15,414 research outputs found

    Modeling, Simulation and Control of Wind Diesel Power Systems

    Get PDF
    Wind diesel power systems (WDPSs) are isolated microgrids that combine diesel generators (DGs) with wind turbine generators (WTGs). Often, WDPS are the result of adding WTGs to a previous existing diesel power plant located in a remote place where there is an available wind resource. By means of power supplied by WTGs, fuel consumption and CO2 emissions are reduced. WDPSs are isolated power systems with low inertia where important system frequency and voltage variations occur. WDPS dynamic modeling and simulation allows short-term simulations to be carried out to obtain detailed electrical variable transients so that WDPS stability and power quality can be tested. This book includes papers on several subjects regarding WDPSs: the main topic of interest is WDPS dynamic modeling and simulation, but related areas such as the sizing of the different WDPS components, studies concerning the control of WDPSs or the use of energy storage systems (ESSs) in WDPSs and the benefits that ESSs provide to WDPS are also discussed. The book also deals with related AC isolated microgrids, such as wind-hydro microgrids or wind-photovoltaic-diesel microgrids

    The Global Star-Formation Law by Supernova Feedback

    Full text link
    We address a simple model where the Kennicutt-Schmidt (KS) relation between the macroscopic densities of star-formation rate (SFR, ρsfr\rho_{\rm sfr}) and gas (nn) in galactic discs emerges from self-regulation of the SFR via supernova feedback. It arises from the physics of supernova bubbles, insensitive to the microscopic SFR recipe and not explicitly dependent on gravity. The key is that the filling factor of SFR-suppressed supernova bubbles self-regulates to a constant, f0.5f\sim 0.5. Expressing the bubble fading radius and time in terms of nn, the filling factor is fSnsf \propto S\,n^{-s} with s1.5s\sim 1.5, where SS is the supernova rate density. A constant ff thus refers to ρsfrn1.5\rho_{\rm sfr} \propto n^{1.5}, with a density-independent SFR efficiency per free-fall time 0.01\sim 0.01. The self-regulation to f0.5f \sim 0.5 and the convergence to a KS relation independent of the local SFR recipe are demonstrated in cosmological and isolated-galaxy simulations using different codes and recipes. In parallel, the spherical analysis of bubble evolution is generalized to clustered supernovae, analytically and via simulations, yielding s1.5±0.5s \simeq 1.5 \pm 0.5. An analysis of photo-ionized bubbles about pre-supernova stars yields a range of KS slopes but the KS relation is dominated by the supernova bubbles. Superbubble blowouts may lead to an alternative self-regulation by outflows and recycling. While the model is over-simplified, its simplicity and validity in the simulations may argue that it captures the origin of the KS relation

    Development of a renewable hybrid power plant with extended utilization of pumped storage unit equipment

    Get PDF
    The scheme of a renewable hybrid power plant with the extended use of the installed equipment of the pumped storage unit for the conversion of the photovoltaic and wind generators direct current to the alternating one is proposed. The scheme is based on existing components with widely used proven technology. To output the power of solar and wind generators to the grid and for DC to AC conversion, a synchronous generator of the pumped storage unit is used in addition to grid inverters. An induction motor, powered through a variable frequency drive from a common DC bus, is used together with a hydraulic turbine to rotate the generator. In addition, batteries and capacitors banks are connected to the DC bus. The possibility of using various types of electric machines to drive a synchronous generator is analyzed and the preference of an induction motor is shown. The response of an induction motor to rotational speed fluctuations is modeled and its capability to participate in the network frequency regulation is shown. With the example of a typical daily load and generation profile, it is shown that the proposed solution for DC to AC conversion has an efficiency close to that of the grid inverter. The proposed scheme of the hybrid power plant can increase the reliability of renewable energy sources and the stability of the network frequency. This is achieved due to increasing the inertia of the rotating masses in the power system, the power factor control capabilities of the synchronous generator and the proper response of induction motor to rapid fluctuations of the rotation speed. The creation of such hybrid power plants opens the way for a further increase in the share of renewable energy sources in the power system.Запропоновано схему гібридної відновлюваної електричної станції з розширеним використанням встановленого обладнання гідроакумулюючого блока для перетворення постійного струму фотоелектричних та вітрових генераторів в змінний. Схема базується на наявних компонентах з широко використовуваною відпрацьованою технологією. Для видачі потужності та перетворення постійного струму сонячних та вітрових генераторів в змінний окрім мережевих інверторів використовується синхронний генератор гідроакумулюючого блоку. Для обертання генератора крім гідротурбіни також використовується асинхронний двигун, підключений через частотно-регульований привод до загальної шини постійного струму станції. Крім того, до шини постійного струму підключені електрохімічні акумулятори і батареї конденсаторів. Проаналізовано можливість використання різних типів електричних машин для приводу синхронного генератора і показано перевагу асинхронного двигуна. Змодельовано реакцію асинхронного двигуна на коливання швидкості обертання і показано його здатність брати участь в регулюванні частоти мережі. На прикладі типового добового графіка навантаження і генерації показано, що запропоноване рішення по перетворенню постійного струму в змінний має ККД, близький до ККД мережевого інвертора. Запропонована схема гібридної станції дозволяє підвищити надійність роботи відновлюваних джерел енергії і стабільність частоти мережі. Це досягається завдяки збільшенню інерції обертових мас в енергосистемі, можливості управління коефіцієнтом потужності синхронного генератора і властивій асинхронному двигуну реакції на коливання швидкості обертання. Створення таких гібридних станцій відкриває шлях до подальшого збільшення частки відновлюваних джерел в енергосистемі

    Wind Power: The Economic Impact of Intermittency

    Get PDF
    Wind is the fastest growing renewable energy source for generating electricity, but economic research lags behind. In this study, therefore, we examine the economics of integrating large-scale wind energy into an existing electrical grid. Using a simple grid management model to investigate the impact of various levels of wind penetration on grid management costs, we show that costs of reducing CO2 emissions by relying more on wind power depend on the generation mix of the existing electrical grid and the degree of wind penetration, with costs ranging from 44towellover44 to well over 1000 per tonne of CO2 reduced. Costs are lowest if wind displaces large amounts of fossil fuel production and there is some hydroelectric power to act as a buffer. Hydro capacity has the ability to store wind generated power for use at more opportune times. If wind does nothing more than replace hydro or nuclear power, however, the environmental benefits (reduced CO2 emissions) of investing in wind power are smal

    Energy Production Analysis and Optimization of Mini-Grid in Remote Areas: The Case Study of Habaswein, Kenya

    Get PDF
    Rural electrification in remote areas of developing countries has several challenges which hinder energy access to the population. For instance, the extension of the national grid to provide electricity in these areas is largely not viable. The Kenyan Government has put a target to achieve universal energy access by the year 2020. To realize this objective, the focus of the program is being shifted to establishing off-grid power stations in rural areas. Among rural areas to be electrified is Habaswein, which is a settlement in Kenya’s northeastern region without connection to the national power grid, and where Kenya Power installed a stand-alone hybrid mini-grid. Based on field observations, power generation data analysis, evaluation of the potential energy resources and simulations, this research intends to evaluate the performance of the Habaswein mini-grid and optimize the existing hybrid generation system to enhance its reliability and reduce the operation costs. The result will be a suggestion of how Kenyan rural areas could be sustainably electrified by using renewable energy based off-grid power stations. It will contribute to bridge the current research gap in this area, and it will be a vital tool to researchers, implementers and the policy makers in energy sector

    Comparison between unipolar and bipolar single phase grid-connected inverters for PV applications

    Get PDF
    An inverter is essential for the interfacing of photovoltaic panels with the AC network. There are many possible inverter topologies and inverter switching schemes and each one will have its own relative advantages and disadvantages. Efficiency and output current distortion are two important factors governing the choice of inverter system. In this paper, it is argued that current controlled inverters offer significant advantages from the point of view of minimisation of current distortion. Two inverter switching strategies are explored in detail. These are the unipolar current controlled inverter and the bipolar current controlled inverter. With respect to low frequency distortion, previously published works provide theoretical arguments in favour of bipolar switching. On the other hand it has also been argued that the unipolar switched inverter offers reduced switching losses and generates less EMI. On efficiency grounds, it appears that the unipolar switched inverter has an advantage. However, experimental results presented in this paper show that the level of low frequency current distortion in the unipolar switched inverter is such that it can only comply with Australian Standard 4777.2 above a minimum output current. On the other hand it is shown that at the same current levels bipolar switching results in reduced low frequency harmonics

    Comparison between unipolar and bipolar single phase grid-connected inverters for PV applications

    Get PDF
    An inverter is essential for the interfacing of photovoltaic panels with the AC network. There are many possible inverter topologies and inverter switching schemes and each one will have its own relative advantages and disadvantages. Efficiency and output current distortion are two important factors governing the choice of inverter system. In this paper, it is argued that current controlled inverters offer significant advantages from the point of view of minimisation of current distortion. Two inverter switching strategies are explored in detail. These are the unipolar current controlled inverter and the bipolar current controlled inverter. With respect to low frequency distortion, previously published works provide theoretical arguments in favour of bipolar switching. On the other hand it has also been argued that the unipolar switched inverter offers reduced switching losses and generates less EMI. On efficiency grounds, it appears that the unipolar switched inverter has an advantage. However, experimental results presented in this paper show that the level of low frequency current distortion in the unipolar switched inverter is such that it can only comply with Australian Standard 4777.2 above a minimum output current. On the other hand it is shown that at the same current levels bipolar switching results in reduced low frequency harmonics

    Wind Power: The Economic Impact of Intermittency

    Get PDF
    Wind is the fastest growing renewable energy source for generating electricity, but economic research lags behind. In this study, therefore, we examine the economics of integrating large-scale wind energy into an existing electrical grid. Using a simple grid management model to investigate the impact of various levels of wind penetration on grid management costs, we show that costs of reducing CO2 emissions by relying more on wind power depend on the generation mix of the existing electricity grid and the degree of wind penetration, with costs ranging from 21towellover21 to well over 1000 per tonne of CO2 reduced. Costs are lowest if wind displaces large amounts of fossil fuel production and there is some hydroelectric power to act as a buffer. Hydro capacity has the ability to store wind generated power for use at more opportune times. If wind does nothing more than replace hydro or nuclear power then the environmental benefits (reduced CO2 emissions) of investing in wind power are small.Wind power, carbon costs, electricity grids, mathematical programming
    corecore