4,298 research outputs found

    Detecting and Mitigating Adversarial Attack

    Get PDF
    Automating arrhythmia detection from ECG requires a robust and trusted system that retains high accuracy under electrical disturbances. Deep neural networks have become a popular technique for tracing ECG signals, outperforming human experts. Many approaches have reached human-level performance in classifying arrhythmia from ECGs. Even convolutional neural networks are susceptible to adversarial examples as well that can also misclassify ECG signals. Moreover, they do not generalize well on the out-of-distribution dataset. Adversarial attacks are small crafted perturbations injected in the original data which manifest the out-of-distribution shifts in signal to misclassify the correct class. However, these architectures are vulnerable to adversarial attacks as well. The GAN architecture has been employed in recent works to synthesize adversarial ECG signals to increase existing training data. However, they use a disjointed CNN-based classification architecture to detect arrhythmia. Till now, no versatile architecture has been proposed that can detect adversarial examples and classify arrhythmia simultaneously. In this work, we propose two novel conditional generative adversarial networks (GAN), ECG-Adv-GAN and ECG-ATK-GAN, to simultaneously generate ECG signals for different categories and detect cardiac abnormalities. The model is conditioned on class-specific ECG signals to synthesize realistic adversarial examples. Moreover, the ECG-ATK-GAN is robust against adversarial attacked ECG signals and retains high accuracy when exposed to various types of adversarial attacks while classifying arrhythmia. We benchmark our architecture on six different white and black-box attacks and compare them with other recently proposed arrhythmia classification models. When considering the defense strategy, the variation of the adversarial attacks, both targeted and non-targeted, can determine the perturbation by calculating the gradient. Novel defenses are being introduced to improve upon existing techniques to fend off each new attack. This back-and-forth game between attack and defense is persistently recurring, and it became significant to understand the pattern and behavior of the attacker to create a robust defense. One widespread tactic is applying a mathematically based model like Game theory. To analyze this circumstance, we propose a computational framework of game theory to analyze the CNN Classifier's vulnerability, strategy, and outcomes by forming a simultaneous two-player game. We represent the interaction in the Stackelberg Game in Kuhn tree to study players' possible behaviors and actions by applying our Classifier's actual predicted values in CAPTCHA dataset. Thus, we interpret potential attacks in deep learning applications while representing viable defense strategies from the Game theoretical perspective

    A novel multivariate STeady-state index during general ANesthesia (STAN)

    Get PDF
    The assessment of the adequacy of general anesthesia for surgery, namely the nociception/anti-nociception balance, has received wide attention from the scientific community. Monitoring systems based on the frontal EEG/EMG, or autonomic state reactions (e.g. heart rate and blood pressure) have been developed aiming to objectively assess this balance. In this study a new multivariate indicator of patients' steady-state during anesthesia (STAN) is proposed, based on wavelet analysis of signals linked to noxious activation. A clinical protocol was designed to analyze precise noxious stimuli (laryngoscopy/intubation, tetanic, and incision), under three different analgesic doses; patients were randomized to receive either remifentanil 2.0, 3.0 or 4.0 ng/ml. ECG, PPG, BP, BIS, EMG and [Formula: see text] were continuously recorded. ECG, PPG and BP were processed to extract beat-to-beat information, and [Formula: see text] curve used to estimate the respiration rate. A combined steady-state index based on wavelet analysis of these variables, was applied and compared between the three study groups and stimuli (Wilcoxon signed ranks, Kruskal-Wallis and Mann-Whitney tests). Following institutional approval and signing the informed consent thirty four patients were enrolled in this study (3 excluded due to signal loss during data collection). The BIS index of the EEG, frontal EMG, heart rate, BP, and PPG wave amplitude changed in response to different noxious stimuli. Laryngoscopy/intubation was the stimulus with the more pronounced response [Formula: see text]. These variables were used in the construction of the combined index STAN; STAN responded adequately to noxious stimuli, with a more pronounced response to laryngoscopy/intubation (18.5-43.1 %, [Formula: see text]), and the attenuation provided by the analgesic, detecting steady-state periods in the different physiological signals analyzed (approximately 50 % of the total study time). A new multivariate approach for the assessment of the patient steady-state during general anesthesia was developed. The proposed wavelet based multivariate index responds adequately to different noxious stimuli, and attenuation provided by the analgesic in a dose-dependent manner for each stimulus analyzed in this study.The first author was supported by a scholarship from the Portuguese Foundation for Science and Technology (FCT SFRH/BD/35879/2007). The authors would also like to acknowledge the support of UISPA—System Integration and Process Automation Unit—Part of the LAETA (Associated Laboratory of Energy, Transports and Aeronautics) a I&D Unit of the Foundation for Science and Technology (FCT), Portugal. FCT support under project PEst-OE/EME/LA0022/2013.info:eu-repo/semantics/publishedVersio

    Focal Spot, Winter 2008/2009

    Get PDF
    https://digitalcommons.wustl.edu/focal_spot_archives/1110/thumbnail.jp

    BodyCloud: a SaaS approach for community body sensor networks

    Get PDF
    Body Sensor Networks (BSNs) have been recently introduced for the remote monitoring of human activities in a broad range of application domains, such as health care, emergency management, fitness and behaviour surveillance. BSNs can be deployed in a community of people and can generate large amounts of contextual data that require a scalable approach for storage, processing and analysis. Cloud computing can provide a flexible storage and processing infrastructure to perform both online and offline analysis of data streams generated in BSNs. This paper proposes BodyCloud, a SaaS approach for community BSNs that supports the development and deployment of Cloud-assisted BSN applications. BodyCloud is a multi-tier application-level architecture that integrates a Cloud computing platform and BSN data streams middleware. BodyCloud provides programming abstractions that allow the rapid development of community BSN applications. This work describes the general architecture of the proposed approach and presents a case study for the real-time monitoring and analysis of cardiac data streams of many individuals

    Aerospace Medicine and Biology: A continuing bibliography with indexes, supplement 145

    Get PDF
    This bibliography lists 301 reports, articles, and other documents introduced into the NASA scientific and technical information system in August 1975

    Aerospace medicine and biology: A continuing bibliography with indexes (supplement 349)

    Get PDF
    This bibliography lists 149 reports, articles and other documents introduced into the NASA Scientific and Technical Information System during April, 1991. Subject coverage includes: aerospace medicine and psychology, life support systems and controlled environments, safety equipment, exobiology and extraterrestrial life, and flight crew behavior and performance

    Sensor Developments for Electrophysiological Monitoring in Healthcare

    Get PDF
    Recent years have seen a renewal of interest in the development of sensor systems which can be used to monitor electrophysiological signals in a number of different settings. These include clinical, outside of the clinical setting with the subject ambulatory and going about their daily lives, and over long periods. The primary impetus for this is the challenge of providing healthcare for the ageing population based on home health monitoring, telehealth and telemedicine. Another stimulus is the demand for life sign monitoring of critical personnel such as fire fighters and military combatants. A related area of interest which, whilst not in the category of healthcare, utilises many of the same approaches, is that of sports physiology for both professional athletes and for recreation. Clinical diagnosis of conditions in, for example, cardiology and neurology remain based on conventional sensors, using established electrodes and well understood electrode placements. However, the demands of long term health monitoring, rehabilitation support and assistive technology for the disabled and elderly are leading research groups such as ours towards novel sensors, wearable and wireless enabled systems and flexible sensor arrays

    Development of a Real-Time Single-Lead Single-Beat Frequency-Independent Myocardial Infarction Detector

    Get PDF
    The central aim of this research is the development and deployment of a novel multilayer machine learning design with unique application for the diagnosis of myocardial infarctions (MIs) from individual heartbeats of single-lead electrocardiograms (EKGs) irrespective of their sampling frequencies over a given range. To the best of our knowledge, this design is the first to attempt inter-patient myocardial infarction detection from individual heartbeats of single-lead (lead II) electrocardiograms that achieves high accuracy and near real-time diagnosis. The processing time of 300 milliseconds to a diagnosis is just at the time range in between extremely fast heartbeats of around 300 milliseconds, or 200 beats per minute. The design achieves stable performance metrics over the frequency range of 202Hz to 2.8kHz with an accuracy of 77.12%, positive predictive value (PPV) of 75.85%, and a negative predictive value (NPV) of 83.02% over the entire PTB database; 85.07%, 81.54%, 87.31% over the PTB-XL (the largest EKG database available for research) validation set, and 84.17%, 78.37%, 87.55% over the PTB-XL test set. Major design contributions and findings of this work reveal (1) a method for the realtime detection of ventricular depolarization events in the PQRST complex from 12-lead electrocardiograms using Independent Component Analysis (ICA), with a slightly different use of ICA proposed for electrocardiogram analysis and R-peak detection/localization; (2) a multilayer Long-Short Term Memory (LSTM) neural network design that identifies infarcted patients from a single heartbeat of a single-lead (lead II) electrocardiogram; (3) and integrated LSTM neural network with an algorithm that detects the R-peaks in real time for instantaneous detection of myocardial infarctions and for effective monitoring of patients under cardiac stress and/or at risk of myocardial infarction; (4) a fully integrated 12-lead real-time classifier with even higher detection metrics and a deeper neural architecture, which could serve as a near real-time monitoring tool that could gauge disease progression and evaluate benefits gained from early intervention and treatment planning; (5) a real-time frequency-independent design based on a single-lead single-beat MI detector, which is of pivotal importance to deployment as there is no standard sampling frequency for EKGs, making them span a wider frequency spectrum. vi

    Evolutionary Optimization of Atrial Fibrillation Diagnostic Algorithms

    Get PDF
    The goal of this research is to introduce an improved method for detecting atrial fibrillation (AF). The foundation of our algorithm is the irregularity of the RR intervals in the electrocardiogram (ECG) signal, and their correlation with AF. Three statistical techniques, including root mean squares of successive differences (RMSSD), turning points ratio (TPR), and Shannon entropy (SE), are used to detect RR interval irregularity. We use the Massachusetts Institution of Technology / Beth Israel Hospital (MIT-BIH) atrial fibrillation databases and their annotations to tune the parameters of the statistical methods by biogeography-based optimization (BBO), which is an evolutionary optimization algorithm. We trained each statistical method to diagnose AF on each database. Then each trained method was tested on the rest of the databases. We were able to obtain accuracy levels as high as 99 for the detection of AF in the trained databases. We obtained accuracy levels of up to 75 in the tested database
    • …
    corecore