39,199 research outputs found
Estimating Carotid Pulse and Breathing Rate from Near-infrared Video of the Neck
Objective: Non-contact physiological measurement is a growing research area
that allows capturing vital signs such as heart rate (HR) and breathing rate
(BR) comfortably and unobtrusively with remote devices. However, most of the
approaches work only in bright environments in which subtle
photoplethysmographic and ballistocardiographic signals can be easily analyzed
and/or require expensive and custom hardware to perform the measurements.
Approach: This work introduces a low-cost method to measure subtle motions
associated with the carotid pulse and breathing movement from the neck using
near-infrared (NIR) video imaging. A skin reflection model of the neck was
established to provide a theoretical foundation for the method. In particular,
the method relies on template matching for neck detection, Principal Component
Analysis for feature extraction, and Hidden Markov Models for data smoothing.
Main Results: We compared the estimated HR and BR measures with ones provided
by an FDA-cleared device in a 12-participant laboratory study: the estimates
achieved a mean absolute error of 0.36 beats per minute and 0.24 breaths per
minute under both bright and dark lighting.
Significance: This work advances the possibilities of non-contact
physiological measurement in real-life conditions in which environmental
illumination is limited and in which the face of the person is not readily
available or needs to be protected. Due to the increasing availability of NIR
imaging devices, the described methods are readily scalable.Comment: 21 pages, 15 figure
A Comparative Evaluation of Heart Rate Estimation Methods using Face Videos
This paper presents a comparative evaluation of methods for remote heart rate
estimation using face videos, i.e., given a video sequence of the face as
input, methods to process it to obtain a robust estimation of the subjects
heart rate at each moment. Four alternatives from the literature are tested,
three based in hand crafted approaches and one based on deep learning. The
methods are compared using RGB videos from the COHFACE database. Experiments
show that the learning-based method achieves much better accuracy than the hand
crafted ones. The low error rate achieved by the learning based model makes
possible its application in real scenarios, e.g. in medical or sports
environments.Comment: Accepted in "IEEE International Workshop on Medical Computing
(MediComp) 2020
DistancePPG: Robust non-contact vital signs monitoring using a camera
Vital signs such as pulse rate and breathing rate are currently measured
using contact probes. But, non-contact methods for measuring vital signs are
desirable both in hospital settings (e.g. in NICU) and for ubiquitous in-situ
health tracking (e.g. on mobile phone and computers with webcams). Recently,
camera-based non-contact vital sign monitoring have been shown to be feasible.
However, camera-based vital sign monitoring is challenging for people with
darker skin tone, under low lighting conditions, and/or during movement of an
individual in front of the camera. In this paper, we propose distancePPG, a new
camera-based vital sign estimation algorithm which addresses these challenges.
DistancePPG proposes a new method of combining skin-color change signals from
different tracked regions of the face using a weighted average, where the
weights depend on the blood perfusion and incident light intensity in the
region, to improve the signal-to-noise ratio (SNR) of camera-based estimate.
One of our key contributions is a new automatic method for determining the
weights based only on the video recording of the subject. The gains in SNR of
camera-based PPG estimated using distancePPG translate into reduction of the
error in vital sign estimation, and thus expand the scope of camera-based vital
sign monitoring to potentially challenging scenarios. Further, a dataset will
be released, comprising of synchronized video recordings of face and pulse
oximeter based ground truth recordings from the earlobe for people with
different skin tones, under different lighting conditions and for various
motion scenarios.Comment: 24 pages, 11 figure
Silhouette-based gait recognition using Procrustes shape analysis and elliptic Fourier descriptors
This paper presents a gait recognition method which combines spatio-temporal motion characteristics, statistical and physical parameters (referred to as STM-SPP) of a human subject for its classification by analysing shape of the subject's silhouette contours using Procrustes shape analysis (PSA) and elliptic Fourier descriptors (EFDs). STM-SPP uses spatio-temporal gait characteristics and physical parameters of human body to resolve similar dissimilarity scores between probe and gallery sequences obtained by PSA. A part-based shape analysis using EFDs is also introduced to achieve robustness against carrying conditions. The classification results by PSA and EFDs are combined, resolving tie in ranking using contour matching based on Hu moments. Experimental results show STM-SPP outperforms several silhouette-based gait recognition methods
- …