34,963 research outputs found

    A design for testability study on a high performance automatic gain control circuit.

    Get PDF
    A comprehensive testability study on a commercial automatic gain control circuit is presented which aims to identify design for testability (DfT) modifications to both reduce production test cost and improve test quality. A fault simulation strategy based on layout extracted faults has been used to support the study. The paper proposes a number of DfT modifications at the layout, schematic and system levels together with testability. Guidelines that may well have generic applicability. Proposals for using the modifications to achieve partial self test are made and estimates of achieved fault coverage and quality levels presente

    Oscillation-Based Test Structure and Method for OTA-C Filters

    Get PDF
    “This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder." “Copyright IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE.”This paper describes a design for testability technique for operational transconductance amplifier and capacitor filters using an oscillation-based test topology. The oscillation-based test structure is a vectorless output test strategy easily extendable to built-in self-test. The proposed methodology converts filter under test into a quadrature oscillator using very simple techniques and measures the output frequency. The oscillation frequency may be considered as a digital signal and it can be evaluated using digital circuitry therefore the test time is very small. These characteristics imply that the proposed method is very suitable for catastrophic and parametric faults testing and also effective in detecting single and multiple faults. The validity of the proposed method has been verified using comparison between faulty and fault-free simulation results of two integrator loop and Tow-Thomas filters. Simulation results in 0.25 mum CMOS technology show that the proposed oscillation-based test strategy for OTA-C filters has 87% fault coverage and with a minimum number of extra components, requires a negligible area overhead

    Design for testability of high-order OTA-C filters

    Get PDF
    Copyright © 2016 John Wiley & Sons, Ltd.A study of oscillation-based test for high-order Operational Transconductance Amplifier-C (OTA-C) filters is presented. The method is based on partition of a high-order filter into second-order filter functions. The opening Q-loop and adding positive feedback techniques are developed to convert the second-order filter section into a quadrature oscillator. These techniques are based on an open-loop configuration and an additional positive feedback configuration. Implementation of the two testability design methods for nth-order cascade, IFLF and leapfrog (LF) filters is presented, and the area overhead of the modified circuits is also discussed. The performances of the presented techniques are investigated. Fourth-order cascade, inverse follow-the-leader feedback (IFLF) and LF OTA-C filters were designed and simulated for analysis of fault coverage using the adding positive feedback method based on an analogue multiplexer. Simulation results show that the oscillation-based test method using positive feedback provides high fault coverage of around 97%, 96% and 95% for the cascade, IFLF and LF OTA-C filters, respectively. Copyright ÂPeer reviewe

    Oscillation-based DFT for Second-order Bandpass OTA-C Filters

    Get PDF
    This document is the Accepted Manuscript version. Under embargo until 6 September 2018. The final publication is available at Springer via https://doi.org/10.1007/s00034-017-0648-9.This paper describes a design for testability technique for second-order bandpass operational transconductance amplifier and capacitor filters using an oscillation-based test topology. The oscillation-based test structure is a vectorless output test strategy easily extendable to built-in self-test. The proposed methodology converts filter under test into a quadrature oscillator using very simple techniques and measures the output frequency. Using feedback loops with nonlinear block, the filter-to-oscillator conversion techniques easily convert the bandpass OTA-C filter into an oscillator. With a minimum number of extra components, the proposed scheme requires a negligible area overhead. The validity of the proposed method has been verified using comparison between faulty and fault-free simulation results of Tow-Thomas and KHN OTA-C filters. Simulation results in 0.25Îźm CMOS technology show that the proposed oscillation-based test strategy for OTA-C filters is suitable for catastrophic and parametric faults testing and also effective in detecting single and multiple faults with high fault coverage.Peer reviewedFinal Accepted Versio

    Optimization of Battery Energy Storage to Improve Power System Oscillation Damping

    Full text link
    A placement problem for multiple Battery Energy Storage System (BESS) units is formulated towards power system transient voltage stability enhancement in this paper. The problem is solved by the Cross-Entropy (CE) optimization method. A simulation-based approach is adopted to incorporate higher-order dynamics and nonlinearities of generators and loads. The objective is to maximize the voltage stability index, which is setup based on certain grid-codes. Formulations of the optimization problem are then discussed. Finally, the proposed approach is implemented in MATLAB/DIgSILENT and tested on the New England 39-Bus system. Results indicate that installing BESS units at the optimized location can alleviate transient voltage instability issue compared with the original system with no BESS. The CE placement algorithm is also compared with the classic PSO (Particle Swarm Optimization) method, and its superiority is demonstrated in terms of a faster convergence rate with matched solution qualities.Comment: This paper has been accepted by IEEE Transactions on Sustainable Energy and now still in online-publication phase, IEEE Transactions on Sustainable Energy. 201

    A recursive-faulting model of distributed damage in confined brittle materials

    Get PDF
    We develop a model of distributed damage in brittle materials deforming in triaxial compression based on the explicit construction of special microstructures obtained by recursive faulting. The model aims to predict the effective or macroscopic behavior of the material from its elastic and fracture properties; and to predict the microstructures underlying the microscopic behavior. The model accounts for the elasticity of the matrix, fault nucleation and the cohesive and frictional behavior of the faults. We analyze the resulting quasistatic boundary value problem and determine the relaxation of the potential energy, which describes the macroscopic material behavior averaged over all possible fine-scale structures. Finally, we present numerical calculations of the dynamic multi-axial compression experiments on sintered aluminum nitride of Chen and Ravichandran [1994. Dynamic compressive behavior of ceramics under lateral confinement. J. Phys. IV 4, 177–182; 1996a. Static and dynamic compressive behavior of aluminum nitride under moderate confinement. J. Am. Soc. Ceramics 79(3), 579–584; 1996b. An experimental technique for imposing dynamic multiaxial compression with mechanical confinement. Exp. Mech. 36(2), 155–158; 2000. Failure mode transition in ceramics under dynamic multiaxial compression. Int. J. Fracture 101, 141–159]. The model correctly predicts the general trends regarding the observed damage patterns; and the brittle-to-ductile transition resulting under increasing confinement

    Time domain analysis of partial discharges envelope in medium voltage XLPE cables

    Get PDF
    Partial discharge (PD) analysis has been widely used to detect premature degradation of power cables. Although there are recognized techniques for PD analysis, there is still lack of knowledge about measuring and modeling this phenomenon. This paper proposes a new model based on time domain parameters of the PD signal envelope. The proposed variables (time duration, and rising and falling slopes of the envelopes), together with conventional PD analyses focused on PD amplitude and phase resolved patterns, will provide a better understanding of this phenomenon. Based on this model, a new technique to reshape the PD signal envelope is also proposed that compensates the negative effect of dispersion in the location techniques that estimate the time of arrival (TOA). Experimental results were obtained in the lab, where a power cable has been artificially damaged in order to produce PD. To this end, a specific PD on-line acquisition system has been developed. In the first set of experiments, we illustrate how the cable attenuates and disperses the PD signal envelope. In the second one, we show how the proposed variables are useful to distinguish among different types of PD sources. Finally, an accurate estimation of the PD source location is achieved by measuring the time of arrival of the PD signal envelopes at both cable ends, and reshaping one of the signals captured. This technique improves the accuracy of the estimated location of the PD sources, both in simulation and in experimental results
    • …
    corecore