4,678 research outputs found

    Doppler radar-based non-contact health monitoring for obstructive sleep apnea diagnosis: A comprehensive review

    Get PDF
    Today’s rapid growth of elderly populations and aging problems coupled with the prevalence of obstructive sleep apnea (OSA) and other health related issues have affected many aspects of society. This has led to high demands for a more robust healthcare monitoring, diagnosing and treatments facilities. In particular to Sleep Medicine, sleep has a key role to play in both physical and mental health. The quality and duration of sleep have a direct and significant impact on people’s learning, memory, metabolism, weight, safety, mood, cardio-vascular health, diseases, and immune system function. The gold-standard for OSA diagnosis is the overnight sleep monitoring system using polysomnography (PSG). However, despite the quality and reliability of the PSG system, it is not well suited for long-term continuous usage due to limited mobility as well as causing possible irritation, distress, and discomfort to patients during the monitoring process. These limitations have led to stronger demands for non-contact sleep monitoring systems. The aim of this paper is to provide a comprehensive review of the current state of non-contact Doppler radar sleep monitoring technology and provide an outline of current challenges and make recommendations on future research directions to practically realize and commercialize the technology for everyday usage

    Novel Methods for Weak Physiological Parameters Monitoring.

    Get PDF
    M.S. Thesis. University of Hawaiʻi at Mānoa 2017

    Physiological Parameter Sensing with Wearable Devices and Non-Contact Dopper Radar.

    Get PDF
    M.S. Thesis. University of Hawaiʻi at Mānoa 2017

    A simple and cost-effective method for cable root detection and extension measurement in estuary wetland forests

    Get PDF
    This work presents the development of a low-cost method to measure the length cable roots of black mangrove (Avicennia germinans) trees to define the boundaries of central part of the anchoring root system (CPRS) without the need to fully expose root systems. The method was tested to locate and measure the length shallow woody root systems. An ultrasonic Doppler fetal monitor (UD) and a stock of steel rods (SR) were used to probe root locations without removing sediments from the surface, measure their length and estimate root-soil plate dimensions. The method was validated by comparing measurements with root lengths taken through direct measurement of excavated cable roots and from root-soil plate radii (exposed root-soil material when a tree tips over) of five up-rooted trees with stem diameters (D130) ranging between 10 and 50 cm. The mean CPRS radius estimated with the use of the Doppler was directly correlated with tree stem diameter and was not significantly different from the root-soil plate mean radius measured from up-rooted trees or from CPRS approximated by digging trenches. Our method proved to be effective and reliable in following cable roots for large amounts of trees of both black and white mangrove trees. In a period of 40 days of work, three people were capable of measuring 648 roots belonging to 81 trees, out of which 37% were found grafted to other tree roots. This simple method can be helpful in following shallow root systems with minimal impact and help map root connection networks of grafted trees

    Doppler Radar Vital Signs Detection Method Based on Higher Order Cyclostationary

    Get PDF
    Due to the non-contact nature, using Doppler radar sensors to detect vital signs such as heart and respiration rates of a human subject is getting more and more attention. However, the related detection-method research meets lots of challenges due to electromagnetic interferences, clutter and random motion interferences. In this paper, a novel third-order cyclic cummulant (TOCC) detection method, which is insensitive to Gaussian interference and non-cyclic signals, is proposed to investigate the heart and respiration rate based on continuous wave Doppler radars. The k-th order cyclostationary properties of the radar signal with hidden periodicities and random motions are analyzed. The third-order cyclostationary detection theory of the heart and respiration rate is studied. Experimental results show that the third-order cyclostationary approach has better estimation accuracy for detecting the vital signs from the received radar signal under low SNR, strong clutter noise and random motion interferences

    Noncontact monitoring of heartbeat and movements during sleep using a pair of millimeter-wave ultra-wideband radar systems

    Get PDF
    We experimentally evaluate the performance of a noncontact system that measures the heartbeat of a sleeping person. The proposed system comprises a pair of radar systems installed at two different positions. We use millimeter-wave ultra-wideband multiple-input multiple-output array radar systems and evaluate the performance attained in measuring the heart inter-beat interval and body movement. The importance of using two radar systems instead of one is demonstrated in this paper. We conduct three types of experiments; the first and second experiments are radar measurements of three participants lying on a bed with and without body movement, while the third experiment is the radar measurement of a participant actually sleeping overnight. The experiments demonstrate that the performance of the radar-based vital measurement strongly depends on the orientation of the person under test. They also show that the proposed system detects 70% of rolling-over movements made overnight

    Doppler Radar Techniques for Distinct Respiratory Pattern Recognition and Subject Identification.

    Get PDF
    Ph.D. Thesis. University of Hawaiʻi at Mānoa 2017
    corecore