3,428 research outputs found
A Hierachical Evolutionary Algorithm for Multiobjective Optimization in IMRT
Purpose: Current inverse planning methods for IMRT are limited because they
are not designed to explore the trade-offs between the competing objectives
between the tumor and normal tissues. Our goal was to develop an efficient
multiobjective optimization algorithm that was flexible enough to handle any
form of objective function and that resulted in a set of Pareto optimal plans.
Methods: We developed a hierarchical evolutionary multiobjective algorithm
designed to quickly generate a diverse Pareto optimal set of IMRT plans that
meet all clinical constraints and reflect the trade-offs in the plans. The top
level of the hierarchical algorithm is a multiobjective evolutionary algorithm
(MOEA). The genes of the individuals generated in the MOEA are the parameters
that define the penalty function minimized during an accelerated deterministic
IMRT optimization that represents the bottom level of the hierarchy. The MOEA
incorporates clinical criteria to restrict the search space through protocol
objectives and then uses Pareto optimality among the fitness objectives to
select individuals.
Results: Acceleration techniques implemented on both levels of the
hierarchical algorithm resulted in short, practical runtimes for optimizations.
The MOEA improvements were evaluated for example prostate cases with one target
and two OARs. The modified MOEA dominated 11.3% of plans using a standard
genetic algorithm package. By implementing domination advantage and protocol
objectives, small diverse populations of clinically acceptable plans that were
only dominated 0.2% by the Pareto front could be generated in a fraction of an
hour.
Conclusions: Our MOEA produces a diverse Pareto optimal set of plans that
meet all dosimetric protocol criteria in a feasible amount of time. It
optimizes not only beamlet intensities but also objective function parameters
on a patient-specific basis
Data for TROTS – The Radiotherapy Optimisation Test Set
The Radiotherapy Optimisation Test Set (TROTS) is an extensive set of problems originating from radiotherapy (radiation therapy) treatment planning. This dataset is created for 2 purposes: (1) to supply a large-scale dense dataset to measure performance and quality of mathematical solvers, and (2) to supply a dataset to investigate the multi-criteria optimisation and decision-making nature of the radiotherapy problem. The dataset contains 120 problems (patients), divided over 6 different treatment protocols/tumour types. Each problem contains numerical data, a configuration for the optimisation problem, and data required to visualise and interpret the results. The data is stored as HDF5 compatible Matlab files, and includes scripts to work with the dataset
Three-Dimensional Dose Prediction for Lung IMRT Patients with Deep Neural Networks: Robust Learning from Heterogeneous Beam Configurations
The use of neural networks to directly predict three-dimensional dose
distributions for automatic planning is becoming popular. However, the existing
methods only use patient anatomy as input and assume consistent beam
configuration for all patients in the training database. The purpose of this
work is to develop a more general model that, in addition to patient anatomy,
also considers variable beam configurations, to achieve a more comprehensive
automatic planning with a potentially easier clinical implementation, without
the need of training specific models for different beam settings
- …