4,332 research outputs found

    The application of ultrasonic NDT techniques in tribology

    Get PDF
    The use of ultrasonic reflection is emerging as a technique for studying tribological contacts. Ultrasonic waves can be transmitted non-destructively through machine components and their behaviour at an interface describes the characteristics of that contact. This paper is a review of the current state of understanding of the mechanisms of ultrasonic reflection at interfaces, and how this has been used to investigate the processes of dry rough surface contact and lubricated contact. The review extends to cover how ultrasound has been used to study the tribological function of certain engineering machine elements

    Application of ultrasound techniques to liquid-liquid dispersed flows

    Get PDF
    This paper delineates the development and application of non-intrusive diagnostic ultrasound (US) techniques for the measurement of the drop size distribution (DSD) and the drop volume fraction in dispersed liquid-liquid flows. The techniques used here are based on the measurement of the speed and the attenuation coefficient of the propagated ultrasound wave. To validate the results of the ultrasound measurements, a planar laser induced fluorescence (PLIF) technique was used to image the dispersed phase at the same time and location as the ultrasound transducers. For the tests, a silicon oil and a glycerol/water mixture, with the same refractive index as the oil, were used. The experiments were carried out in a stirred vessel with the impeller placed either just below the oil/aqueous mixture interface or at 25 mm below the interface and rotated at speeds of 300–400 rpm. The dispersed oil volume fractions measured by both the US and PLIF techniques were in excellent agreement and varied between 0.53% to 4.2%. Good agreement between the two techniques was also found for the drop size distributions. For the conditions investigated, the drop size ranged from 0.25 mm to 2 mm. The results indicated that the developed ultrasound technique is a powerful tool for characterising dispersed phases in liquid-liquid flows

    Application of acoustic techniques to fluid-particle systems – A review

    Get PDF
    Acoustic methods applied to opaque systems have attracted the attention of researchers in fluid mechanics. In particular, owing to their ability to characterise in real-time, non-transparent and highly concentrated fluid-particle systems, they have been applied to the study of complex multiphase flows such as fluidised beds. This paper gives an overview of the physical principles and typical challenges of ultrasound and acoustic emission AE methods when applied to fluid-particle systems. The principles of ultrasound imaging are explained first. The measurement techniques and signal processing methodologies for obtaining velocity profiles, size distribution of the dispersed phases, and solid volume fraction are then discussed. The techniques are based on the measurement of attenuation, sound speed, frequency shift, and transit time of the propagated sound wave. A description of the acoustic emission technique and applications to fluid-particle systems are then discussed. Finally, extensions and future opportunities of the acoustic techniques are presented

    Composition measurements of crude oil and process water emulsions using thick-film ultrasonic transducers

    No full text
    This paper presents an experimental study to investigate the suitability of thick-film ultrasonic transducers for composition measurements in heterogeneous mixtures. Following on from earlier developments [G. Meng, A.J. Jaworski, T. Dyakowski, J.M. Hale, N.M. White, Design and testing of a thick-film dual-modality sensor for composition measurements in heterogeneous mixtures, Meas. Sci. Technol. 16(4) (2005) 942–954], focused on the design and preliminary testing of the transducers for mixtures of vegetable oil and salty water, the current paper looks in more detail into their application to industrially relevant fluids, namely crude oil and process water, which are common in oil and gas extraction and petrochemical industries. The measurements are based on the time-of-flight of the ultrasonic pressure wave in order to obtain the speed of sound. The results, showing the variation of the speed of sound with the volume fraction of crude oil, for three different temperatures, are compared with five theoretical models available in the existing literature. It is shown that the models proposed by Urick [R.J. Urick, A sound velocity method for determining the compressibility of finely divided substances, J. Appl. Phys. 18 (1947) 983–987] and by Kuster and Toks¹oz [G.T. Kuster, M.N. Toks¹oz, Velocity and attenuation of seismic waves in two-phase media. Part I. Theoretical formulations, Geophysics 39 (1974) 587–606] provide a relatively accurate prediction for the speed of sound in the media studied. Interestingly, the model developed by Povey and co-workers [V.J. Pinfield, M.J.W. Povey, Thermal scattering must be accounted for in the determination of adiabatic compressibility, J. Phys. Chem. B 101 (1997) 1110–1112] only agrees with experiment when its thermal scattering features are neglected. Overall, the results obtained demonstrate that the slim-line and compact thick-film transducers can be considered as a viable means for the composition measurements in the process conditions

    Ultrasound-Assisted CO2 Flooding to Improve Oil Recovery

    Get PDF
    The authors would like to gratefully acknowledge and appreciate the School of Engineering, University of Aberdeen, Aberdeen, Scotland, United Kingdom, for the provision of the laboratory facilities necessary for completing this work.Peer reviewedPostprin

    Experimental investigations of two-phase flow measurement using ultrasonic sensors

    Get PDF
    This thesis presents the investigations conducted in the use of ultrasonic technology to measure two-phase flow in both horizontal and vertical pipe flows which is important for the petroleum industry. However, there are still key challenges to measure parameters of the multiphase flow accurately. Four methods of ultrasonic technologies were explored. The Hilbert-Huang transform (HHT) was first applied to the ultrasound signals of air-water flow on horizontal flow for measurement of the parameters of the two- phase slug flow. The use of the HHT technique is sensitive enough to detect the hydrodynamics of the slug flow. The results of the experiments are compared with correlations in the literature and are in good agreement. Next, experimental data of air-water two-phase flow under slug, elongated bubble, stratified-wavy and stratified flow regimes were used to develop an objective flow regime classification of two-phase flow using the ultrasonic Doppler sensor and artificial neural network (ANN). The classifications using the power spectral density (PSD) and discrete wavelet transform (DWT) features have accuracies of 87% and 95.6% respectively. This is considerably more promising as it uses non-invasive and non-radioactive sensors. Moreover, ultrasonic pulse wave transducers with centre frequencies of 1MHz and 7.5MHz were used to measure two-phase flow both in horizontal and vertical flow pipes. The liquid level measurement was compared with the conductivity probes technique and agreed qualitatively. However, in the vertical with a gas volume fraction (GVF) higher than 20%, the ultrasound signals were attenuated. Furthermore, gas-liquid and oil-water two-phase flow rates in a vertical upward flow were measured using a combination of an ultrasound Doppler sensor and gamma densitometer. The results showed that the flow gas and liquid flow rates measured are within ±10% for low void fraction tests, water-cut measurements are within ±10%, densities within ±5%, and void fractions within ±10%. These findings are good results for a relatively fast flowing multiphase flow

    Current methods for characterising mixing and flow in microchannels

    Get PDF
    This article reviews existing methods for the characterisation of mixing and flow in microchannels, micromixers and microreactors. In particular, it analyses the current experimental techniques and methods available for characterising mixing and the associated phenomena in single and multiphase flow. The review shows that the majority of the experimental techniques used for characterising mixing and two-phase flow in microchannels employ optical methods, which require optical access to the flow, or off-line measurements. Indeed visual measurements are very important for the fundamental understanding of the physics of these flows and the rapid advances in optical measurement techniques, like confocal scanning laser microscopy and high resolution stereo micro particle image velocimetry, are now making full field data retrieval possible. However, integration of microchannel devices in industrial processes will require on-line measurements for process control that do not necessarily rely on optical techniques. Developments are being made in the areas of non-intrusive sensors, magnetic resonance techniques, ultrasonic spectroscopy and on-line flow through measurement cells. The advances made in these areas will certainly be of increasing interest in the future as microchannels are more frequently employed in continuous flow equipment for industrial applications

    The effect of internal pipe wall roughness on the accuracy of clamp-on ultrasonic flow meters

    Get PDF
    Clamp-on transit-time ultrasonic flowmeters (UFMs) suffer from poor accuracy compared with spool-piece UFMs due to uncertainties that result from the in-field installation process. One of the important sources of uncertainties is internal pipe wall roughness which affects the flow profile and also causes significant scattering of ultrasound. This paper purely focuses on the parametric study to quantify the uncertainties (related to internal pipe wall roughness) induced by scattering of ultrasound and it shows that these effects are large even without taking into account the associated flow disturbances. The flowmeter signals for a reference clamp-on flowmeter setup were simulated using 2-D finite element analysis including simplifying assumptions (to simulate the effect of flow) that were deemed appropriate. The validity of the simulations was indirectly verified by carrying out experiments with different separation distances between ultrasonic probes. The error predicted by the simulations and the experimentally observed errors were in good agreement. Then, this simulation method was applied on pipe walls with rough internal surfaces. For ultrasonic waves at 1 MHz, it was found that compared with smooth pipes, pipes with only a moderately rough internal surface (with 0.2-mm rms and 5-mm correlation length) can exhibit systematic errors of 2 in the flow velocity measurement. This demonstrates that pipe internal surface roughness is a very important factor that limits the accuracy of clamp on UFMs

    Differential effects on membrane permeability and viability of human keratinocyte cells undergoing very low intensity megasonic fields

    Get PDF
    Among different therapeutic applications of Ultrasound (US), transient membrane sonoporation (SP) - a temporary, non-lethal porosity, mechanically induced in cell membranes through US exposure - represents a compelling opportunity towards an efficient and safe drug delivery. Nevertheless, progresses in this field have been limited by an insufficient understanding of the potential cytotoxic effects of US related to the failure of the cellular repair and to the possible activation of inflammatory pathway. In this framework we studied the in vitro effects of very low-intensity US on a human keratinocyte cell line, which represents an ideal model system of skin protective barrier cells which are the first to be involved during medical US treatments. Bioeffects linked to US application at 1 MHz varying the exposure parameters were investigated by fluorescence microscopy and fluorescence activated cell sorting. Our results indicate that keratinocytes undergoing low US doses can uptake drug model molecules with size and efficiency which depend on exposure parameters. According to sub-cavitation SP models, we have identified the range of doses triggering transient membrane SP, actually with negligible biological damage. By increasing US doses we observed a reduced cells viability and an inflammatory gene overexpression enlightening novel healthy relevant strategies
    • 

    corecore