288 research outputs found

    Emerging technologies for the non-invasive characterization of physical-mechanical properties of tablets

    Get PDF
    The density, porosity, breaking force, viscoelastic properties, and the presence or absence of any structural defects or irregularities are important physical-mechanical quality attributes of popular solid dosage forms like tablets. The irregularities associated with these attributes may influence the drug product functionality. Thus, an accurate and efficient characterization of these properties is critical for successful development and manufacturing of a robust tablets. These properties are mainly analyzed and monitored with traditional pharmacopeial and non-pharmacopeial methods. Such methods are associated with several challenges such as lack of spatial resolution, efficiency, or sample-sparing attributes. Recent advances in technology, design, instrumentation, and software have led to the emergence of newer techniques for non-invasive characterization of physical-mechanical properties of tablets. These techniques include near infrared spectroscopy, Raman spectroscopy, X-ray microtomography, nuclear magnetic resonance (NMR) imaging, terahertz pulsed imaging, laser-induced breakdown spectroscopy, and various acoustic- and thermal-based techniques. Such state-of-the-art techniques are currently applied at various stages of development and manufacturing of tablets at industrial scale. Each technique has specific advantages or challenges with respect to operational efficiency and cost, compared to traditional analytical methods. Currently, most of these techniques are used as secondary analytical tools to support the traditional methods in characterizing or monitoring tablet quality attributes. Therefore, further development in the instrumentation and software, and studies on the applications are necessary for their adoption in routine analysis and monitoring of tablet physical-mechanical properties

    Multimodal photoacoustic and optical coherence tomography scanner using an all optical detection scheme for 3D morphological skin imaging

    Get PDF
    A noninvasive, multimodal photoacoustic and optical coherence tomography (PAT/OCT) scanner for three-dimensional in vivo (3D) skin imaging is described. The system employs an integrated, all optical detection scheme for both modalities in backward mode utilizing a shared 2D optical scanner with a field-of-view of ~13 × 13 mm2. The photoacoustic waves were detected using a Fabry Perot polymer film ultrasound sensor placed on the surface of the skin. The sensor is transparent in the spectral range 590-1200 nm. This permits the photoacoustic excitation beam (670-680 nm) and the OCT probe beam (1050 nm) to be transmitted through the sensor head and into the underlying tissue thus providing a backward mode imaging configuration. The respective OCT and PAT axial resolutions were 8 and 20 µm and the lateral resolutions were 18 and 50-100 µm. The system provides greater penetration depth than previous combined PA/OCT devices due to the longer wavelength of the OCT beam (1050 nm rather than 829-870 nm) and by operating in the tomographic rather than the optical resolution mode of photoacoustic imaging. Three-dimensional in vivo images of the vasculature and the surrounding tissue micro-morphology in murine and human skin were acquired. These studies demonstrated the complementary contrast and tissue information provided by each modality for high-resolution 3D imaging of vascular structures to depths of up to 5 mm. Potential applications include characterizing skin conditions such as tumors, vascular lesions, soft tissue damage such as burns and wounds, inflammatory conditions such as dermatitis and other superficial tissue abnormalities

    MEMS Technology for Biomedical Imaging Applications

    Get PDF
    Biomedical imaging is the key technique and process to create informative images of the human body or other organic structures for clinical purposes or medical science. Micro-electro-mechanical systems (MEMS) technology has demonstrated enormous potential in biomedical imaging applications due to its outstanding advantages of, for instance, miniaturization, high speed, higher resolution, and convenience of batch fabrication. There are many advancements and breakthroughs developing in the academic community, and there are a few challenges raised accordingly upon the designs, structures, fabrication, integration, and applications of MEMS for all kinds of biomedical imaging. This Special Issue aims to collate and showcase research papers, short commutations, perspectives, and insightful review articles from esteemed colleagues that demonstrate: (1) original works on the topic of MEMS components or devices based on various kinds of mechanisms for biomedical imaging; and (2) new developments and potentials of applying MEMS technology of any kind in biomedical imaging. The objective of this special session is to provide insightful information regarding the technological advancements for the researchers in the community

    Computational Inverse Problems

    Get PDF
    Inverse problem typically deal with the identification of unknown quantities from indirect measurements and appear in many areas in technology, medicine, biology, finance, and econometrics. The computational solution of such problems is a very active, interdisciplinary field with close connections to optimization, control theory, differential equations, asymptotic analysis, statistics, and probability. The focus of this workshop was on hybrid methods, model reduction, regularization in Banach spaces, and statistical approaches

    Imaging Sensors and Applications

    Get PDF
    In past decades, various sensor technologies have been used in all areas of our lives, thus improving our quality of life. In particular, imaging sensors have been widely applied in the development of various imaging approaches such as optical imaging, ultrasound imaging, X-ray imaging, and nuclear imaging, and contributed to achieve high sensitivity, miniaturization, and real-time imaging. These advanced image sensing technologies play an important role not only in the medical field but also in the industrial field. This Special Issue covers broad topics on imaging sensors and applications. The scope range of imaging sensors can be extended to novel imaging sensors and diverse imaging systems, including hardware and software advancements. Additionally, biomedical and nondestructive sensing applications are welcome

    The optical modelling and design of Fabry Perot Interferometer sensors for ultrasound detection

    Get PDF
    The work in this thesis documents the optical modelling and design of Fabry Perot Interferometer (FPI) sensors for the detection of ultrasonic waves. The ultrasonic waves modulate the optical phase of the beam through a change in the cavity spacing of the FPI sensor. The optical sensitivity is defined as the change in the reflected light per unit change in the cavity thickness. An optical model to simulate Interferometer Transfer Functions (ITFs) for a Gaussian beam propagating in a Fabry Perot Interferometer is implemented. An understanding of the Gaussian beam phase propagation in a Fabry Perot Interferometer is presented to help in explaining the shape of ITFs simulated. The model is experimentally validated. The model is applied as a design tool for the purpose of optimising FPI sensors. This is achieved by choosing the beam radii, mirror reflectivities and cavity spacing’s which lead to high optical sensitivity. A FPI sensor with high optical sensitivity and pressure linearity is achieved. A high pressure linearity can be achieved by creating a highly asymmetric ITF, by a combination of a highly diverging beam and aperturing the reflected beam. The understanding presented in this work helps in designing optimised FPI sensors for ultrasound detection, as well as in providing a general understanding of the effects of Gaussian beams or other types of divergent beams illuminating FPIs

    Design and fabrication of MOMS-based ultrasonic probes for minimally invasive endoscopic applications

    Get PDF
    A Micro-opto-mechanical systems (MOMS) based technology for the fabrication of ultrasonic probes on optical fiber is presented. Thanks to the high miniaturization level reached, the realization of an ultrasonic system constituted by ultrasonic generating and detecting elements, suitable for minimally invasive applications or Non Destructive Evaluation (NDE) of materials at high resolution, is demonstrated. The ultrasonic generation is realized by irradiating a highly absorbing carbon film patterned on silicon micromachined structures with a nanosecond pulsed laser source, generating a mechanical shock wave due to the thermal expansion of the film induced by optical energy conversion into heat. The short duration of the pulsed laser, together with an appropriate emitter design, assure high frequency and wide band ultrasonic generation. The acoustic detection is also realized on a MOMS device using an interferometric receiver, fabricated with a Fabry-Perot optical cavity realized by means of a patterned SU-8 and two Al metallization levels. In order to detect the ultrasonic waves, the cavity is interrogated by a laser beam measuring the reflected power with a photodiode. Various issues related to the design and fabrication of these acoustic probes are investigated in this thesis. First, theoretical models are developed to characterize the opto-acoustic behavior of the devices and estimate their expected acoustic performances. Tests structures are realized to derive the relevant physical parameters of the materials constituting the MOMS devices and determine the conditions theoretically assuring the best acoustic emission and detection performances. Moreover, by exploiting the models and the theoretical results, prototypes of acoustic probes are designed and their fabrication process developed by means of an extended experimental activity

    Long-Wavelength Infrared Thermophotonic Imaging of Demineralization in Dental Hard Tissue

    Get PDF
    Early detection of the most prevalent oral disease worldwide, i.e., dental caries, still remains as one of the major challenges in Dentistry. Current dental standard of care relies on caries detection methods which lack the sufficient specificity and sensitivity to detect caries at early stages of formation when they can be healed. In this thesis, a clinically and commercially viable thermophotonic imaging (TPI) technology capable of detecting early enamel caries using an inexpensive long-wavelength infrared (LWIR, 8-14m) camera is presented. Through theoretical modelling and experiments on standard samples, the enhanced diagnostic contrast in LWIR detection compared to existing MWIR detection technologies is verified. Diagnostic performance of the system and its detection threshold are experimentally evaluated by monitoring the inception and progression of artificially-induced occlusal and proximal caries as well as natural early caries. The results are suggestive of the suitability of the developed LWIR system for detecting early dental caries
    • …
    corecore