176 research outputs found

    Nonlinear system-identification of the filling phase of a wet-clutch system

    Get PDF
    The work presented illustrates how the choice of input perturbation signal and experimental design improves the derived model of a nonlinear system, in particular the dynamics of a wet-clutch system. The relationship between the applied input current signal and resulting output pressure in the filling phase of the clutch is established based on bandlimited periodic signals applied at different current operating points and signals approximating the desired filling current signal. A polynomial nonlinear state space model is estimated and validated over a range of measurements and yields better fits over a linear model, while the performance of either model depends on the perturbation signal used for model estimation

    Electrochemical impedance spectroscopy beyond linearity and stationarity - a critical review

    Get PDF
    Electrochemical impedance spectroscopy (EIS) is a widely used experimental technique for characterising materials and electrode reactions by observing their frequency-dependent impedance. Classical EIS measurements require the electrochemical process to behave as a linear time-invariant system. However, electrochemical processes do not naturally satisfy this assumption: the relation between voltage and current is inherently nonlinear and evolves over time. Examples include the corrosion of metal substrates and the cycling of Li-ion batteries. As such, classical EIS only offers models linearised at specific operating points. During the last decade, solutions were developed for estimating nonlinear and time-varying impedances, contributing to more general models. In this paper, we review the concept of impedance beyond linearity and stationarity, and detail different methods to estimate this from measured current and voltage data, with emphasis on frequency domain approaches using multisine excitation. In addition to a mathematical discussion, we measure and provide examples demonstrating impedance estimation for a Li-ion battery, beyond linearity and stationarity, both while resting and while charging

    A medical information system for monitoring respiratory function and related nonlinear dynamics

    Get PDF
    In this paper the nonlinear effects in the respiratory systems at low frequencies are measured and evaluated in healthy children and healthy adults. To this aim forced oscillations technique (FOT) has been used to non-invasively measure the lung tissue mechanics. FOT does not require any special effort from the patient in contrast with standardized tests where maneuvers are necessary. Hence, FOT is an ideal lung function test for extreme ages, more specifically children and elderly, given the simpleness of measurement technique. Hitherto, measurements at low frequencies (i.e. close to the breathing frequency similar to 0.3 Hz) have been invasively performed in sacrificed animals and on anesthetized humans. Here we measure in the frequency interval 0.1-2 Hz a total number of 94 volunteers (37 adults with ages between 25-35 years and 57 children with ages between 8-11 years). To evaluate the nonlinear contributions of the respiratory tissue, a novel T-index has been introduced. We have tested the hypothesis whether the nonlinear distortions are changing with growth/development of the respiratory tree and aim to quantify its dependence to biometric values. The results obtained indicate that the proposed index can differentiate between the two analyzed groups and that there is a dependence to age, height and weight. A medical information system may use this information to update predictions of respiratory function and provide aid in decision-making process of drug therapy

    Low frequency forced oscillation lung function test can distinguish dynamic tissue non-linearity in COPD patients

    Get PDF
    This paper introduces the use of low frequencies forced oscillation technique (FOT) in the presence of breathing signal. The hypothesis tested is to evaluate the sensitivity of FOT to various degrees of obstruction in COPD patients. The measurements were performed in the frequency range 0-2 Hz. The use of FOT to evaluate respiratory impedance has been broadly recognized and its complementary use next to standardized method as spirometry and body plethysmography has been well-documented. Typical use of FOT uses frequencies between 4-32 Hz and above. However, interesting information at frequencies below 4 Hz is related to viscoelastic properties of parenchyma. Structural changes in COPD affect viscoelastic properties and we propose to investigate the use of FOT at low frequencies with a fourth generation fan-based FOT device. The generator non-linearity introduced by the device is separated from the linear approximation of the impedance before evaluating the results on patients. Three groups of COPD obstruction, GOLD II, III, and IV are evaluated. We found significant differences in mechanical parameters (tissue damping, tissue elasticity, hysteresivity) and increased degrees of non-linear dynamic contributions in the impedance data with increasing degree of obstruction (p < 0.01). The results obtained suggest that the non-linear index correlates better with degrees of heterogeneity linked to COPD GOLD stages, than the currently used hysteresivity index. The protocol and method may prove useful to improve current diagnosis percentages for various COPD phenotypes
    • ā€¦
    corecore