15,066 research outputs found
Software Defined Networks based Smart Grid Communication: A Comprehensive Survey
The current power grid is no longer a feasible solution due to
ever-increasing user demand of electricity, old infrastructure, and reliability
issues and thus require transformation to a better grid a.k.a., smart grid
(SG). The key features that distinguish SG from the conventional electrical
power grid are its capability to perform two-way communication, demand side
management, and real time pricing. Despite all these advantages that SG will
bring, there are certain issues which are specific to SG communication system.
For instance, network management of current SG systems is complex, time
consuming, and done manually. Moreover, SG communication (SGC) system is built
on different vendor specific devices and protocols. Therefore, the current SG
systems are not protocol independent, thus leading to interoperability issue.
Software defined network (SDN) has been proposed to monitor and manage the
communication networks globally. This article serves as a comprehensive survey
on SDN-based SGC. In this article, we first discuss taxonomy of advantages of
SDNbased SGC.We then discuss SDN-based SGC architectures, along with case
studies. Our article provides an in-depth discussion on routing schemes for
SDN-based SGC. We also provide detailed survey of security and privacy schemes
applied to SDN-based SGC. We furthermore present challenges, open issues, and
future research directions related to SDN-based SGC.Comment: Accepte
Robust energy disaggregation using appliance-specific temporal contextual information
An extension of the baseline non-intrusive load monitoring approach for energy disaggregation using temporal contextual information is presented in this paper. In detail, the proposed approach uses a two-stage disaggregation methodology with appliance-specific temporal contextual information in order to capture time-varying power consumption patterns in low-frequency datasets. The proposed methodology was evaluated using datasets of different sampling frequency, number and type of appliances. When employing appliance-specific temporal contextual information, an improvement of 1.5% up to 7.3% was observed. With the two-stage disaggregation architecture and using appliance-specific temporal contextual information, the overall energy disaggregation accuracy was further improved across all evaluated datasets with the maximum observed improvement, in terms of absolute increase of accuracy, being equal to 6.8%, thus resulting in a maximum total energy disaggregation accuracy improvement equal to 10.0%.Peer reviewedFinal Published versio
- …