on the non-linear
experiment design theory, which is adopted for this particular application. In
contrast to previous works, it is proposed a concept of the user-defined
test-pose, which is used to evaluate the calibration experiments quality. In
the frame of this concept, the related optimization problem is defined and
numerical routines are developed, which allow generating optimal set of
manipulator configurations and corresponding forces/torques for a given number
of the calibration experiments. Some specific kinematic constraints are also
taken into account, which insure feasibility of calibration experiments for the
obtained configurations and allow avoiding collision between the robotic
manipulator and the measurement equipment. The efficiency of the developed
technique is illustrated by an application example that deals with elastostatic
calibration of the serial manipulator used for robot-based machining.Comment: arXiv admin note: substantial text overlap with arXiv:1211.573
Modelling of the gravity compensators in robotic manufacturing cells
The paper deals with the modeling and identification of the gravity
compensators used in heavy industrial robots. The main attention is paid to the
geometrical parameters identification and calibration accuracy. To reduce
impact of the measurement errors, the design of calibration experiments is
used. The advantages of the developed technique are illustrated by experimental
result
Identification of geometrical and elastostatic parameters of heavy industrial robots
The paper focuses on the stiffness modeling of heavy industrial robots with
gravity compensators. The main attention is paid to the identification of
geometrical and elastostatic parameters and calibration accuracy. To reduce
impact of the measurement errors, the set of manipulator configurations for
calibration experiments is optimized with respect to the proposed performance
measure related to the end-effector position accuracy. Experimental results are
presented that illustrate the advantages of the developed technique.Comment: arXiv admin note: substantial text overlap with arXiv:1311.667
Robust algorithm for calibration of robotic manipulator model
The paper focuses on the robust identification of geometrical and elastostatic parameters of robotic manipulator. The main attention is paid to the efficiency improvement of the identification algorithm. To increase the identification accuracy, it is proposed to apply the weighted least square technique that employs a new algorithm for assigning of the weighting coefficients. The latter allows taking into account variation of the measurement system precision in different directions and throughout the robot workspace. The advantages of the proposed approach are illustrated by an application example that deals with the elasto-static calibration of industrial robot.AN
Efficiency Improvement of Measurement Pose Selection Techniques in Robot Calibration
The paper deals with the design of experiments for manipulator geometric and
elastostatic calibration based on the test-pose approach. The main attention is
paid to the efficiency improvement of numerical techniques employed in the
selection of optimal measurement poses for calibration experiments. The
advantages of the developed technique are illustrated by simulation examples
that deal with the geometric calibration of the industrial robot of serial
architecture
Design of Experiments for Calibration of Planar Anthropomorphic Manipulators
The paper presents a novel technique for the design of optimal calibration
experiments for a planar anthropomorphic manipulator with n degrees of freedom.
Proposed approach for selection of manipulator configurations allows
essentially improving calibration accuracy and reducing parameter
identification errors. The results are illustrated by application examples that
deal with typical anthropomorphic manipulators.Comment: Advanced Intelligent Mechatronics (AIM), 2011 IEEE/ASME International
Conference on, Budapest : Hungary (2011
Design of Calibration Experiments for Identification of Manipulator Elastostatic Parameters
International audienceThe paper is devoted to the elastostatic calibration of industrial robots, which is used for precise machining of large-dimensional parts made of composite materials. In this technological process, the interaction between the robot and the workpiece causes essential elastic deflections of the manipulator components that should be compensated by the robot controller using relevant elastostatic model of this mechanism. To estimate parameters of this model, an advanced calibration technique is applied that is based on the non-linear experiment design theory, which is adopted for this particular application. In contrast to previous works, it is proposed a concept of the user-defined test-pose, which is used to evaluate the calibration experiments quality. In the frame of this concept, the related optimization problem is defined and numerical routines are developed, which allow generating optimal set of manipulator configurations and corresponding forces/torques for a given number of the calibration experiments. Some specific kinematic constraints are also taken into account, which insure feasibility of calibration experiments for the obtained configurations and allow avoiding collision between the robotic manipulator and the measurement equipment. The efficiency of the developed technique is illustrated by an application example that deals with elastostatic calibration of the serial manipulator used for robot-based machining
Advanced robot calibration using partial pose measurements
International audienceThe paper focuses on the calibration of serial industrial robots using partial pose measurements. In contrast to other works, the developed advanced robot calibration technique is suitable for geometrical and elastostatic calibration. The main attention is paid to the model parameters identification accuracy. To reduce the impact of measurement errors, it is proposed to use directly position measurements of several points instead of computing orientation of the end-effector. The proposed approach allows us to avoid the problem of non-homogeneity of the least-square objective, which arises in the classical identification technique with the full-pose information. The developed technique does not require any normalization and can be efficiently applied both for geometric and elastostatic identification. The advantages of a new approach are confirmed by comparison analysis that deals with the efficiency evaluation of different identification strategies. The obtained results have been successfully applied to the elastostatic parameters identification of the industrial robot employed in a machining work-cell for aerospace industry
Geometric and elastostatic calibration of robotic manipulator using partial pose measurements
International audienceThe paper deals with geometric and elastostatic calibration of robotic manipulator using partial pose measurements, which do not provide the end-effector orientation. The main attention is paid to the efficiency improvement of identification procedure. In contrast to previous works, the developed calibration technique is based on the direct measurements only. To improve the identification accuracy, it is proposed to use several reference points for each manipulator configuration. This allows avoiding the problem of non-homogeneity of the least-square objective, which arises in the classical identification technique with the full-pose information (position and orientation). Its efficiency is confirmed by the comparison analysis, which deals with the accuracy evaluation of different identification strategies. The obtained theoretical results have been successfully applied to the geometric and elastostatic calibration of serial industrial robot employed in a machining work-cell for aerospace industry
- …