4,834 research outputs found

    Electrical vestibular stimulation in humans. A narrative review

    Get PDF
    Background: In patients with bilateral vestibulopathy, the regular treatment options, such as medication, surgery, and/ or vestibular rehabilitation, do not always suffice. Therefore, the focus in this field of vestibular research shifted to electri- cal vestibular stimulation (EVS) and the development of a system capable of artificially restoring the vestibular func- tion. Key Message: Currently, three approaches are being investigated: vestibular co-stimulation with a cochlear im- plant (CI), EVS with a vestibular implant (VI), and galvanic vestibular stimulation (GVS). All three applications show promising results but due to conceptual differences and the experimental state, a consensus on which application is the most ideal for which type of patient is still missing. Summa- ry: Vestibular co-stimulation with a CI is based on “spread of excitation,” which is a phenomenon that occurs when the currents from the CI spread to the surrounding structures and stimulate them. It has been shown that CI activation can indeed result in stimulation of the vestibular structures. Therefore, the question was raised whether vestibular co- stimulation can be functionally used in patients with bilat- eral vestibulopathy. A more direct vestibular stimulation method can be accomplished by implantation and activa- tion of a VI. The concept of the VI is based on the technology and principles of the CI. Different VI prototypes are currently being evaluated regarding feasibility and functionality. So far, all of them were capable of activating different types of vestibular reflexes. A third stimulation method is GVS, which requires the use of surface electrodes instead of an implant- ed electrode array. However, as the currents are sent through the skull from one mastoid to the other, GVS is rather unspe- cific. It should be mentioned though, that the reported spread of excitation in both CI and VI use also seems to in- duce a more unspecific stimulation. Although all three ap- plications of EVS were shown to be effective, it has yet to be defined which option is more desirable based on applicabil- ity and efficiency. It is possible and even likely that there is a place for all three approaches, given the diversity of the pa- tient population who serves to gain from such technologies

    Sensors for biomedical applications

    Get PDF
    This paper considers the impact during the last decade of modern IC technology, microelectronics, thin- and thick-film technology, fibre optic technology, etc. on the development of sensors for biomedical applications

    Neuromodulation: present and emerging methods.

    Get PDF
    Neuromodulation has wide ranging potential applications in replacing impaired neural function (prosthetics), as a novel form of medical treatment (therapy), and as a tool for investigating neurons and neural function (research). Voltage and current controlled electrical neural stimulation (ENS) are methods that have already been widely applied in both neuroscience and clinical practice for neuroprosthetics. However, there are numerous alternative methods of stimulating or inhibiting neurons. This paper reviews the state-of-the-art in ENS as well as alternative neuromodulation techniques-presenting the operational concepts, technical implementation and limitations-in order to inform system design choices

    Electromagnetic Modeling of Pacemaker Lead Heating During MRI

    Get PDF
    <p>The electromagnetic part of pacemaker lead heating during magnetic resonance imaging (MRI) is a resonant phenomenon which is complicated by, among other factors, the wide range of length scales involved in the problem. In this work, the multi-scale part of the problem is taken into special consideration during the modeling process. The model incorporates a radio frequency coil, a human body phantom, and a highly detailed model of a pacemaker system with a bipolar lead.</p> <p>Several configurations of pacemaker systems exposed to MRI are modeled and the results clearly show the importance of detailed lead modeling. Furthermore, modeling of resonant structures is investigated by a comparison between different modeling techniques.</p

    Design and implementation of compact dual-band conformal antenna for leadless cardiac pacemaker system

    Get PDF
    The leadless cardiac pacemaker is a pioneering device for heart patients. Its rising success requires the design of compact implantable antennas. In this paper, we describe a circularly polarized Hilbert curve inspired loop antenna. The proposed antenna works in the WMTS (Wireless Medical Telemetry Services) 1.4 GHz and ISM (Industrial, Scientific, and Medical) 2.45 GHz bands. High dielectric constant material Rogers RT/Duroid 6010 LM ([Formula: see text]=10) and fractal geometry helps to design the antenna with a small footprint of 9.1 mm3 (6 mm × 6 mm × 0.254 mm). The designed antenna has a conformal shape that fits inside a leadless pacemaker's capsule is surrounded by IC models and battery, which are tightly packed in the device enclosure. Subsequently, the integrated prototype is simulated deep inside at the center of the multi-layer canonical heart model. To verify experimentally, we have put dummy electronics (IC and battery) inside the 3D printed pacemaker's capsule and surfaced the fabricated conformal antenna around the inner curved body of the TCP (Transcatheter Pacing) capsule. Furthermore, we have tested the TCP capsule by inserting it in a ballistic gel phantom and minced pork. The measured impedance bandwidths at 1.4 GHz and 2.45 GHz are 250 MHz and 430 MHz, whereas measured gains are - 33.2 dBi, and - 28.5 dBi, respectively

    Multi-Electrode Pacemaker

    Get PDF
    O principal objetivo desta dissertação é apresentar uma pesquisa de mercado sobre as tecnologias existentes bem como descrever um método abrangente para alcançar o protótipo de um pacemaker implantável com recursos sem fio.The main objective of this dissertation is to present a market survey on existing technologies as well as to depict a comprehensive method to achieve the prototype of an implantable pacemaker with wireless capabilities

    A foot drop compensation device based on surface multi-field functional electrical stimulation—Usability study in a clinical environment

    Get PDF
    Functional electrical stimulation applies electrical pulses to the peripheral nerves to artificially achieve a sensory/motor function. When applied for the compensation of foot drop it provides both assistive and therapeutic effects. Multi-field electrodes have shown great potential but may increase the complexity of these systems. Usability aspects should be checked to ensure their success in clinical environments. We developed the Fesia Walk device, based on a surface multi-field electrode and an automatic calibration algorithm, and carried out a usability study to check the feasibility of integrating this device in therapeutic programs in clinical environments. The study included 4 therapists and 10 acquired brain injury subjects (8 stroke and 2 traumatic brain injury).The author(s) disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: Part of this study was supported by the European Regional Development Funds through the Interreg Sudoe Program, project SOE1/P1/F0370
    corecore