960,754 research outputs found

    Biplane Fluoroscopy for Hindfoot Motion Analysis during Gait: A Model-based Evaluation

    Get PDF
    The purpose of this study was to quantify the accuracy and precision of a biplane fluoroscopy system for model-based tracking of in vivo hindfoot motion during over-ground gait. Gait was simulated by manually manipulating a cadaver foot specimen through a biplane fluoroscopy system attached to a walkway. Three 1.6-mm diameter steel beads were implanted into the specimen to provide marker-based tracking measurements for comparison to model-based tracking. A CT scan was acquired to define a gold standard of implanted bead positions and to create 3D models for model-based tracking. Static and dynamic trials manipulating the specimen through the capture volume were performed. Marker-based tracking error was calculated relative to the gold standard implanted bead positions. The bias, precision, and root-mean-squared (RMS) error of model-based tracking was calculated relative to the marker-based measurements. The overall RMS error of the model-based tracking method averaged 0.43 ± 0.22 mm and 0.66 ± 0.43° for static and 0.59 ± 0.10 mm and 0.71 ± 0.12° for dynamic trials. The model-based tracking approach represents a non-invasive technique for accurately measuring dynamic hindfoot joint motion during in vivo, weight bearing conditions. The model-based tracking method is recommended for application on the basis of the study results

    Model-based vs. model-free visual servoing: A Performance evaluation in microsystems

    Get PDF
    In this paper, model-based and model-free image based visual servoing (VS) approaches are implemented on a microassembly workstation, and their regulation and tracking performances are evaluated. A precise image based VS relies on computation of the image jacobian. In the model-based visual servoing, the image Jacobian is computed via calibrating the optical system. Precisely calibrated model based VS promises better positioning and tracking performance than the model-free approach. However, in the model-free approach, optical system calibration is not required due to the dynamic Jacobian estimation, thus it has the advantage of adapting to the different operating modes

    Physical simulation for monocular 3D model based tracking

    Get PDF
    The problem of model-based object tracking in three dimensions is addressed. Most previous work on tracking assumes simple motion models, and consequently tracking typically fails in a variety of situations. Our insight is that incorporating physics models of object behaviour improves tracking performance in these cases. In particular it allows us to handle tracking in the face of rigid body interactions where there is also occlusion and fast object motion. We show how to incorporate rigid body physics simulation into a particle filter. We present two methods for this based on pose and force noise. The improvements are tested on four videos of a robot pushing an object, and results indicate that our approach performs considerably better than a plain particle filter tracker, with the force noise method producing the best results over the range of test videos

    Supporting Collaborative Health Tracking in the Hospital: Patients' Perspectives

    Get PDF
    The hospital setting creates a high-stakes environment where patients' lives depend on accurate tracking of health data. Despite recent work emphasizing the importance of patients' engagement in their own health care, less is known about how patients track their health and care in the hospital. Through interviews and design probes, we investigated hospitalized patients' tracking activity and analyzed our results using the stage-based personal informatics model. We used this model to understand how to support the tracking needs of hospitalized patients at each stage. In this paper, we discuss hospitalized patients' needs for collaboratively tracking their health with their care team. We suggest future extensions of the stage-based model to accommodate collaborative tracking situations, such as hospitals, where data is collected, analyzed, and acted on by multiple people. Our findings uncover new directions for HCI research and highlight ways to support patients in tracking their care and improving patient safety

    AAA gunnermodel based on observer theory

    Get PDF
    The Luenberger observer theory is used to develop a predictive model of a gunner's tracking response in antiaircraft artillery systems. This model is composed of an observer, a feedback controller and a remnant element. An important feature of the model is that the structure is simple, hence a computer simulation requires only a short execution time. A parameter identification program based on the least squares curve fitting method and the Gauss Newton gradient algorithm is developed to determine the parameter values of the gunner model. Thus, a systematic procedure exists for identifying model parameters for a given antiaircraft tracking task. Model predictions of tracking errors are compared with human tracking data obtained from manned simulation experiments. Model predictions are in excellent agreement with the empirical data for several flyby and maneuvering target trajectories

    Error rate information in attention allocation pilot models

    Get PDF
    The Northrop urgency decision pilot model was used in a command tracking task to compare the optimized performance of multiaxis attention allocation pilot models whose urgency functions were (1) based on tracking error alone, and (2) based on both tracking error and error rate. A matrix of system dynamics and command inputs was employed, to create both symmetric and asymmetric two axis compensatory tracking tasks. All tasks were single loop on each axis. Analysis showed that a model that allocates control attention through nonlinear urgency functions using only error information could not achieve performance of the full model whose attention shifting algorithm included both error and error rate terms. Subsequent to this analysis, tracking performance predictions for the full model were verified by piloted flight simulation. Complete model and simulation data are presented
    • …
    corecore