316 research outputs found

    Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation

    Get PDF
    This paper introduces a newly developed gait rehabilitation device. The device, called LOPES, combines a freely translatable and 2-D-actuated pelvis segment with a leg exoskeleton containing three actuated rotational joints: two at the hip and one at the knee. The joints are impedance controlled to allow bidirectional mechanical interaction between the robot and the training subject. Evaluation measurements show that the device allows both a "pa- tient-in-charge" and "robot-in-charge" mode, in which the robot is controlled either to follow or to guide a patient, respectively. Electromyography (EMG) measurements (one subject) on eight important leg muscles, show that free walking in the device strongly resembles free treadmill walking; an indication that the device can offer task-specific gait training. The possibilities and limitations to using the device as gait measurement tool are also shown at the moment position measurements are not accurate enough for inverse-dynamical gait analysis

    Analysis of the human interaction with a wearable lower-limb exoskeleton

    Get PDF
    The design of a wearable robotic exoskeleton needs to consider the interaction, either physical or cognitive, between the human user and the robotic device. This paper presents a method to analyse the interaction between the human user and a unilateral, wearable lower-limb exoskeleton. The lower-limb exoskeleton function was to compensate for muscle weakness around the knee joint. It is shown that the cognitive interaction is bidirectional; on the one hand, the robot gathered information from the sensors in order to detect human actions, such as the gait phases, but the subjects also modified their gait patterns to obtain the desired responses from the exoskeleton. The results of the two-phase evaluation of learning with healthy subjects and experiments with a patient case are presented, regarding the analysis of the interaction, assessed in terms of kinematics, kinetics and/or muscle recruitment. Human-driven response of the exoskeleton after training revealed the improvements in the use of the device, while particular modifications of motion patterns were observed in healthy subjects. Also, endurance (mechanical) tests provided criteria to perform experiments with one post-polio patient. The results with the post-polio patient demonstrate the feasibility of providing gait compensation by means of the presented wearable exoskeleton, designed with a testing procedure that involves the human users to assess the human-robot interaction

    Novel Design and Implementation of a Knee Exoskeleton for Gait Rehabilitation with Impedance Control Strategy

    Get PDF
    This paper presents a novel cable-driven robotic joint for a gait exoskeleton robot. We discussed in detail a lightweight, low inertia, and highly back-drivable, 1-DOF tension amplification mechanism based on a pulley system and block-and-tackle technique. The exoskeleton is controlled using an impedance controller under the active-assistive and resistive approaches. Four experiments were conducted to evaluate the proposed exoskeleton’s safety and controller performance: mechanical transparency analysis, active-assistive trajectory tracking, resistance of trajectory tracking, and gait rehabilitation. The exoskeleton demonstrated high transparency with the root mean square (RMS) torque of 0.457 Nm under no-load condition, suggesting that the mechanism is highly back-drivable, has a low moment of inertia, and is mechanically safe to operate. The active-assistive trajectory tracking experiment indicated that the output torque was generated under assist-as-needed approach, as the average robotic-assistance torque was lowered by more than 73% when the user provided assistance force to complete the task on their own.  Additionally, the resistance experiment revealed the feasibility of employing the exoskeleton to strengthen muscles with adjustable resistive torque from 0.94 Nm and 2.25 Nm. Finally, the result of gait rehabilitation experiment demonstrated that the robot was able to provide adequate torque to assist users in completing their gait cycle without causing any negative effects during or after the experiment

    A 1-DOF Assistive exoskeleton with virtual negative damping: Effects on the kinematic response of the lower limbs

    Full text link
    We propose a novel control method for lowerlimb assist that produces a virtual modification of the mechanical impedance of the human limbs. This effect is accomplished through the use of an exoskeleton that displays active impedance. The proposed method is aimed at improving the dynamic response of the human limbs, while preserving the user's control authority. Our goal is to use active-impedance exoskeleton control to improve the user's agility of motion, for example by reducing the average time needed to complete a movement. Our control method has been implemented in a 1-DOF exoskeleton designed to assist human subjects performing knee flexions and extensions. In this paper we discuss an initial study on the effect of negative exoskeleton damping (a particular case of active-impedance control) on the subject's time to complete a target-reaching motion. Experimental results show this effect to be statistically significant. On average, subjects were able to reduce the time to complete the motion by 16%

    Mechanical Design and Kinematic Modeling of a Cable-Driven Arm Exoskeleton Incorporating Inaccurate Human Limb Anthropomorphic Parameters

    Get PDF
    Compared with conventional exoskeletons with rigid links, cable-driven upper-limb exoskeletons are light weight and have simple structures. However, cable-driven exoskeletons rely heavily on the human skeletal system for support. Kinematic modeling and control thus becomes very challenging due to inaccurate anthropomorphic parameters and flexible attachments. In this paper, the mechanical design of a cable-driven arm rehabilitation exoskeleton is proposed to accommodate human limbs of different sizes and shapes. A novel arm cuff able to adapt to the contours of human upper limbs is designed. This has given rise to an exoskeleton which reduces the uncertainties caused by instabilities between the exoskeleton and the human arm. A kinematic model of the exoskeleton is further developed by considering the inaccuracies of human-arm skeleton kinematics and attachment errors of the exoskeleton. A parameter identification method is used to improve the accuracy of the kinematic model. The developed kinematic model is finally tested with a primary experiment with an exoskeleton prototype

    The Influence of Posture, Applied Force and Perturbation Direction on Hip Joint Viscoelasticity.

    Get PDF
    Limb viscoelasticity is a critical neuromechanical factor used to regulate the interaction with the environment. It plays a key role in modelling human sensorimotor control, and can be used to assess the condition of healthy and neurologically affected individuals. This paper reports the estimation of hip joint viscoelasticity during voluntary force control using a novel device that applies a leg displacement without constraining the hip joint. The influence of hip angle, applied limb force and perturbation direction on the stiffness and viscosity values was studied in ten subjects. No difference was detected in the hip joint stiffness between the dominant and non-dominant legs, but a small dependency was observed on the perturbation direction. Both hip stiffness and viscosity increased monotonically with the applied force magnitude, with posture being observed to have a slight influence. These results are in line with previous measurements carried out on upper limbs, and can be used as a baseline for lower limb movement simulation and further neuromechanical investigations
    corecore