9,718 research outputs found

    One-Cycle Zero-Integral-Error Current Control for Shunt Active Power Filters

    Get PDF
    [EN] Current control has, for decades, been one of the more challenging research fields in the development of power converters. Simple and robust nonlinear methods like hysteresis or sigma-delta controllers have been commonly used, while sophisticated linear controllers based on classical control theory have been developed for PWM-based converters. The one-cycle current control technique is a nonlinear technique based on cycle-by-cycle calculation of the ON time of the converter switches for the next switching period. This kind of controller requires accurate measurement of voltages and currents in order achieve a precise current tracking. These techniques have been frequently used in the control of power converters generating low-frequency currents, where the reference varies slowly compared with the switching frequency. Its application is not so common in active power filter current controllers due to the fast variation of the references that demands not only accurate measurements but also high-speed computing. This paper proposes a novel one-cycle digital current controller based on the minimization of the integral error of the current. Its application in a three-leg four-wire shunt active power filter is presented, including a stability analysis considering the switching pattern selection. Furthermore, simulated and experimental results are presented to validate the proposed controller.Orts-Grau, S.; Balaguer-Herrero, P.; Alfonso-Gil, JC.; Martínez-Márquez, CI.; Gimeno Sales, FJ.; Segui-Chilet, S. (2020). One-Cycle Zero-Integral-Error Current Control for Shunt Active Power Filters. Electronics. 9(12):1-16. https://doi.org/10.3390/electronics9122008S116912Orts-Grau, S., Gimeno-Sales, F. J., Abellan-Garcia, A., Segui-Chilet, S., & Alfonso-Gil, J. C. (2010). Improved Shunt Active Power Compensator for IEEE Standard 1459 Compliance. IEEE Transactions on Power Delivery, 25(4), 2692-2701. doi:10.1109/tpwrd.2010.2049033Orts-Grau, S., Gimeno-Sales, F. J., Segui-Chilet, S., Abellan-Garcia, A., Alcaniz-Fillol, M., & Masot-Peris, R. (2009). Selective Compensation in Four-Wire Electric Systems Based on a New Equivalent Conductance Approach. IEEE Transactions on Industrial Electronics, 56(8), 2862-2874. doi:10.1109/tie.2009.2014368Trinh, Q.-N., & Lee, H.-H. (2013). An Advanced Current Control Strategy for Three-Phase Shunt Active Power Filters. IEEE Transactions on Industrial Electronics, 60(12), 5400-5410. doi:10.1109/tie.2012.2229677Bosch, S., Staiger, J., & Steinhart, H. (2018). Predictive Current Control for an Active Power Filter With LCL-Filter. IEEE Transactions on Industrial Electronics, 65(6), 4943-4952. doi:10.1109/tie.2017.2772176Balasubramanian, R., Parkavikathirvelu, K., Sankaran, R., & Amirtharajan, R. (2019). Design, Simulation and Hardware Implementation of Shunt Hybrid Compensator Using Synchronous Rotating Reference Frame (SRRF)-Based Control Technique. Electronics, 8(1), 42. doi:10.3390/electronics8010042Imam, A. A., Sreerama Kumar, R., & Al-Turki, Y. A. (2020). Modeling and Simulation of a PI Controlled Shunt Active Power Filter for Power Quality Enhancement Based on P-Q Theory. Electronics, 9(4), 637. doi:10.3390/electronics9040637Panigrahi, R., Subudhi, B., & Panda, P. C. (2016). A Robust LQG Servo Control Strategy of Shunt-Active Power Filter for Power Quality Enhancement. IEEE Transactions on Power Electronics, 31(4), 2860-2869. doi:10.1109/tpel.2015.2456155Herman, L., Papic, I., & Blazic, B. (2014). A Proportional-Resonant Current Controller for Selective Harmonic Compensation in a Hybrid Active Power Filter. IEEE Transactions on Power Delivery, 29(5), 2055-2065. doi:10.1109/tpwrd.2014.2344770Panigrahi, R., & Subudhi, B. (2017). Performance Enhancement of Shunt Active Power Filter Using a Kalman Filter-Based H{{{\rm H}}_\infty } Control Strategy. IEEE Transactions on Power Electronics, 32(4), 2622-2630. doi:10.1109/tpel.2016.2572142Jiang, W., Ding, X., Ni, Y., Wang, J., Wang, L., & Ma, W. (2018). An Improved Deadbeat Control for a Three-Phase Three-Line Active Power Filter With Current-Tracking Error Compensation. IEEE Transactions on Power Electronics, 33(3), 2061-2072. doi:10.1109/tpel.2017.2693325Buso, S., Caldognetto, T., & Brandao, D. (2015). Dead-Beat Current Controller for Voltage Source Converters with Improved Large Signal Response. IEEE Transactions on Industry Applications, 1-1. doi:10.1109/tia.2015.2488644Tarisciotti, L., Formentini, A., Gaeta, A., Degano, M., Zanchetta, P., Rabbeni, R., & Pucci, M. (2017). Model Predictive Control for Shunt Active Filters With Fixed Switching Frequency. IEEE Transactions on Industry Applications, 53(1), 296-304. doi:10.1109/tia.2016.2606364Kumar, M., & Gupta, R. (2017). Sampled-Time-Domain Analysis of a Digitally Implemented Current Controlled Inverter. IEEE Transactions on Industrial Electronics, 64(1), 217-227. doi:10.1109/tie.2016.2609840Ho, C. N.-M., Cheung, V. S. P., & Chung, H. S.-H. (2009). Constant-Frequency Hysteresis Current Control of Grid-Connected VSI Without Bandwidth Control. IEEE Transactions on Power Electronics, 24(11), 2484-2495. doi:10.1109/tpel.2009.2031804Wu, F., Feng, F., Luo, L., Duan, J., & Sun, L. (2015). Sampling period online adjusting-based hysteresis current control without band with constant switching frequency. IEEE Transactions on Industrial Electronics, 62(1), 270-277. doi:10.1109/tie.2014.2326992Holmes, D. G., Davoodnezhad, R., & McGrath, B. P. (2013). An Improved Three-Phase Variable-Band Hysteresis Current Regulator. IEEE Transactions on Power Electronics, 28(1), 441-450. doi:10.1109/tpel.2012.2199133Komurcugil, H., Bayhan, S., & Abu-Rub, H. (2017). Variable- and Fixed-Switching-Frequency-Based HCC Methods for Grid-Connected VSI With Active Damping and Zero Steady-State Error. IEEE Transactions on Industrial Electronics, 64(9), 7009-7018. doi:10.1109/tie.2017.2686331Chang, C.-H., Wu, F.-Y., & Chen, Y.-M. (2012). Modularized Bidirectional Grid-Connected Inverter With Constant-Frequency Asynchronous Sigma–Delta Modulation. IEEE Transactions on Industrial Electronics, 59(11), 4088-4100. doi:10.1109/tie.2011.2176693Mertens, A. (1994). Performance analysis of three-phase inverters controlled by synchronous delta-modulation systems. IEEE Transactions on Industry Applications, 30(4), 1016-1027. doi:10.1109/28.297919Morales, J., de Vicuna, L. G., Guzman, R., Castilla, M., & Miret, J. (2018). Modeling and Sliding Mode Control for Three-Phase Active Power Filters Using the Vector Operation Technique. IEEE Transactions on Industrial Electronics, 65(9), 6828-6838. doi:10.1109/tie.2018.2795528Guzman, R., de Vicuna, L. G., Morales, J., Castilla, M., & Miret, J. (2016). Model-Based Control for a Three-Phase Shunt Active Power Filter. IEEE Transactions on Industrial Electronics, 63(7), 3998-4007. doi:10.1109/tie.2016.2540580Pichan, M., & Rastegar, H. (2017). Sliding-Mode Control of Four-Leg Inverter With Fixed Switching Frequency for Uninterruptible Power Supply Applications. IEEE Transactions on Industrial Electronics, 64(8), 6805-6814. doi:10.1109/tie.2017.2686346E. S., S., E. K., P., Chatterjee, K., & Bandyopadhyay, S. (2014). An Active Harmonic Filter Based on One-Cycle Control. IEEE Transactions on Industrial Electronics, 61(8), 3799-3809. doi:10.1109/tie.2013.2286558Wang, L., Han, X., Ren, C., Yang, Y., & Wang, P. (2018). A Modified One-Cycle-Control-Based Active Power Filter for Harmonic Compensation. IEEE Transactions on Industrial Electronics, 65(1), 738-748. doi:10.1109/tie.2017.2682021Jin, T., & Smedley, K. M. (2006). Operation of One-Cycle Controlled Three-Phase Active Power Filter With Unbalanced Source and Load. IEEE Transactions on Power Electronics, 21(5), 1403-1412. doi:10.1109/tpel.2006.880264Hirve, S., Chatterjee, K., Fernandes, B. G., Imayavaramban, M., & Dwari, S. (2007). PLL-Less Active Power Filter Based on One-Cycle Control for Compensating Unbalanced Loads in Three-Phase Four-Wire System. IEEE Transactions on Power Delivery, 22(4), 2457-2465. doi:10.1109/tpwrd.2007.893450Qiao, C., Smedley, K. M., & Maddaleno, F. (2004). A Single-Phase Active Power Filter With One-Cycle Control Under Unipolar Operation. IEEE Transactions on Circuits and Systems I: Regular Papers, 51(8), 1623-1630. doi:10.1109/tcsi.2004.832801Qiao, C., Jin, T., & MaSmedley, K. (2004). One-Cycle Control of Three-Phase Active Power Filter With Vector Operation. IEEE Transactions on Industrial Electronics, 51(2), 455-463. doi:10.1109/tie.2004.82522

    Two-leg three-phase inverter control for STATCOM and SSSC applications

    Get PDF
    Flexible ac transmission systems (FACTS) devices are attracting an increasing interest both in power system academic research and in electric utilities for their capabilities to improve steady-state performance as well as system stability. Several converter topologies for FACTS applications have been proposed in the recent literature, even if those based upon voltage source inverters (VSI) seem to be more attractive due to their intrinsic capability to rapidly respond to network changes such as perturbations subsequent to a fault and their property of being immune to resonance problem. In this paper, a new topology for inverter-based FACTS is proposed. This configuration, employing a two-leg three-phase inverter is employed for both series and parallel-connected reactive power compensators. The converter utilizes a modular topology for allowing a satisfaction of electronic components rating. A control strategy based on variable structure control technique with sliding mode is employed to track appropriate reference quantities. Design and control, as well as good tracking performances, are also verified through numerical simulations

    A survey on fractional order control techniques for unmanned aerial and ground vehicles

    Get PDF
    In recent years, numerous applications of science and engineering for modeling and control of unmanned aerial vehicles (UAVs) and unmanned ground vehicles (UGVs) systems based on fractional calculus have been realized. The extra fractional order derivative terms allow to optimizing the performance of the systems. The review presented in this paper focuses on the control problems of the UAVs and UGVs that have been addressed by the fractional order techniques over the last decade

    STEROWANIE ORAZ SYNCHRONIZACJA DWUPOZIOMOWEGO FALOWNIKA NAPIĘCIA W WARUNKACH PRZEJŚCIOWEJ ASYMETRII NAPIĘĆ SIECI

    Get PDF
    This paper presents the operation of grid tied, two level voltage source inverter (VSI) during network voltage unbalance. The control system was implemented in synchronous rotating reference frame dq0 (SRF). Two types of control structures were investigated herein. First utilizes the Double Decoupled SRF Phase-locked loop (DDSRF-PLL) synchronisation with positive and negative sequence currents control. Second one is simplified system that does not provide symmetrical components decomposition and decoupling for synchronisation. Simulation results exhibited a superior performance of the DDSRF-PLL control system under grid voltage unbalance.Niniejszy artykuł przedstawia pracę dwupoziomowego falownika napięcia współpracującego z siecią, podczas przejściowej asymetrii napięć. System sterowania został zaimplementowany w wirującym układzie synchronicznym dq0. Przeanalizowano dwa typy sterowania. W pierwszym zastosowano metodę synchronizacji z odprzęganiem DDSRF-PLL wraz z możliwością kontroli prądów składowej zgodnej i przeciwnej. Drugi natomiast w swoje uproszczeni formie nie pozwalała na sterowanie obu składowych symetrycznych, zabrakło również odprzęgania podczas synchronizacji z siecią. Wyniki symulacji pokazały o wiele lepsze działanie pierwszej metody sterowania

    A Comprehensive Survey on Different Control Strategies and Applications of Active Power Filters for Power Quality Improvement

    Get PDF
    This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).Power quality (PQ) has become an important topic in today’s power system scenario. PQ issues are raised not only in normal three-phase systems but also with the incorporation of different distributed generations (DGs), including renewable energy sources, storage systems, and other systems like diesel generators, fuel cells, etc. The prevalence of these issues comes from the non-linear features and rapid changing of power electronics devices, such as switch-mode converters for adjustable speed drives and diode or thyristor rectifiers. The wide use of these fast switching devices in the utility system leads to an increase in disturbances associated with harmonics and reactive power. The occurrence of PQ disturbances in turn creates several unwanted effects on the utility system. Therefore, many researchers are working on the enhancement of PQ using different custom power devices (CPDs). In this work, the authors highlight the significance of the PQ in the utility network, its effect, and its solution, using different CPDs, such as passive, active, and hybrid filters. Further, the authors point out several compensation strategies, including reference signal generation and gating signal strategies. In addition, this paper also presents the role of the active power filter (APF) in different DG systems. Some technical and economic considerations and future developments are also discussed in this literature. For easy reference, a volume of journals of more than 140 publications on this particular subject is reported. The effectiveness of this research work will boost researchers’ ability to select proper control methodology and compensation strategy for various applications of APFs for improving PQ.publishedVersio

    Regulatori struje aktivnih filtara snage za poboljšanje kvalitete snage: Tehnička analiza

    Get PDF
    Non-linear load deteriorates the quality of current waveforms at the point of common coupling of various consumers. Active power filter (APFs) is used to mitigate the most concern harmonic pollution in an electrical network. The controller part is the nucleus of an active power filter configuration. Active power filter performance is affected significantly by the selection of current control techniques. The active filter and its current control must have the capability to track sudden slope variations in the current reference to compensate the distorted current drawn by the voltage source inverter. Therefore, the choice and implementation of the current regulator is more important for the achievement of a satisfactory performance level. In this survey, technical reviews of various types of controllers covering a wide range have been presented. This work also reveals the advantages and disadvantages of the practiced control strategies. The effectiveness of the study will help the researchers to choose the proper control methods for various applicationsof active power filter.Nelinearni tereti pogoršavaju kvalitetu strujnih valova u točki u kojoj se spaja više potrošača. Aktivni filtar snage se koristi za ublažavanje najvažnijeg harmoničkog onečišćenja strujne mreže. Jezgra aktivnog filtra snage je regulator. Na performanse aktivnog filtra snage značajno utječe odabir upravljačke tehnike. Aktivni filtar i njegova tehnika upravljanja strujom moraju imati mogućnost pratiti nagle skokove u referentnoj vrijednosti struje kako bi mogli kompenzirati izobličenja struje koju vuče inverter naponskog izvora. Zato su izbor i implementacija regulatora struje iznimno važni za postizanje zadovoljavajuće razine performansi. U ovom pregledu su predstavljene tehničke recenzije koje pokrivaju širok raspon regulatora. Ovaj rad također otkriva prednosti i mane korištenih strategija upravljanja. Efektivnost ovog pregleda pomoći će istraživačima da izaberu ispravnu metodu upravljanja za različite aplikacije aktivnog filtra snage

    Regulatori struje aktivnih filtara snage za poboljšanje kvalitete snage: Tehnička analiza

    Get PDF
    Non-linear load deteriorates the quality of current waveforms at the point of common coupling of various consumers. Active power filter (APFs) is used to mitigate the most concern harmonic pollution in an electrical network. The controller part is the nucleus of an active power filter configuration. Active power filter performance is affected significantly by the selection of current control techniques. The active filter and its current control must have the capability to track sudden slope variations in the current reference to compensate the distorted current drawn by the voltage source inverter. Therefore, the choice and implementation of the current regulator is more important for the achievement of a satisfactory performance level. In this survey, technical reviews of various types of controllers covering a wide range have been presented. This work also reveals the advantages and disadvantages of the practiced control strategies. The effectiveness of the study will help the researchers to choose the proper control methods for various applicationsof active power filter.Nelinearni tereti pogoršavaju kvalitetu strujnih valova u točki u kojoj se spaja više potrošača. Aktivni filtar snage se koristi za ublažavanje najvažnijeg harmoničkog onečišćenja strujne mreže. Jezgra aktivnog filtra snage je regulator. Na performanse aktivnog filtra snage značajno utječe odabir upravljačke tehnike. Aktivni filtar i njegova tehnika upravljanja strujom moraju imati mogućnost pratiti nagle skokove u referentnoj vrijednosti struje kako bi mogli kompenzirati izobličenja struje koju vuče inverter naponskog izvora. Zato su izbor i implementacija regulatora struje iznimno važni za postizanje zadovoljavajuće razine performansi. U ovom pregledu su predstavljene tehničke recenzije koje pokrivaju širok raspon regulatora. Ovaj rad također otkriva prednosti i mane korištenih strategija upravljanja. Efektivnost ovog pregleda pomoći će istraživačima da izaberu ispravnu metodu upravljanja za različite aplikacije aktivnog filtra snage

    Finite control set model predictive control for a three-phase shunt active power filter with a kalman filter-based estimation

    Get PDF
    In this paper, the finite control set model predictive control is combined with the vector operation technique to be applied in the control of a three-phase active power filter. Typically, in the finite control set technique applied to three-phase power converters, eight different vectors are considered in order to obtain the optimum control signal by minimizing a cost function. On the other hand, the vector operation technique is based on dividing the grid voltage period into six different regions. The main advantage of combining both techniques is that for each region the number of possible voltage vectors to be considered can be reduced to a half, thus reducing the computational load employed by the control algorithm. Besides, in each region, only two phase-legs are switching at high frequency while the remaining phase-leg is maintained to a constant dc-voltage value during this interval. Accordingly, a reduction of the switching losses is obtained. Unlike the typical model predictive control methods which make use of the discrete differential equations of the converter, this method considers a Kalman filter in order to improve the behavior of the closed-loop system in noisy environments. Selected experimental results are exposed in order the demonstrate the validity of the control proposalPostprint (published version

    Mitigation of Power Quality Problems Using Custom Power Devices: A Review

    Get PDF
    Electrical power quality (EPQ) in distribution systems is a critical issue for commercial, industrial and residential applications. The new concept of advanced power electronic based Custom Power Devices (CPDs) mainly distributed static synchronous compensator (D-STATCOM), dynamic voltage restorer (DVR) and unified power quality conditioner (UPQC) have been developed due to lacking the performance of traditional compensating devices to minimize power quality disturbances. This paper presents a comprehensive review on D-STATCOM, DVR and UPQC to solve the electrical power quality problems of the distribution networks. This is intended to present a broad overview of the various possible DSTATCOM, DVR and UPQC configurations for single-phase (two wire) and three-phase (three-wire and four-wire) networks and control strategies for the compensation of various power quality disturbances. Apart from this, comprehensive explanation, comparison, and discussion on D-STATCOM, DVR, and UPQC are presented. This paper is aimed to explore a broad prospective on the status of D-STATCOMs, DVRs, and UPQCs to researchers, engineers and the community dealing with the power quality enhancement. A classified list of some latest research publications on the topic is also appended for a quick reference

    Applications of Power Electronics:Volume 1

    Get PDF
    corecore