933 research outputs found

    Development Of Carbon Based Neural Interface For Neural Stimulation/recording And Neurotransmitter Detection

    Get PDF
    Electrical stimulation and recording of neural cells have been widely used in basic neuroscience studies, neural prostheses, and clinical therapies. Stable neural interfaces that effectively communicate with the nervous system via electrodes are of great significance. Recently, flexible neural interfaces that combine carbon nanotubes (CNTs) and soft polymer substrates have generated tremendous interests. CNT based microelectrode arrays (MEAs) have shown enhanced electrochemical properties compared to commonly used electrode materials such as tungsten, platinum or titanium nitride. On the other hand, the soft polymer substrate can overcome the mechanical mismatch between the traditional rigid electrodes (or silicon shank) and the soft tissues for chronic use. However, most fabrication techniques suffer from low CNT yield, bad adhesion, and limited controllability. In addition, the electrodes were covered by randomly distributed CNTs in most cases. In this study, a novel fabrication method combining XeF2 etching and parylene deposition was presented to integrate the high quality vertical CNTs grown at high temperature with the heat sensitive parylene substrate in a highly controllable manner. Lower stimulation threshold voltage and higher signal to noise ratio have been demonstrated using vertical CNTs bundles compared to a Pt electrode and other randomly distributed CNT films. Adhesion has also been greatly improved. The work has also been extended to develop cuff shaped electrode for peripheral nerve stimulation. Fast scan cyclic voltammetry is an electrochemical detection technique suitable for in-vivo neurotransmitter detection because of the miniaturization, fast time response, good sensitivity and selectivity. Traditional single carbon fiber microelectrode has been limited to single detection for in-vivo application. Alternatively, pyrolyzed photoresist film (PPF) is a good candidate for this application as they are readily compatible with the microfabrication process for precise fabrication of microelectrode arrays. By the oxygen plasma treatment of photoresist prior to pyrolysis, we obtained carbon fiber arrays. Good sensitivity in dopamine detection by this carbon fiber arrays and improved adhesion have been demonstrated

    Advances in Nano Neuroscience: From Nanomaterials to Nanotools

    Get PDF
    During the last decades, neuroscientists have increasingly exploited a variety of artificial, de-novo synthesized materials with controlled nano-sized features. For instance, a renewed interest in the development of prostheses or neural interfaces was driven by the availability of novel nanomaterials that enabled the fabrication of implantable bioelectronics interfaces with reduced side effects and increased integration with the target biological tissue. The peculiar physical-chemical properties of nanomaterials have also contributed to the engineering of novel imaging devices toward sophisticated experimental settings, to smart fabricated scaffolds and microelectrodes, or other tools ultimately aimed at a better understanding of neural tissue functions. In this review, we focus on nanomaterials and specifically on carbon-based nanomaterials, such as carbon nanotubes (CNTs) and graphene. While these materials raise potential safety concerns, they represent a tremendous technological opportunity for the restoration of neuronal functions. We then describe nanotools such as nanowires and nano-modified MEA for high-performance electrophysiological recording and stimulation of neuronal electrical activity. We finally focus on the fabrication of three-dimensional synthetic nanostructures, used as substrates to interface biological cells and tissues in vitro and in vivo

    Organic electrode coatings for next-generation neural interfaces

    Get PDF
    Traditional neuronal interfaces utilize metallic electrodes which in recent years have reached a plateau in terms of the ability to provide safe stimulation at high resolution or rather with high densities of microelectrodes with improved spatial selectivity. To achieve higher resolution it has become clear that reducing the size of electrodes is required to enable higher electrode counts from the implant device. The limitations of interfacing electrodes including low charge injection limits, mechanical mismatch and foreign body response can be addressed through the use of organic electrode coatings which typically provide a softer, more roughened surface to enable both improved charge transfer and lower mechanical mismatch with neural tissue. Coating electrodes with conductive polymers or carbon nanotubes offers a substantial increase in charge transfer area compared to conventional platinum electrodes. These organic conductors provide safe electrical stimulation of tissue while avoiding undesirable chemical reactions and cell damage. However, the mechanical properties of conductive polymers are not ideal, as they are quite brittle. Hydrogel polymers present a versatile coating option for electrodes as they can be chemically modified to provide a soft and conductive scaffold. However, the in vivo chronic inflammatory response of these conductive hydrogels remains unknown. A more recent approach proposes tissue engineering the electrode interface through the use of encapsulated neurons within hydrogel coatings. This approach may provide a method for activating tissue at the cellular scale, however, several technological challenges must be addressed to demonstrate feasibility of this innovative idea. The review focuses on the various organic coatings which have been investigated to improve neural interface electrodes

    Carbon Nanotube Electrodes for Effective Interfacing with Retinal Tissue

    Get PDF
    We have investigated the use of carbon nanotube coated microelectrodes as an interface material for retinal recording and stimulation applications. Test devices were micro-fabricated and consisted of 60, 30 μm diameter electrodes at spacing of 200 μm. These electrodes were coated via chemical vapor deposition of carbon nanotubes, resulting in conducting, three dimensional surfaces with a high interfacial area. These attributes are important both for the quality of the cell-surface coupling as well as for electro-chemical interfacing efficiency. The entire chip was packaged to fit a commercial multielectrode recording and stimulation system. Electrical recordings of spontaneous spikes from whole-mount neonatal mouse retinas were consistently obtained minutes after retinas were placed over the electrodes, exhibiting typical bursting and propagating waves. Most importantly, the signals obtained with carbon nanotube electrodes have exceptionally high signal to noise ratio, reaching values as high as 75. Moreover, spikes are marked by a conspicuous gradual increase in amplitude recorded over a period of minutes to hours, suggesting improvement in cell-electrode coupling. This phenomenon is not observed in conventional commercial electrodes. Electrical stimulation using carbon nanotube electrodes was also achieved. We attribute the superior performances of the carbon nanotube electrodes to their three dimensional nature and the strong neuro-carbon nanotube affinity. The results presented here show the great potential of carbon nanotube electrodes for retinal interfacing applications. Specifically, our results demonstrate a route to achieve a reduction of the electrode down to few micrometers in order to achieve high efficacy local stimulation needed in retinal prosthetic devices

    Nanotechnology in peripheral nerve repair and reconstruction

    Get PDF
    The recent progress in biomaterials science and development of tubular conduits (TCs) still fails in solving the current challenges in the treatment of peripheral nerve injuries (PNIs), in particular when disease-related and long-gap defects need to be addressed. Nanotechnology-based therapies that seemed unreachable in the past are now being considered for the repair and reconstruction of PNIs, having the power to deliver bioactive molecules in a controlled manner, to tune cellular behavior, and ultimately guide tissue regeneration in an effective manner. It also offers opportunities in the imaging field, with a degree of precision never achieved before, which is useful for diagnosis, surgery and in the patientâ s follow-up. Nanotechnology approaches applied in PNI regeneration and theranostics, emphasizing the ones that are moving from the lab bench to the clinics, are herein overviewed.The authors acknowledge the Portuguese Foundation for Science and Technology (FCT) for the financial support provided to Joaquim M. Oliveira (IF/01285/2015) and Joana Silva-Correia (IF/00115/2015) under the program “Investigador FCT”.info:eu-repo/semantics/publishedVersio

    Electrochemical Detection of Neurotransmitters

    Get PDF
    Neurotransmitters are important chemical messengers in the nervous system that play a crucial role in physiological and physical health. Abnormal levels of neurotransmitters have been correlated with physical, psychotic, and neurodegenerative diseases such as Alzheimer\u27s, Parkinson\u27s, dementia, addiction, depression, and schizophrenia. Although multiple neurotechnological approaches have been reported in the literature, the detection and monitoring of neurotransmitters in the brain remains a challenge and continues to garner significant attention. Neurotechnology that provides high-throughput, as well as fast and specific quantification of target analytes in the brain, without negatively impacting the implanted region is highly desired for the monitoring of the complex intercommunication of neurotransmitters. Therefore, it is crucial to develop clinical assessment techniques that are sensitive and reliable to monitor and modulate these chemical messengers and screen diseases. This review focuses on summarizing the current electrochemical measurement techniques that are capable of sensing neurotransmitters with high temporal resolution in real time. Advanced neurotransmitter sensing platforms that integrate nanomaterials and biorecognition elements are explored

    Doctor of Philosophy

    Get PDF
    dissertationThe development of devices to electrically interact with the brain is a challenging task that could potentially restore motion to paralyzed patients and sight to those with profound blindness. Neural engineers have designed many types of microelectrode arrays (MEAs) with this challenge in mind. These MEAs can be implanted into brain tissue to both record neural signals and electrically stimulate neurons with high selectivity and spatial resolution. Implanted MEAs have allowed patients to control of a variety of prosthetic devices in clinical trials, but the longevity of such motor prostheses is limited to a few years. Performance decreases over time as MEAs lose the ability to record neuronal signals, preventing their widespread clinical use. Microstimulation via intracortical MEAs has also not achieved broad clinical implementation. While microstimulation for the restoration of vision is promising, human clinical trials are needed. Chronic in vivo functionality assays in model systems will provide key insight to facilitate such trials. There are three goals that may help address insufficient MEA longevity, as well as provide insight on microstimulation functionality. First, thorough characterizations of how performance decreases over time, both with and without stimulation, will be needed. Next, factors that affect the chronic performance of microstimulating MEAs must be further investigated. Finally, intervention strategies can be designed to mitigate these factors and improve long term MEA performance. This dissertation takes steps towards meeting these goals by means of three studies. First, the chronic performance of intracortically implanted recording and stimulating MEAs is examined. It is found that while performance of implanted MEAs in feline cortex is dynamic, catastrophic device failure does not occur with microstimulation. Next, a variety of factors that affect microstimulation studies are investigated. It is found that many factors, including device iv damage, anesthesia depth, the application of microstimulation, and the use of impedance as a reporter play a role in observations of performance variability. Finally, a promising intervention strategy, a carbon nanotube coating, is chronically tested in vivo, indicating that carbon nanotubes do not cause catastrophic device failure and may impart benefits to future generations of MEAs

    Biointegrated and wirelessly powered implantable brain devices: a review

    Get PDF
    Implantable neural interfacing devices have added significantly to neural engineering by introducing the low-frequency oscillations of small populations of neurons known as local field potential as well as high-frequency action potentials of individual neurons. Regardless of the astounding progression as of late, conventional neural modulating system is still incapable to achieve the desired chronic in vivo implantation. The real constraint emerges from mechanical and physical diffierences between implants and brain tissue that initiates an inflammatory reaction and glial scar formation that reduces the recording and stimulation quality. Furthermore, traditional strategies consisting of rigid and tethered neural devices cause substantial tissue damage and impede the natural behaviour of an animal, thus hindering chronic in vivo measurements. Therefore, enabling fully implantable neural devices, requires biocompatibility, wireless power/data capability, biointegration using thin and flexible electronics, and chronic recording properties. This paper reviews biocompatibility and design approaches for developing biointegrated and wirelessly powered implantable neural devices in animals aimed at long-term neural interfacing and outlines current challenges toward developing the next generation of implantable neural devices

    The impact of carbon based materials on hippocampal cells: from neurons to networks.

    Get PDF
    Tissue engineering and regenerative medicine require the constant development of synthetic materials to manufacture scaffolds thatbetter integrate into the target tissues (O\u2019Brien, 2011; Ku et al, 2013; Harrison et al, 2014). In this framework, newly synthesized nanomaterials made of pure carbon, in particular Carbon Nanotubes (Ijima, 1991) and Graphene (Novoselov et al, 2004) applications to biology received particular attention due to their outstanding physicochemical properties (Hirsch, 2010). Our team has performed pioneer works during the last decade, about the interactions of neural cells with carbon nanotubes (Lovat et al, 2005; Mazzatenta et al, 2007; Cellot et al, 2009; Cellot et al, 2011; Fabbro et al, 2012; Bosi et al, 2015), and with graphene (Fabbro et al, 2015; Rauti et al, 2016) or, more in general, with synthetic substrates (Cellot et al, 2016). The major aim of my work has been to use traditional and novel physiology tools to investigate further these \u201cneuro-hybrid systems\u201d, and to understand how far Carbon Nanotubes and Graphene can be pushed in neuroscience applications. With this aim, in the first part of my PhD I further elucidated the behavior of newly formed synapses in primary dissociated neurons when interfaced to bi-dimensional substrates of Multi-walled Carbon Nanotubes. I then addressed the homeostasis of invitro neural networks interfaced to pure graphene and I characterized for the first time the changes induced by this material in neurons. As last step, I set up a more complex biological in-vitro model, consisting of lesioned organotypic Entorhinal-Hippocampal cultures (Perederiy and Westbrook, 2013) and we described the regenerative features of Carbon Nanotubes in this lesion model. During my PhD I was also involved in two side projects: in the first one, in collaboration with Sebastian Reinhartz and Matthew Diamond (SISSA), we refine the possible approaches of the optogenetic technique, by manipulating neuronal responses with different light waveforms (Reinhartz et al, MS in preparation, in the appendix). In the second one, in collaboration with the group of Manus Biggs, from the National University of Galway, Ireland, we tested the biocompatibility and addressed the neural behavior of primary neural cells interfaced with Indium Tin Oxide (ITO) substrates with different roughness, thickness and conducting profiles (Vallejo-Giraldo et al, 2017)
    corecore