7,442 research outputs found

    Technical innovation changes standard radiographic protocols in veterinary medicine: is it necessary to obtain two dorsoproximal-palmarodistal oblique views of the equine foot when using computerised radiography systems?

    Get PDF
    Since the 1950s, veterinary practitioners have included two separate dorsoproximal–palmarodistal oblique (DPr–PaDiO) radiographs as part of a standard series of the equine foot. One image is obtained to visualise the distal phalanx and the other to visualise the navicular bone. However, rapid development of computed radiography and digital radiography and their post-processing capabilities could mean that this practice is no longer required. The aim of this study was to determine differences in perceived image quality between DPr–PaDiO radiographs that were acquired with a computerised radiography system with exposures, centring and collimation recommended for the navicular bone versus images acquired for the distal phalanx but were subsequently manipulated post-acquisition to highlight the navicular bone. Thirty images were presented to four clinicians for quality assessment and graded using a 1–3 scale (1=textbook quality, 2=diagnostic quality, 3=non-diagnostic image). No significant difference in diagnostic quality was found between the original navicular bone images and the manipulated distal phalanx images. This finding suggests that a single DPr–PaDiO image of the distal phalanx is sufficient for an equine foot radiographic series, with appropriate post-processing and manipulation. This change in protocol will result in reduced radiographic study time and decreased patient/personnel radiation exposure

    Radiographic applications of spatial frequency multiplexing

    Get PDF
    The application of spacial frequency encoding techniques which allow different regions of the X-ray spectrum to be encoded on conventional radiographs was studied. Clinical considerations were reviewed, as were experimental studies involving the encoding and decoding of X-ray images at different energies and the subsequent processing of the data to produce images of specific materials in the body

    Diagnosing and mapping pulmonary emphysema on X-ray projection images

    Get PDF
    To assess whether grating-based X-ray dark-field imaging can increase the sensitivity of X-ray projection images in the diagnosis of pulmonary emphysema and allow for a more accurate assessment of emphysema distribution. Lungs from three mice with pulmonary emphysema and three healthy mice were imaged ex vivo using a laser-driven compact synchrotron X-ray source. Median signal intensities of transmission (T), dark-field (V) and a combined parameter (normalized scatter) were compared between emphysema and control group. To determine the diagnostic value of each parameter in differentiating between healthy and emphysematous lung tissue, a receiver-operating-characteristic (ROC) curve analysis was performed both on a per-pixel and a per-individual basis. Parametric maps of emphysema distribution were generated using transmission, dark-field and normalized scatter signal and correlated with histopathology. Transmission values relative to water were higher for emphysematous lungs than for control lungs (1.11 vs. 1.06, p<0.001). There was no difference in median dark-field signal intensities between both groups (0.66 vs. 0.66). Median normalized scatter was significantly lower in the emphysematous lungs compared to controls (4.9 vs. 10.8, p<0.001), and was the best parameter for differentiation of healthy vs. emphysematous lung tissue. In a per-pixel analysis, the area under the ROC curve (AUC) for the normalized scatter value was significantly higher than for transmission (0.86 vs. 0.78, p<0.001) and dark-field value (0.86 vs. 0.52, p<0.001) alone. Normalized scatter showed very high sensitivity for a wide range of specificity values (94% sensitivity at 75% specificity). Using the normalized scatter signal to display the regional distribution of emphysema provides color-coded parametric maps, which show the best correlation with histopathology. In a murine model, the complementary information provided by X-ray transmission and dark-field images adds incremental diagnostic value in detecting pulmonary emphysema and visualizing its regional distribution as compared to conventional X-ray projections

    Methods of visualisation

    Get PDF

    PadChest: A large chest x-ray image dataset with multi-label annotated reports

    Get PDF
    We present a labeled large-scale, high resolution chest x-ray dataset for the automated exploration of medical images along with their associated reports. This dataset includes more than 160,000 images obtained from 67,000 patients that were interpreted and reported by radiologists at Hospital San Juan Hospital (Spain) from 2009 to 2017, covering six different position views and additional information on image acquisition and patient demography. The reports were labeled with 174 different radiographic findings, 19 differential diagnoses and 104 anatomic locations organized as a hierarchical taxonomy and mapped onto standard Unified Medical Language System (UMLS) terminology. Of these reports, 27% were manually annotated by trained physicians and the remaining set was labeled using a supervised method based on a recurrent neural network with attention mechanisms. The labels generated were then validated in an independent test set achieving a 0.93 Micro-F1 score. To the best of our knowledge, this is one of the largest public chest x-ray database suitable for training supervised models concerning radiographs, and the first to contain radiographic reports in Spanish. The PadChest dataset can be downloaded from http://bimcv.cipf.es/bimcv-projects/padchest/

    Computed vs. film-based radiographs' contour artifacts influence diagnosis of secondary caries.

    Get PDF
    To test local grey-scale changes on dental bitewing radiographs near filling margins for image acquisition. Forty approximal preparations in caries-free amalgam filled teeth and bitewing radiographs were acquired under standardized conditions applying four techniques. Film-based analog radiographs were digitized using flat-bed scanner (FDR). Phosphor-plate computed radiographs (PCR) were directly acquired by scanning VistaScan imaging plates. Image quality was tested using Preset Filter (PF) or manually applied IntraOral Fine Filter (IF) to enhance digital images. Local changes from digital imaging processing were assessed by comparing the margin-near (MN) and margin-far (MF) zone by a multivariate repeated measurements analysis. All images were acquired with 8-bit depth (256 shades). Dentine was displayed in 79 shades for FDR and 54 shades for PCR. PF or IF locally modify bitewing radiographs by darkening marginal dentine by 8 or 29 shades, respectively. The sharpest display of the margin (shades per pixel) from dentine to filling was found for IF (26.2), followed by FDR (23.2), PF (15.3) and PCR (8.3). Computed radiography with phosphor plates generate more homogeneous images compared to flatbed-digitized film-based radiographs. The filling margin was sharpest represented with the IF filter at the detriment of an artificial darkening of the dentine near the margin of the filling. Contour artifacts by filters have the potential to confound diagnosis of secondary caries. Algorithms and filters for sensor data processing, causing local changes above 2% of the dynamic range by non-continuous mathematical functions, should only be applied with caution, manually when diagnosing and reversibly

    Aerospace Medicine and Biology. A continuing bibliography with indexes

    Get PDF
    This bibliography lists 244 reports, articles, and other documents introduced into the NASA scientific and technical information system in February 1981. Aerospace medicine and aerobiology topics are included. Listings for physiological factors, astronaut performance, control theory, artificial intelligence, and cybernetics are included

    Virtual Reality applied to biomedical engineering

    Get PDF
    Actualment, la realitat virtual esta sent tendència i s'està expandint a l'àmbit mèdic, fent possible l'aparició de nombroses aplicacions dissenyades per entrenar metges i tractar pacients de forma més eficient, així com optimitzar els processos de planificació quirúrgica. La necessitat mèdica i objectiu d'aquest projecte és fer òptim el procés de planificació quirúrgica per a cardiopaties congènites, que compren la reconstrucció en 3D del cor del pacient i la seva integració en una aplicació de realitat virtual. Seguint aquesta línia s’ha combinat un procés de modelat 3D d’imatges de cors obtinguts gracies al Hospital Sant Joan de Déu i el disseny de l’aplicació mitjançant el software Unity 3D gracies a l’empresa VISYON. S'han aconseguit millores en quant al software emprat per a la segmentació i reconstrucció, i s’han assolit funcionalitats bàsiques a l’aplicació com importar, moure, rotar i fer captures de pantalla en 3D de l'òrgan cardíac i així, entendre millor la cardiopatia que s’ha de tractar. El resultat ha estat la creació d'un procés òptim, en el que la reconstrucció en 3D ha aconseguit ser ràpida i precisa, el mètode d’importació a l’app dissenyada molt senzill, i una aplicació que permet una interacció atractiva i intuïtiva, gracies a una experiència immersiva i realista per ajustar-se als requeriments d'eficiència i precisió exigits en el camp mèdic

    New technology in radiological diagnosis: An investigation of diagnostic image quality in digital displays of radiographs

    Get PDF
    Digital radiology is undergoing rapid evolution. Its objectives can be summarized as the creation within the modern radiology department - and indeed within the entire hospital - of a harmonious, integrated, electronic network capable of handling all diagnostic radiological images, obviating the need for conventional film-based radiology. One of the limiting factors in the introduction and exploitation of digital technology is the issue of image display quality: if electronic display systems are to be widely used for primary radiological diagnosis, it is essential that the diagnostic quality of the displayed images should not be compromised. From the perspective of the practising radiologist, this study examines the performance of the first two commercially available digital radiological display systems to be purchased and installed in a British hospital. This work incorporates an extensive observer performance investigation of image quality from existing 1024- and 1280-line display systems, and suggests that displayed images digitized at a pixel size of 210?m show a significant reduction in diagnostic performance when compared with original film. Such systems appear to be unsuitable for primary radiological diagnosis of subtle lesions. Some of the physical properties of such systems, some relevant methodological issues, and the relationship between image quality and other factors influencing the development acceptance and implementation of digital technology, have also been investigated; the results are presented. This is a controversial subject, and conflicting views have been expressed in the British literature concerning the issue of whether or not the technology is now ready for total system implementation; the view of this author is that careful testing of display systems, and of every other component of digital networks, should precede their entry into clinical use

    Overview of the 2005 cross-language image retrieval track (ImageCLEF)

    Get PDF
    The purpose of this paper is to outline efforts from the 2005 CLEF crosslanguage image retrieval campaign (ImageCLEF). The aim of this CLEF track is to explore the use of both text and content-based retrieval methods for cross-language image retrieval. Four tasks were offered in the ImageCLEF track: a ad-hoc retrieval from an historic photographic collection, ad-hoc retrieval from a medical collection, an automatic image annotation task, and a user-centered (interactive) evaluation task that is explained in the iCLEF summary. 24 research groups from a variety of backgrounds and nationalities (14 countries) participated in ImageCLEF. In this paper we describe the ImageCLEF tasks, submissions from participating groups and summarise the main fndings
    • …
    corecore