2,258 research outputs found

    Advanced robust tracking control of a powered wheelchair system.

    Full text link
    In this paper, the dynamic multivariable model of the wheelchair system is obtained including the presence of transportation lags. The triangular diagonal dominance (TDD) decoupling technique is applied to reduce this multivariable control problem into two independent scalar control problems. An advanced robust control technique for the wheelchair has been developed based on the combination of a TDD decoupling strategy and neural network controller design. The results obtained from the real-time implementation confirm that robust performance for this multivariable wheelchair control system can indeed be achieved

    Implementation Of Internal Model Control (IMC) In Continuous Distillation Column.

    Get PDF
    Distillation columns have been widely used in chemical plants for separation process. The high nonlinearity and dynamic behavior of the column make them hard to control

    A Survey of Decentralized Adaptive Control

    Get PDF

    Data-driven fault diagnosis of awind farm benchmark model

    Get PDF
    The fault diagnosis of wind farms has been proven to be a challenging task, and motivates the research activities carried out through this work. Therefore, this paper deals with the fault diagnosis of a wind park benchmark model, and it considers viable solutions to the problem of earlier fault detection and isolation. The design of the fault indicator involves data-driven approaches, as they can represent effective tools for coping with poor analytical knowledge of the system dynamics, noise, uncertainty, and disturbances. In particular, the proposed data-driven solutions rely on fuzzy models and neural networks that are used to describe the strongly nonlinear relationships between measurement and faults. The chosen architectures rely on nonlinear autoregressive with exogenous input models, as they can represent the dynamic evolution of the system over time. The developed fault diagnosis schemes are tested by means of a high-fidelity benchmark model that simulates the normal and the faulty behaviour of a wind farm installation. The achieved performances are also compared with those of a model-based approach relying on nonlinear differential geometry tools. Finally, a Monte-Carlo analysis validates the robustness and reliability of the proposed solutions against typical parameter uncertainties and disturbances.The fault diagnosis of wind farms has been proven to be a challenging task, and motivates the research activities carried out through this work. Therefore, this paper deals with the fault diagnosis of a wind park benchmark model, and it considers viable solutions to the problem of earlier fault detection and isolation. The design of the fault indicator involves data-driven approaches, as they can represent effective tools for coping with poor analytical knowledge of the system dynamics, noise, uncertainty, and disturbances. In particular, the proposed data-driven solutions rely on fuzzy models and neural networks that are used to describe the strongly nonlinear relationships between measurement and faults. The chosen architectures rely on nonlinear autoregressive with exogenous input models, as they can represent the dynamic evolution of the system over time. The developed fault diagnosis schemes are tested by means of a high-fidelity benchmark model that simulates the normal and the faulty behaviour of a wind farm installation. The achieved performances are also compared with those of a model-based approach relying on nonlinear differential geometry tools. Finally, a Monte-Carlo analysis validates the robustness and reliability of the proposed solutions against typical parameter uncertainties and disturbances
    corecore