28 research outputs found

    System integration of a fluoroscopic image calibration using robot assisted surgical guidance for distal locking process in closed intramedullary nailing of femur

    Get PDF
    Distal locking procedure is one of the most complex tasks in close intramedullary nailing operation which requires fluoroscopic image to interpret 2-D distal locking position on image related to 3-D distal locking position on the patient site. Hence the surgeon has to perform the distal locking process by using multiple fluoroscopic images which causes a lot of x-ray exposure to the patient and surgeon and is a time consuming task. This paper presents the system integration of a fluoroscopic image calibration using robot assisted surgical guidance. The system integration consists of three parts; distal locking recovery, fluoroscopic calibration and tracking, and robot assisted surgical guidance. The distal locking-hole recovery algorithm is based on characteristic information of the major and minor axes of distal locking hole. The fluoroscopic calibration and tracking is modeled as pin-hole projection model to estimate a projection equation based on optical tracking system. The robot-assisted surgical guidance is developed to overlay a trajectory path using a laser beam for reducing the problem of hand – eye coordination on most surgical navigation system. We integrate each part to complete a surgical navigation system for distal locking process. The experiment of system integration is conducted to validate the accuracy of distal locking axis position and orientation. The results of the system integration shows a mean angular error of 1.10 and mean Euclidean distance in X-Y plane error of 3.65 mm

    Fluoroscopy-based navigation system in spine surgery

    Full text link
    The variability in width, height, and spatial orientation of a spinal pedicle makes pedicle screw insertion a delicate operation. The aim of the current paper is to describe a computer-assisted surgical navigation system based on fluoroscopic X-ray image calibration and three-dimensional optical localizers in order to reduce radiation exposure while increasing accuracy and reliability of the surgical procedure for pedicle screw insertion. Instrumentation using transpedicular screw fixation was performed: in a first group, a conventional surgical procedure was carried out with 26 patients (138 screws); in a second group, a navigated surgical procedure (virtual fluoroscopy) was performed with 26 patients (140 screws). Evaluation of screw placement in every case was done by using plain X-rays and post-operative computer tomography scan. A 5 per cent cortex penetration (7 of 140 pedicle screws) occurred for the computer-assisted group. A 13 per cent penetration (18 of 138 pedicle screws) occurred for the non computer-assisted group. The radiation running time for each vertebra level (two screws) reached 3.5 s on average in the computer-assisted group and 11.5 s on average in the non computer-assisted group. The operative time for two screws on the same vertebra level reaches 10 min on average in the non computer-assisted group and 11.9 min on average in the computer-assisted group. The fluoroscopy-based (two-dimensional) navigation system for pedicle screw insertion is a safe and reliable procedure for surgery in the lower thoracic and lumbar spine

    Determination of intramedullary nail based on centerline adaptive registration

    Get PDF
    Objective: Internal fixation with intramedullary nails is a gold standard for the treatment of femoral shaft fractures. However, both the mismatch between intramedullary nails and the medullary cavity and inaccurate positioning of entry points will lead to deformation of intramedullary nails after implantation. The study aimed to determine a suitable intramedullary nail with an optimal entry point for a specific patient based on centerline adaptive registration.Method: A homotopic thinning algorithm is employed to extract centerlines of the femoral medullary cavity and the intramedullary nail. The two centerlines are registered to obtain a transformation. The medullary cavity and the intramedullary nail are registered based on the transformation. Next, a plane projection method is employed to calculate the surface points of the intramedullary nail laid outside the medullary cavity. According to the distribution of compenetration points, an iterative adaptive registration strategy is designed to decide an optimal position of the intramedullary nail in medullary cavity. The isthmus centerline is extended to the femur surface, where the entry point of the intramedullary nail is located. The suitability of an intramedullary nail for a specific patient was calculated by measuring the geometric quantities reflecting the interference between the femur and nail, and the suitability values of all nails are compared and the most suitable one is determined.Results: The growth experiment indicated that the bone to nail alignment is indeed affected by the extension of the isthmus centerline, including the extension direction and velocity. The geometrical experiment showed that this method could find the best registration position of intramedullary nails and select the optimal intramedullary nail for a specific patient. In the model experiments, the determined intramedullary nail could be successfully placed into the medullary cavity through the optimal entry point. A pre-screening tool to determine nails which can be successfully used has been given. In addition, the distal hole was accurately located within 14.28 s.Conclusion: These results suggest that the proposed method can select a suitable intramedullary nail with an optimal entry point. The position of the intramedullary nail can be determined in the medullary cavity, while deformation is avoided. The proposed method can determine the largest diameter intramedullary nail with as little damage to the intramedullary tissue as possible. The proposed method provides preparation aid for internal fixation with intramedullary nails guided by navigation systems or extracorporeal aimers

    Tibial Shaft Fractures:incidence, costs and outcome after intramedullary nailing

    Get PDF

    Tibial Shaft Fractures:incidence, costs and outcome after intramedullary nailing

    Get PDF

    Interventional 3D Augmented Reality in Orthopedic, Trauma and Vascular Surgery

    Get PDF
    The Medical Education, Training and Computer Assisted Interventions (METRICS) Laboratory aims to integrate novel mixed-reality technologies with application in computer assisted interventions. We showcase two technologies with specific aims at optimizing surgical workflow and minimizing radiation exposure in orthopedic, trauma, and vascular surgeries. The first is an Augmented Reality C-arm fluoroscope, which provides intuitive real-time visualization by accurately overlaying X-ray to video images. The second is a ‘Desired-views’ user interface which resolves the challenges involved in the optimal control of C-arm fluoroscopes for their constant repositioning during surgery by either the interventionalist or the surgical team

    Robust laparoscopic instruments tracking using colored strips

    Get PDF
    To assist surgeons in the acquisition of the required skills for the proper execution of the laparoscopic procedure, surgical simulators are used. During training with simulators it is useful to provide a surgical performance quantitative evaluation. Recent research works showed that such evaluation can be obtained by tracking the laparoscopic instruments, using only the images provided by the laparoscope and without hindering the surgical scene. In this work the state of the art method is improved so that a robust tracking can run even with the noisy background provided by realistic simulators. The method was validated by comparison with the tracking of a â\u80\u9cchess-boardâ\u80\u9d pattern and following tests were performed to check the robustness of the developed algorithm. Despite the noisy environment, the implemented method was found to be able to track the tip of the surgical instrument with a good accuracy compared to the other studies in the literature
    corecore