590 research outputs found

    Estimating Carotid Pulse and Breathing Rate from Near-infrared Video of the Neck

    Full text link
    Objective: Non-contact physiological measurement is a growing research area that allows capturing vital signs such as heart rate (HR) and breathing rate (BR) comfortably and unobtrusively with remote devices. However, most of the approaches work only in bright environments in which subtle photoplethysmographic and ballistocardiographic signals can be easily analyzed and/or require expensive and custom hardware to perform the measurements. Approach: This work introduces a low-cost method to measure subtle motions associated with the carotid pulse and breathing movement from the neck using near-infrared (NIR) video imaging. A skin reflection model of the neck was established to provide a theoretical foundation for the method. In particular, the method relies on template matching for neck detection, Principal Component Analysis for feature extraction, and Hidden Markov Models for data smoothing. Main Results: We compared the estimated HR and BR measures with ones provided by an FDA-cleared device in a 12-participant laboratory study: the estimates achieved a mean absolute error of 0.36 beats per minute and 0.24 breaths per minute under both bright and dark lighting. Significance: This work advances the possibilities of non-contact physiological measurement in real-life conditions in which environmental illumination is limited and in which the face of the person is not readily available or needs to be protected. Due to the increasing availability of NIR imaging devices, the described methods are readily scalable.Comment: 21 pages, 15 figure

    Unconstrained video monitoring of breathing behavior and application to diagnosis of sleep apnea

    Get PDF
    This paper presents a new real-time automated infrared video monitoring technique for detection of breathing anomalies, and its application in the diagnosis of obstructive sleep apnea. We introduce a novel motion model to detect subtle, cyclical breathing signals from video, a new 3-D unsupervised self-adaptive breathing template to learn individuals' normal breathing patterns online, and a robust action classification method to recognize abnormal breathing activities and limb movements. This technique avoids imposing positional constraints on the patient, allowing patients to sleep on their back or side, with or without facing the camera, fully or partially occluded by the bed clothes. Moreover, shallow and abdominal breathing patterns do not adversely affect the performance of the method, and it is insensitive to environmental settings such as infrared lighting levels and camera view angles. The experimental results show that the technique achieves high accuracy (94% for the clinical data) in recognizing apnea episodes and body movements and is robust to various occlusion levels, body poses, body movements (i.e., minor head movement, limb movement, body rotation, and slight torso movement), and breathing behavior (e.g., shallow versus heavy breathing, mouth breathing, chest breathing, and abdominal breathing). © 2013 IEEE

    Wearable bioimpedance measurement for respiratory monitoring during inspiratory loading

    Get PDF
    Bioimpedance is an unobtrusive noninvasive technique to measure respiration and has a linear relation with volume during normal breathing. The objective of this paper was to assess this linear relation during inspiratory loading protocol and determine the best electrode configuration for bioimpedance measurement. The inspiratory load is a way to estimate inspiratory muscle function and has been widely used in studies of respiratory mechanics. Therefore, this protocol permitted us to evaluate bioimpedance performance under breathing pattern changes. We measured four electrode configurations of bioimpedance and airflow simultaneously in ten healthy subjects using a wearable device and a standard wired laboratory acquisition system, respectively. The subjects were asked to perform an incremental inspiratory threshold loading protocol during the measurements. The load values were selected to increase progressively until the 60% of the subject's maximal inspiratory pressure. The linear relation of the signals was assessed by Pearson correlation (r) and the waveform agreement by the mean absolute percentage error (MAPE), both computed cycle by cycle. The results showed a median greater than 0.965 in r coefficients and lower than 11 % in the MAPE values for the entire population in all loads and configurations. Thus, a strong linear relation was found during all loaded breathing and configurations. However, one out of the four electrode configurations showed robust results in terms of agreement with volume during the highest load. In conclusion, bioimpedance measurement using a wearable device is a noninvasive and a comfortable alternative to classical methods for monitoring respiratory diseases in normal and restrictive breathing.Postprint (published version

    Non-contact video-based assessment of the respiratory function using a RGB-D camera

    Get PDF
    A fully automatic, non-contact method for the assessment of the respiratory function is proposed using an RGB-D camera-based technology. The proposed algorithm relies on the depth channel of the camera to estimate the movements of the body’s trunk during breathing. It solves in fixed-time complexity, O(1), as the acquisition relies on the mean depth value of the target regions only using the color channels to automatically locate them. This simplicity allows the extraction of real-time values of the respiration, as well as the synchronous assessment on multiple body parts. Two different experiments have been performed: a first one conducted on 10 users in a single region and with a fixed breathing frequency, and a second one conducted on 20 users considering a simultaneous acquisition in two regions. The breath rate has then been computed and compared with a reference measurement. The results show a non-statistically significant bias of 0.11 breaths/min and 96% limits of agreement of -2.21/2.34 breaths/min regarding the breath-by-breath assessment. The overall real-time assessment shows a RMSE of 0.21 breaths/min. We have shown that this method is suitable for applications where respiration needs to be monitored in non-ambulatory and static environments.This research was funded by Ministerio de Ciencia e Innovación with grant number PID2020-116011.Postprint (published version

    Human Respiration Rate Measurement with High-Speed Digital Fringe Projection Technique

    Get PDF
    This paper proposes a non-contact continuous respiration monitoring method based on Fringe Projection Profilometry (FPP). This method aims to overcome the limitations of traditional intrusive techniques by providing continuous monitoring without interfering with normal breathing. The FPP sensor captures three-dimensional (3D) respiratory motion from the chest wall and abdomen, and the analysis algorithms extract respiratory parameters. The system achieved a high Signal-to-Noise Ratio (SNR) of 37 dB with an ideal sinusoidal respiration signal. Experimental results demonstrated that a mean correlation of 0.95 and a mean Root-Mean-Square Error (RMSE) of 0.11 breaths per minute (bpm) were achieved when comparing to a reference signal obtained from a spirometer

    Novel Methods for Weak Physiological Parameters Monitoring.

    Get PDF
    M.S. Thesis. University of Hawaiʻi at Mānoa 2017

    Breathing-Associated Facial Region Segmentation for Thermal Camera-Based Indirect Breathing Monitoring

    Get PDF
    (Objective)Breathing can be measured in a non-contact method using a thermal camera. The objective of this study investigates non-contact breathing measurements using thermal cameras, which have previously been limited to measuring the nostril only from the front where it is clearly visible. The previous method is challenging to use for other angles and frontal views, where the nostril is not well-represented. In this paper, we defined a new region called the breathing-associated-facial-region (BAFR) that reflects the physiological characteristics of breathing, and extract breathing signals from views of 45 and 90 degrees, including the frontal view where the nostril is not clearly visible. (Methods) Experiments were conducted on fifteen healthy subjects in different views, including frontal with and without nostril, 45-degree, and 90-degree views. A thermal camera (A655sc model, FLIR systems) was used for non-contact measurement, and biopac (MP150, Biopac-systems-Inc) was used as a chest breathing reference. (Results) The results showed that the proposed algorithm could extract stable breathing signals at various angles and views, achieving an average breathing cycle accuracy of 90.9% when applied compared to 65.6% without proposed algorithm. The average correlation value increases from 0.587 to 0.885. (Conclusion)The proposed algorithm can be monitored in a variety of environments and extract the BAFR at diverse angles and views. (Clinical Impact)The proposed algorithm shows the feasibility of non-contact breathing reliable monitoring that versatile and accurate than previous methods. The proposed algorithm could be used to monitor breathing in various clinical environments, including isolated wards, operation rooms, and intensive care units with high infection risks.ope

    Бесконтактный мониторинг дыхания с использованием оптических датчиков

    Get PDF
    Ціллю даної роботи є класифікація підходів до безконтактного моніторингу дихання і розробка структури системи моніторингу з усуненням артефактів міміки. Усі наявні методи були розділені на дві основні групи: методи на основі визначення дихання з 3-D зображення об'єкта і методи на основі 2-D обробки зображень. Була розроблена структура системи моніторингу дихання на основі оптичних сенсорів з можливістю видалення артефактів міміки. Новий підхід дозволяє покращити моніторинг дихання для об'єктів в положенні лежачи на спині і в позиції сидячи.The main goal of this paper is to develop classification of non-contact respiration monitoring approaches and proposal of structure for system with facial artifacts rejection. All available techniques were divided into two main groups: based on reconstruction of respiration from 3-D image of object and based on 2-D image processing of techniques. Structure of system for respiration monitoring using optical sensors with facial artifacts removing was developed. New approach allows improving of respiration monitoring for objects in supine position and in a sitting position.Целью работы является классификация подходов к бесконтактному мониторингу дыхания и разработка структуры системы мониторинга с устранением артефактов мимики. Все имеющиеся методы были разделены на две основные группы: методы на основе определения дыхания из 3-D изображения объекта и методы на основе 2-D обработки изображений. Была разработана структура системы мониторинга дыхания на основе оптических датчиков с возможностью удаления артефактов мимики. Новый подход позволяет улучшить мониторинг дыхания для объектов в положении лежа на спине и в позиции сидя
    corecore