    Stereotactic guidance for navigated percutaneous sacroiliac joint fusion.

    Get PDF
    Arthrodesis of the sacroiliac joint (SIJ) for surgical treatment of SIJ dysfunction has regained interest among spine specialists. Current techniques described in the literature most often utilize intraoperative fluoroscopy to aid in implant placement; however, image guidance for SIJ fusion may allow for minimally invasive percutaneous instrumentation with more precise implant placement. In the following cases, we performed percutaneous stereotactic navigated sacroiliac instrumentation using O-arm® multidimensional surgical imaging with StealthStation® navigation (Medtronic, Inc. Minneapolis, MN). Patients were positioned prone and an image-guidance reference frame was placed contralateral to the surgical site. O-arm® integrated with StealthStation® allowed immediate auto-registration. The skin incision was planned with an image-guidance probe. An image-guided awl, drill and tap were utilized to choose a starting point and trajectory. Threaded titanium cage(s) packed with autograft and/or allograft were then placed. O-arm® image-guidance allowed for implant placement in the SIJ with a small skin incision. However, we could not track the cage depth position with our current system, and in one patient, the SIJ cage had to be revised secondary to the anterior breach of sacrum

    Anatomically Constrained Video-CT Registration via the V-IMLOP Algorithm

    Full text link
    Functional endoscopic sinus surgery (FESS) is a surgical procedure used to treat acute cases of sinusitis and other sinus diseases. FESS is fast becoming the preferred choice of treatment due to its minimally invasive nature. However, due to the limited field of view of the endoscope, surgeons rely on navigation systems to guide them within the nasal cavity. State of the art navigation systems report registration accuracy of over 1mm, which is large compared to the size of the nasal airways. We present an anatomically constrained video-CT registration algorithm that incorporates multiple video features. Our algorithm is robust in the presence of outliers. We also test our algorithm on simulated and in-vivo data, and test its accuracy against degrading initializations.Comment: 8 pages, 4 figures, MICCA

    Towards an Implantable Vestibular Prosthesis: The Surgical Challenges

    Get PDF
    Published versio

    Review of robotic technology for keyhole transcranial stereotactic neurosurgery

    Get PDF
    The research of stereotactic apparatus to guide surgical devices began in 1908, yet a major part of today's stereotactic neurosurgeries still rely on stereotactic frames developed almost half a century ago. Robots excel at handling spatial information, and are, thus, obvious candidates in the guidance of instrumentation along precisely planned trajectories. In this review, we introduce the concept of stereotaxy and describe a standard stereotactic neurosurgery. Neurosurgeons' expectations and demands regarding the role of robots as assistive tools are also addressed. We list the most successful robotic systems developed specifically for or capable of executing stereotactic neurosurgery. A critical review is presented for each robotic system, emphasizing the differences between them and detailing positive features and drawbacks. An analysis of the listed robotic system features is also undertaken, in the context of robotic application in stereotactic neurosurgery. Finally, we discuss the current perspective, and future directions of a robotic technology in this field. All robotic systems follow a very similar and structured workflow despite the technical differences that set them apart. No system unequivocally stands out as an absolute best. The trend of technological progress is pointing toward the development of miniaturized cost-effective solutions with more intuitive interfaces.This work has been partially financed by the NETT Project (FP7-PEOPLE-2011-ITN-289146), ACTIVE Project (FP7-ICT-2009-6-270460), and FCT PhD grant (ref. SFRH/BD/86499/2012)

    Image-guided surgery and medical robotics in the cranial area

    Get PDF
    Surgery in the cranial area includes complex anatomic situations with high-risk structures and high demands for functional and aesthetic results. Conventional surgery requires that the surgeon transfers complex anatomic and surgical planning information, using spatial sense and experience. The surgical procedure depends entirely on the manual skills of the operator. The development of image-guided surgery provides new revolutionary opportunities by integrating presurgical 3D imaging and intraoperative manipulation. Augmented reality, mechatronic surgical tools, and medical robotics may continue to progress in surgical instrumentation, and ultimately, surgical care. The aim of this article is to review and discuss state-of-the-art surgical navigation and medical robotics, image-to-patient registration, aspects of accuracy, and clinical applications for surgery in the cranial area

    Advanced cranial navigation

    Get PDF
    Neurosurgery is performed with extremely low margins of error. Surgical inaccuracy may have disastrous consequences. The overall aim of this thesis was to improve accuracy in cranial neurosurgical procedures by the application of new technical aids. Two technical methods were evaluated: augmented reality (AR) for surgical navigation (Papers I-II) and the optical technique of diffuse reflectance spectroscopy (DRS) for real-time tissue identification (Papers III-V). Minimally invasive skull-base endoscopy has several potential benefits compared to traditional craniotomy, but approaching the skull base through this route implies that at-risk organs and surgical targets are covered by bone and out of the surgeon’s direct line of sight. In Paper I, a new application for AR-navigated endoscopic skull-base surgery, based on an augmented-reality surgical navigation (ARSN) system, was developed. The accuracy of the system, defined by mean target registration error (TRE), was evaluated and found to be 0.55±0.24 mm, the lowest value reported error in the literature. As a first step toward the development of a cranial application for AR navigation, in Paper II this ARSN system was used to enable insertions of biopsy needles and external ventricular drainages (EVDs). The technical accuracy (i.e., deviation from the target or intended path) and efficacy (i.e., insertion time) were assessed on a 3D-printed realistic, anthropomorphic skull and brain phantom; Thirty cranial biopsies and 10 EVD insertions were performed. Accuracy for biopsy was 0.8±0.43 mm with a median insertion time of 149 (87-233) seconds, and for EVD accuracy was 2.9±0.8 mm at the tip with a median angular deviation of 0.7±0.5° and a median insertion time of 188 (135-400) seconds. Glial tumors grow diffusely in the brain, and patient survival is correlated with the extent of tumor removal. Tumor borders are often invisible. Resection beyond borders as defined by conventional methods may further improve a patient’s prognosis. In Paper III, DRS was evaluated for discrimination between glioma and normal brain tissue ex vivo. DRS spectra and histology were acquired from 22 tumor samples and 9 brain tissue samples retrieved from 30 patients. Sensitivity and specificity for the detection of low-grade gliomas were 82.0% and 82.7%, respectively, with an AUC of 0.91. Acute ischemic stroke caused by large vessel occlusion is treated with endovascular thrombectomy, but treatment failure can occur when clot composition and thrombectomy technique are mismatched. Intra-procedural knowledge of clot composition could guide the choice of treatment modality. In Paper IV, DRS, in vivo, was evaluated for intravascular clot characterization. Three types of clot analogs, red blood cell (RBC)-rich, fibrin-rich and mixed clots, were injected into the external carotids of a domestic pig. An intravascular DRS probe was used for in-situ measurements of clots, blood, and vessel walls, and the spectral data were analyzed. DRS could differentiate clot types, vessel walls, and blood in vivo (p<0,001). The sensitivity and specificity for detection were 73.8% and 98.8% for RBC clots, 100% and 100% for mixed clots, and 80.6% and 97.8% for fibrin clots, respectively. Paper V evaluated DRS for characterization of human clot composition ex vivo: 45 clot units were retrieved from 29 stroke patients and examined with DRS and histopathological evaluation. DRS parameters correlated with clot RBC fraction (R=81, p<0.001) and could be used for the classification of clot type with sensitivity and specificity rates for the detection of RBC-rich clots of 0.722 and 0.846, respectively. Applied in an intravascular probe, DRS may provide intra-procedural information on clot composition to improve endovascular thrombectomy efficiency