1,082 research outputs found
Recommended from our members
A Lower Limb Prosthesis with Active Alignment for Reduced Limb Loading
Over the past decade, the growing field of robotics has created new possibilities in lower limb prostheses. The focus of these new prostheses has been replicating the dynamics of the lost limb in order to restore gait of individuals with lower limb amputations to healthy norms. This places demanding loads on the residual limb. Compensation by the rest of body is high, causes overloading of intact joints and can lead to deterioration of mobility and overall health. Abnormalities remain present in the person’s gait, stemming from the loading of soft tissue and the altered anatomy of the affected limb. In this dissertation, an experimental prosthesis is developed with systematic, simulation based techniques. Kinematics and kinetics of the prosthesis design are altered in order to actively realign the limb in relation to the center of pressure during stance, allowing positive power to be generated by the prosthesis while actively reducing the magnitude of the sagittal moment transferred to the residual limb. Initial findings show that during walking with the experimental device compared to a daily use prosthesis, peak pressures on the residual limb are lowered by over 10% while maintaining walking speed
Dexter: A Smart Prosthetic Device for Transradial Amputees
Existing prosthetics require significant user input, inhibiting device function and convenience. An assistive intelligence that could “feel” and “see” its environment, perform grasps, and provide feedback without excessive user interaction would give everyday functionality back to the wearer. This device, called Dexter, is a below-the-elbow prosthesis that can adjust its position, orientation, and grip based on visual and force feedback to detect objects and perform everyday activities. Dexter is the first intelligent anthropomorphic hand for everyday use and advanced research applications alike and provides an inexpensive, intuitive, and intelligent alternative to existing prosthetic hands
On the development of a cybernetic prosthetic hand
The human hand is the end organ of the upper limb, which in humans serves the important
function of prehension, as well as being an important organ for sensation and communication.
It is a marvellous example of how a complex mechanism can be implemented,
capable of realizing very complex and useful tasks using a very effective combination of
mechanisms, sensing, actuation and control functions.
In this thesis, the road towards the realization of a cybernetic hand has been presented.
After a detailed analysis of the model, the human hand, a deep review of the state of the
art of artificial hands has been carried out. In particular, the performance of prosthetic
hands used in clinical practice has been compared with the research prototypes, both for
prosthetic and for robotic applications. By following a biomechatronic approach, i.e. by
comparing the characteristics of these hands with the natural model, the human hand, the
limitations of current artificial devices will be put in evidence, thus outlining the design
goals for a new cybernetic device.
Three hand prototypes with a high number of degrees of freedom have been realized and
tested: the first one uses microactuators embedded inside the structure of the fingers, and
the second and third prototypes exploit the concept of microactuation in order to increase
the dexterity of the hand while maintaining the simplicity for the control. In particular, a
framework for the definition and realization of the closed-loop electromyographic control of
these devices has been presented and implemented.
The results were quite promising, putting in evidence that, in the future, there could
be two different approaches for the realization of artificial devices. On one side there
could be the EMG-controlled hands, with compliant fingers but only one active degree of
freedom. On the other side, more performing artificial hands could be directly interfaced
with the peripheral nervous system, thus establishing a bi-directional communication with
the human brain
Impact of Ear Occlusion on In-Ear Sounds Generated by Intra-oral Behaviors
We conducted a case study with one volunteer and a recording setup to detect sounds induced by the actions: jaw clenching, tooth grinding, reading, eating, and drinking. The setup consisted of two in-ear microphones, where the left ear was semi-occluded with a commercially available earpiece and the right ear was occluded with a mouldable silicon ear piece. Investigations in the time and frequency domains demonstrated that for behaviors such as eating, tooth grinding, and reading, sounds could be recorded with both sensors. For jaw clenching, however, occluding the ear with a mouldable piece was necessary to enable its detection. This can be attributed to the fact that the mouldable ear piece sealed the ear canal and isolated it from the environment, resulting in a detectable change in pressure. In conclusion, our work suggests that detecting behaviors such as eating, grinding, reading with a semi-occluded ear is possible, whereas, behaviors such as clenching require the complete occlusion of the ear if the activity should be easily detectable. Nevertheless, the latter approach may limit real-world applicability because it hinders the hearing capabilities.</p
Fiber Bragg Gratings as e-Health Enablers: An Overview for Gait Analysis Applications
Nowadays, the fast advances in sensing technologies and ubiquitous wireless networking are reflected in medical practice. It provides new healthcare advantages under the scope of e-Health applications, enhancing life quality of citizens. The increase of life expectancy of current population comes with its challenges and growing health risks, which include locomotive problems. Such impairments and its rehabilitation require a close monitoring and continuous evaluation, which add financial burdens on an already overloaded healthcare system. Analysis of body movements and gait pattern can help in the rehabilitation of such problems. These monitoring systems should be noninvasive and comfortable, in order to not jeopardize the mobility and the day-to-day activities of citizens. The use of fiber Bragg gratings (FBGs) as e-Health enablers has presented itself as a new topic to be investigated, exploiting the FBGs’ advantages over its electronic counterparts. Although gait analysis has been widely assessed, the use of FBGs in biomechanics and rehabilitation is recent, with a wide field of applications. This chapter provides a review of the application of FBGs for gait analysis monitoring, namely its use in topics such as the monitoring of plantar pressure, angle, and torsion and its integration in rehabilitation exoskeletons and for prosthetic control
Recommended from our members
A Generalized Method for Predictive Simulation-Based Lower Limb Prosthesis Design
Lower limb prostheses are designed to replace the functions and form of the missing biological anatomy. These functions are hypothesized to improve user outcome measures which are negatively affected by receiving an amputation – such as metabolic cost of transport, preferred walking speed, and perceived discomfort during walking. However, the effect of these design functions on the targeted outcome measures is highly variable, suggesting that these relationships are not fully understood. Biomechanics simulation and modeling tools are increasingly capable of analyzing the effects of a design on the resulting user gait. In this work, prothesis-aided gait is optimized in simulation to reduce both muscle effort and peak loads on the residual limb using a generalized prosthesis model. Compared to a traditional revolute powered ankle joint model, a two degree-of freedom generalized model reduced muscle activations by 50% and peak loads by 15%. Simulated prosthesis behaviors corresponding to the optimal gait patterns were translated into a two degree-of-freedom ankle-foot prosthesis design with powered bidirectional linear translation and plantarflexion. The prototype is capable of delivering up to 171 N-m of plantarflexion torque and 499 N of translation force, with 15° dorsi-/35° plantarflexion and 10 cm translation range of motion. The mass and height of the ankle-foot are 2.29 kg and 19.5 cm, respectively. The mass of the entire system including the wearable offboard system is 8.58 kg. This platform is designed to emulate the behavior of the simulated prosthesis, as well as be configurable to emulate alternate behaviors obtained from simulations with different optimization objectives. The prototype is controlled to replicate simulated walking patterns using a high level finite state controller, mid-level stiffness controller, and low level load controller. Closed loop load control has bandwidth of 15 Hz in translation and 7.2 Hz in flexion. Load tracking during walking with a single able-bodied human subject ranges from 93 to 159 N in translation and 4.6 to 21.3 N-m in flexion. The contribution of this work is to provide a framework for predictive simulation-based prosthesis design, evidence of its practical implementation, and the experimental tools to validate future predictive simulation studies
A Robotic Ankle-Foot Prosthesis With Active Alignment
An ankle-foot prosthesis designed to mimic the missing physiological limb generates a large sagittal moment during push off which must be transferred to the residual limb through the socket connection. The large moment is correlated with high internal socket pressures that are often a source of discomfort for the person with amputation, limiting prosthesis use. In this paper, the concept of active alignment is developed. Active alignment realigns the affected residual limb toward the center of pressure (CoP) during stance. During gait, the prosthesis configuration changes to shorten the moment arm between the ground reaction force (GRF) and the residual limb. This reduces the peak moment transferred through the socket interface during late stance. A tethered robotic ankle prosthesis has been developed, and evaluation results are presented for active alignment during normal walking in a laboratory setting. Preliminary testing was performed with a subject without amputation walking with able-bodied adapters at a constant speed. The results show a 33% reduction in the peak resultant moment transferred at the socket limb interface
Investigation into the control of an upper-limb myoelectric prosthesis
SIGLEAvailable from British Library Document Supply Centre- DSC:DXN053608 / BLDSC - British Library Document Supply CentreGBUnited Kingdo
Novel Bidirectional Body - Machine Interface to Control Upper Limb Prosthesis
Objective. The journey of a bionic prosthetic user is characterized by the opportunities and limitations involved in adopting a device (the prosthesis) that should enable activities of daily living (ADL). Within this context, experiencing a bionic hand as a functional (and, possibly, embodied) limb constitutes the premise for mitigating the risk of its abandonment through the continuous use of the device. To achieve such a result, different aspects must be considered for making the artificial limb an effective support for carrying out ADLs. Among them, intuitive and robust control is fundamental to improving amputees’ quality of life using upper limb prostheses. Still, as artificial proprioception is essential to perceive the prosthesis movement without constant visual attention, a good control framework may not be enough to restore practical functionality to the limb. To overcome this, bidirectional communication between the user and the prosthesis has been recently introduced and is a requirement of utmost importance in developing prosthetic hands. Indeed, closing the control loop between the user and a prosthesis by providing artificial sensory feedback is a fundamental step towards the complete restoration of the lost sensory-motor functions. Within my PhD work, I proposed the development of a more controllable and sensitive human-like hand prosthesis, i.e., the Hannes prosthetic hand, to improve its usability and effectiveness.
Approach. To achieve the objectives of this thesis work, I developed a modular and scalable software and firmware architecture to control the Hannes prosthetic multi-Degree of Freedom (DoF) system and to fit all users’ needs (hand aperture, wrist rotation, and wrist flexion in different combinations). On top of this, I developed several Pattern Recognition (PR) algorithms to translate electromyographic (EMG) activity into complex movements. However, stability and repeatability were still unmet requirements in multi-DoF upper limb systems; hence, I started by investigating different strategies to produce a more robust control. To do this, EMG signals were collected from trans-radial amputees using an array of up to six sensors placed over the skin. Secondly, I developed a vibrotactile system to implement haptic feedback to restore proprioception and create a bidirectional connection between the user and the prosthesis. Similarly, I implemented an object stiffness detection to restore tactile sensation able to connect the user with the external word. This closed-loop control between EMG and vibration feedback is essential to implementing a Bidirectional Body - Machine Interface to impact amputees’ daily life strongly. For each of these three activities: (i) implementation of robust pattern recognition control algorithms, (ii) restoration of proprioception, and (iii) restoration of the feeling of the grasped object's stiffness, I performed a study where data from healthy subjects and amputees was collected, in order to demonstrate the efficacy and usability of my implementations. In each study, I evaluated both the algorithms and the subjects’ ability to use the prosthesis by means of the F1Score parameter (offline) and the Target Achievement Control test-TAC (online). With this test, I analyzed the error rate, path efficiency, and time efficiency in completing different tasks.
Main results. Among the several tested methods for Pattern Recognition, the Non-Linear Logistic Regression (NLR) resulted to be the best algorithm in terms of F1Score (99%, robustness), whereas the minimum number of electrodes needed for its functioning was determined to be 4 in the conducted offline analyses. Further, I demonstrated that its low computational burden allowed its implementation and integration on a microcontroller running at a sampling frequency of 300Hz (efficiency). Finally, the online implementation allowed the subject to simultaneously control the Hannes prosthesis DoFs, in a bioinspired and human-like way. In addition, I performed further tests with the same NLR-based control by endowing it with closed-loop proprioceptive feedback. In this scenario, the results achieved during the TAC test obtained an error rate of 15% and a path efficiency of 60% in experiments where no sources of information were available (no visual and no audio feedback). Such results demonstrated an improvement in the controllability of the system with an impact on user experience.
Significance. The obtained results confirmed the hypothesis of improving robustness and efficiency of a prosthetic control thanks to of the implemented closed-loop approach. The bidirectional communication between the user and the prosthesis is capable to restore the loss of sensory functionality, with promising implications on direct translation in the clinical practice
AI and Prosthetics
Prosthetics are very important to an amputee.The introduction of technology to prosthetics has allowed bionic limbs to emerge and change the way we were thinking about prosthetic limbs.More and more companies create new innovative models,but not affordable for anyone.3D Printing gives more options
- …