67 research outputs found

    Review of Artifact Rejection Methods for Electroencephalographic Systems

    Get PDF
    Technologies using electroencephalographic (EEG) signals have been penetrated into public by the development of EEG systems. During EEG system operation, recordings ought to be obtained under no restriction of movement for routine use in the real world. However, the lack of consideration of situational behavior constraints will cause technical/biological artifacts that often mixed with EEG signals and make the signal processing difficult in all respects by ingeniously disguising themselves as EEG components. EEG systems integrating gold standard or specialized device in their processing strategies would appear as daily tools in the future if they are unperturbed to such obstructions. In this chapter, we describe algorithms for artifact rejection in multi-/single-channel. In particular, some existing single-channel artifact rejection methods that will exhibit beneficial information to improve their performance in online EEG systems were summarized by focusing on the advantages and disadvantages of algorithms

    Automatic Artifact Removal from Electroencephalogram Data Based on A Priori Artifact Information

    Get PDF

    Ocular Artifact Detection and Removing from EEG by wavelet families: A Comparative Study

    Get PDF
    The Electroencephalogram (EEG) is a biological signal that represents the electrical activity of the brain. Biological artifacts like ocular artifact (OA) are one of the main interferences in EEG recordings. Eye blinks and movements of the eyeballs produce a signal known as electrooculogram (EOG) that these are 10 to 100 times stronger than the EEG signal. Due to the frequency range of EEG signal and OA which has overlapping with each other, identify and removing of the EOG artifacts are one of the main challenges for researchers, because an incorrect denoising may lose some of the important information of EEG signals. In this context, our aim is to propose a technique based on wavelet transform for accurate identification of the blink artifact zone and removal of EEG signals. We propose using absolute value of signal reconstructed details for blink zone detection and the efficiency of wavelet families to remove the blink artifact which is evaluated by calculating the mean squared error (MSE) between denoised and clean EEG signals and comparing with the results before and after artifact removing show that db7, sym7, coif5, rbio1.5 and dmey at 4th level are preferable and effective in blink artifact zone detection and db7, coif5, dmey, db5 and db9 respectively provide the best result for blink artifact removing with minimum loss important information. Keywords: EEG, EOG, OA, Wavelet transform, MS

    Improving the performance of translation wavelet transform using BMICA

    Get PDF
    Research has shown Wavelet Transform to be one of the best methods for denoising biosignals. Translation-Invariant form of this method has been found to be the best performance. In this paper however we utilize this method and merger with our newly created Independent Component Analysis method – BMICA. Different EEG signals are used to verify the method within the MATLAB environment. Results are then compared with those of the actual Translation-Invariant algorithm and evaluated using the performance measures Mean Square Error (MSE), Peak Signal to Noise Ratio (PSNR), Signal to Distortion Ratio (SDR), and Signal to Interference Ratio (SIR). Experiments revealed that the BMICA Translation-Invariant Wavelet Transform out performed in all four measures. This indicates that it performed superior to the basic Translation- Invariant Wavelet Transform algorithm producing cleaner EEG signals which can influence diagnosis as well as clinical studies of the brain

    EEG Artifact Removal Using a Wavelet Neural Network

    Get PDF
    !n this paper we developed a wavelet neural network. (WNN) algorithm for Electroencephalogram (EEG) artifact removal without electrooculographic (EOG) recordings. The algorithm combines the universal approximation characteristics of neural network and the time/frequency property of wavelet. We. compared the WNN algorithm with .the ICA technique ,and a wavelet thresholding method, which was realized by using the Stein's unbiased risk estimate (SURE) with an adaptive gradient-based optimal threshold. Experimental results on a driving test data set show that WNN can remove EEG artifacts effectively without diminishing useful EEG information even for very noisy data

    Wavelet-Based Artifact Identification and Separation Technique for EEG Signals during Galvanic Vestibular Stimulation

    Get PDF
    We present a new method for removing artifacts in electroencephalography (EEG) records during Galvanic Vestibular Stimulation (GVS). The main challenge in exploiting GVS is to understand how the stimulus acts as an input to brain. We used EEG to monitor the brain and elicit the GVS reflexes. However, GVS current distribution throughout the scalp generates an artifact on EEG signals. We need to eliminate this artifact to be able to analyze the EEG signals during GVS. We propose a novel method to estimate the contribution of the GVS current in the EEG signals at each electrode by combining time-series regression methods with wavelet decomposition methods. We use wavelet transform to project the recorded EEG signal into various frequency bands and then estimate the GVS current distribution in each frequency band. The proposed method was optimized using simulated signals, and its performance was compared to well-accepted artifact removal methods such as ICA-based methods and adaptive filters. The results show that the proposed method has better performance in removing GVS artifacts, compared to the others. Using the proposed method, a higher signal to artifact ratio of −1.625 dB was achieved, which outperformed other methods such as ICA-based methods, regression methods, and adaptive filters

    Selection of Mother Wavelet Function for Multi-Channel EEG Signals Analysis during a Working Memory Task

    Get PDF
    We performed a comparative study to select the efficient mother wavelet (MWT) basis functions that optimally represent the signal characteristics of the electrical activity of the human brain during a working memory (WM) task recorded through electro-encephalography (EEG). Nineteen EEG electrodes were placed on the scalp following the 10–20 system. These electrodes were then grouped into five recording regions corresponding to the scalp area of the cerebral cortex. Sixty-second WM task data were recorded from ten control subjects. Forty-five MWT basis functions from orthogonal families were investigated. These functions included Daubechies (db1–db20), Symlets (sym1–sym20), and Coiflets (coif1–coif5). Using ANOVA, we determined the MWT basis functions with the most significant differences in the ability of the five scalp regions to maximize their cross-correlation with the EEG signals. The best results were obtained using “sym9” across the five scalp regions. Therefore, the most compatible MWT with the EEG signals should be selected to achieve wavelet denoising, decomposition, reconstruction, and sub-band feature extraction. This study provides a reference of the selection of efficient MWT basis functions

    Automatic Artifact Removal in EEG of Normal and Demented Individuals Using ICA–WT during Working Memory Tasks

    Get PDF
    Characterizing dementia is a global challenge in supporting personalized health care. The electroencephalogram (EEG) is a promising tool to support the diagnosis and evaluation of abnormalities in the human brain. The EEG sensors record the brain activity directly with excellent time resolution. In this study, EEG sensor with 19 electrodes were used to test the background activities of the brains of five vascular dementia (VaD), 15 stroke-related patients with mild cognitive impairment (MCI), and 15 healthy subjects during a working memory (WM) task. The objective of this study is twofold. First, it aims to enhance the recorded EEG signals using a novel technique that combines automatic independent component analysis (AICA) and wavelet transform (WT), that is, the AICA–WT technique; second, it aims to extract and investigate the spectral features that characterize the post-stroke dementia patients compared to the control subjects. The proposed AICA–WT technique is a four-stage approach. In the first stage, the independent components (ICs) were estimated. In the second stage, three-step artifact identification metrics were applied to detect the artifactual components. The components identified as artifacts were marked as critical and denoised through DWT in the third stage. In the fourth stage, the corrected ICs were reconstructed to obtain artifact-free EEG signals. The performance of the proposed AICA–WT technique was compared with those of two other techniques based on AICA and WT denoising methods using cross-correlation X C o r r and peak signal to noise ratio ( P S N R ) (ANOVA, p ˂ 0.05). The AICA–WT technique exhibited the best artifact removal performance. The assumption that there would be a deceleration of EEG dominant frequencies in VaD and MCI patients compared with control subjects was assessed with AICA–WT (ANOVA, p ˂ 0.05). Therefore, this study may provide information on post-stroke dementia particularly VaD and stroke-related MCI patients through spectral analysis of EEG background activities that can help to provide useful diagnostic indexes by using EEG signal processing
    corecore