1,647 research outputs found

    Custom Cell Placement Automation for Asynchronous VLSI

    Get PDF
    Asynchronous Very-Large-Scale-Integration (VLSI) integrated circuits have demonstrated many advantages over their synchronous counterparts, including low power consumption, elastic pipelining, robustness against manufacturing and temperature variations, etc. However, the lack of dedicated electronic design automation (EDA) tools, especially physical layout automation tools, largely limits the adoption of asynchronous circuits. Existing commercial placement tools are optimized for synchronous circuits, and require a standard cell library provided by semiconductor foundries to complete the physical design. The physical layouts of cells in this library have the same height to simplify the placement problem and the power distribution network. Although the standard cell methodology also works for asynchronous designs, the performance is inferior compared with counterparts designed using the full-custom design methodology. To tackle this challenge, we propose a gridded cell layout methodology for asynchronous circuits, in which the cell height and cell width can be any integer multiple of two grid values. The gridded cell approach combines the shape regularity of standard cells with the size flexibility of full-custom layouts. Therefore, this approach can achieve a better space utilization ratio and lower wire length for asynchronous designs. Experiments have shown that the gridded cell placement approach reduces area without impacting the routability. We have also used this placer to tape out a chip in a 65nm process technology, demonstrating that our placer generates design-rule clean results

    Development, Optimization and Clinical Evaluation Of Algorithms For Ultrasound Data Analysis Used In Selected Medical Applications.

    Get PDF
    The assessment of soft and hard tissues is critical when selecting appropriate protocols for restorative and regenerative therapy in the field of dental surgery. The chosen treatment methodology will have significant ramifications on healing time, success rate and overall long-time oral health. Currently used diagnostic methods are limited to visual and invasive assessments; they are often user-dependent, inaccurate and result in misinterpretation. As such, the clinical need has been identified for objective tissue characterization, and the proposed novel ultrasound-based approach was designed to address the identified need. The device prototype consists of a miniaturized probe with a specifically designed ultrasonic transducer, electronics responsible for signal generation and acquisition, as well as an optimized signal processing algorithm required for data analysis. An algorithm where signals are being processed and features extracted in real-time has been implemented and studied. An in-depth algorithm performance study has been presented on synthetic signals. Further, in-vitro laboratory experiments were performed using the developed device with the algorithm implemented in software on animal-based samples. Results validated the capabilities of the new system to reproduce gingival assessment rapidly and effectively. The developed device has met clinical usability requirements for effectiveness and performance

    X-Ray Microtags for the Detection of Post-Operative Foreign Objects

    Full text link
    Dr. Theodore Marentis Professor Nikolaos Chronishttp://deepblue.lib.umich.edu/bitstream/2027.42/96181/1/me450f12project4_report.pd

    ポータビリティを意識したCMOSミックスドシグナルVLSI回路設計手法に関する研究

    Get PDF
    本研究は、半導体上に集積されたアナログ・ディジタル・メモリ回路から構成されるミクストシグナルシステムを別の製造プロセスへ移行することをポーティングとして定義し、効率的なポーティングを行うための設計方式と自動回路合成アルゴリズムを提案し、いくつかの典型的な回路に対する設計事例を示し、提案手法の妥当性を立証している。北九州市立大

    A novel deep submicron bulk planar sizing strategy for low energy subthreshold standard cell libraries

    Get PDF
    Engineering andPhysical Science ResearchCouncil (EPSRC) and Arm Ltd for providing funding in the form of grants and studentshipsThis work investigates bulk planar deep submicron semiconductor physics in an attempt to improve standard cell libraries aimed at operation in the subthreshold regime and in Ultra Wide Dynamic Voltage Scaling schemes. The current state of research in the field is examined, with particular emphasis on how subthreshold physical effects degrade robustness, variability and performance. How prevalent these physical effects are in a commercial 65nm library is then investigated by extensive modeling of a BSIM4.5 compact model. Three distinct sizing strategies emerge, cells of each strategy are laid out and post-layout parasitically extracted models simulated to determine the advantages/disadvantages of each. Full custom ring oscillators are designed and manufactured. Measured results reveal a close correlation with the simulated results, with frequency improvements of up to 2.75X/2.43X obs erved for RVT/LVT devices respectively. The experiment provides the first silicon evidence of the improvement capability of the Inverse Narrow Width Effect over a wide supply voltage range, as well as a mechanism of additional temperature stability in the subthreshold regime. A novel sizing strategy is proposed and pursued to determine whether it is able to produce a superior complex circuit design using a commercial digital synthesis flow. Two 128 bit AES cores are synthesized from the novel sizing strategy and compared against a third AES core synthesized from a state-of-the-art subthreshold standard cell library used by ARM. Results show improvements in energy-per-cycle of up to 27.3% and frequency improvements of up to 10.25X. The novel subthreshold sizing strategy proves superior over a temperature range of 0 °C to 85 °C with a nominal (20 °C) improvement in energy-per-cycle of 24% and frequency improvement of 8.65X. A comparison to prior art is then performed. Valid cases are presented where the proposed sizing strategy would be a candidate to produce superior subthreshold circuits

    Active surgical positioning device for a cochlear implant electrode array

    Get PDF
    Cochlear implants have been of great benefit in restoring auditory function to individuals with profound bilateral sensorineural deafness. The implants are used to directly stimulate auditory nerves and send a signal to the brain that is then interpreted as sound. This project focuses on the development of a surgical positioning tool to accurately and effectively place an array of stimulating electrodes deep within the cochlea. This will lead to improved efficiency and performance of the stimulating electrodes, reduced surgical trauma to the cochlea, and as a result, improved overall performance to the implant recipient. The positioning tool reported here consists of multiple fluidic chambers providing localized curvature control along the length of the attached silicon electrode array. The chambers consist of 200μm inner diameter PET (polyethylene therephthalate) tubes with 4μm wall thickness. The chambers are molded in a tapered helical configuration to correspond to the cochlear shape upon relaxation of the actuators. This ensures that the optimal electrode placement within the cochlea is retained after the positioning tool becomes dormant (for chronic implants). Actuation is achieved by injecting fluid into the PET chambers and regulating the fluidic pressure. The chambers are arranged in a stacked, overlapping design to provide fluid connectivity with the non-implantable pressure controller and allow for local curvature control of the device. The stacked tube configuration allows for localized curvature control of various areas along the length of the electrode and additional stiffening and actuating power towards the base. Curvature is affected along the entire length of a chamber and the result is cumulative in sections of multiple chambers. The actuating chambers are bonded to the back of a silicon electrode array

    Design of LCOS microdisplay backplanes for projection applications

    Get PDF
    De evolutie van licht emitterende diodes (LED) heeft ervoor gezorgd dat het op dit moment interessant wordt om deze componenten als lichtbron te gebruiken in projectiesystemen. LED’s hebben belangrijke voordelen vergeleken met klassieke booglampen. Ze zijn compact, ze hebben een veel grotere levensduur en ogenblikkelijke schakeltijden, ze werken op lage spanningen, etc. LED’s zijn smalbandig en kunnen een groterekleurenbereik realiseren. Ze hebben momenteel echter een beperkte helderheid. Naast de lichtbron is het type van de lichtklep ook bepalend voor de kwaliteit van een projectiesysteem. Er bestaan verschillende lichtkleptechnologieën waaronder die van de reflectieve LCOS-panelen. Deze lichtkleppen kunnen zeer hoge resoluties hebben en wordenvaak gebruikt in kwalitatieve, professionele projectiesystemen. LED’s zijn echter totaal verschillend van booglampen. Ze hebben een andere vorm, package, stralingspatroon, aansturing, fysische en thermische eigenschappen, etc. Hoewel er een twintigtal optische architecturen bekend zijn voor reflectieve beeldschermen (met een booglamp als lichtbron), zijn ze niet geschikt voor LED-projectoren en moeten nieuwe optische architecturen en een elektronische aansturing ontwikkeld worden. In dit doctoraat werd er hieromtrent onderzoek gedaan. Er werd uiteindelijk een driekleurenprojector (R, G, B) met een efficiënt LED-belichtingssysteem gebouwd met twee LCOS-lichtkleppen. Deze LEDprojector heeft superieure eigenschappen (zeer lange levensduur, beeldkwaliteit, etc.) en een matige lichtopbrengst

    Safety of Simultaneous Scalp and Intracranial Electroencephalography Functional Magnetic Resonance Imaging

    Get PDF
    Understanding the brain and its activity is one of the great challenges of modern science. Normal brain activity (cognitive processes, etc.) has been extensively studied using electroencephalography (EEG) since the 1930’s, in the form of spontaneous fluctuations in rhythms, and patterns, and in a more experimentally-driven approach in the form of event-related potentials allowing us to relate scalp voltage waveforms to brain states and behaviour. The use of EEG recorded during functional magnetic resonance imaging (EEG-fMRI) is a more recent development that has become an important tool in clinical neuroscience, for example, for the study of epileptic activity. The primary aim of this thesis is to devise a protocol in order to minimise the health risks that are associated with simultaneous scalp and intracranial EEG during fMRI (S- icEEG-fMRI). The advances in this technique will be helpful in presenting a new imaging method that will allow the measurement of brain activity with unprecedented sensitivity and coverage. However, this cannot be achieved without assessing the safety implications of such a technique. Therefore, five experiments were performed to fulfil the primary aim. First, the safety of icEEG- fMRI using body transmit RF coil was investigated to improve the results of previous attempts using a head transmit coil at 1.5T. The results of heating increases during a high-SAR sequence were in the range of 0.2-2.4 °C at the contacts with leads positioned along the central axis inside the MRI bore. These findings suggest the need for careful lead placement. Second, also for the body transmit coil we compared the heating in the vicinity of icEEG electrodes placed inside a realistically-shaped head phantom following the addition of scalp EEG electrodes. The peak temperature change was +2.7 °C at the most superior icEEG electrode contact without scalp electrodes, and +2.1 °C at the same contact and the peak increase in the vicinity of a scalp electrode contact was +0.6 °C (location FP2). These findings show that the S-icEEG-fMRI technique is feasible if our protocol is followed carefully. Third, the heating of a realistic 3D model of icEEG electrode during MRI using EM computational simulation was investigated. The resulting peak 10 g averaged SAR was 20% higher than without icEEG. Moreover, the superior icEEG placed perpendicular to B0 showed significant local SAR increase. These results were in line with previous studies. Fourth, the possibility of simplifying a complete 8-contact with 8 wires depth icEEG electrode model into an electrode with 1-contact and 1 wire using EM simulations was addressed. The results showed similar patterns of averaged SAR values around the electrode tip during phantom and electrode position along Z for the Complete and Simplified models, except an average maximum at Z = ~2.5 W/kg for the former. The SAR values during insertion depth for the Simplified model were double those for the Complete model. The effect of extension cable length is in agreement with previous experiments. Fifth, further simulations were implemented using two more simplified models: 8-contact with 1 wire shared with all contact and 8-contact 1 wire connected to each contact at a time as well as the previously modelled simplified 1-contact 1 wire. Two sets of simulations were performed: with a single electrode and with multiple electrodes. For the single electrode, three scenarios were tested: the first simplified model used only, the second simplified models used only and the third model positioned in different 13 locations. The results of these simulations showed about 11.4-20.5-fold lower SAR for the first model than the second and 0.29-5.82-fold lower SAR for the first model than the complete model. The results also showed increased SAR for the electrode close to the head coil than the ones away from it. For the multiple electrodes, three scenarios were tested: two 1-contact and wire electrodes in different separations, multiple electrodes with their wires separated and multiple electrodes with their wires shorted. The results showed interaction between the two tested electrodes. The results of the multiple electrodes presented 2 to ~10 times higher SAR for the separated setup than the shorted. The comparison between the 1-contact with 1 wire model and the complete model is still unknown and more tests are required to show it. From the findings of this PhD research, we conclude that a body RF coil can be utilized for icEEG-fMRI at 1.5 T; however, the safety protocol has to be implemented. In addition, scalp EEG can be used in conjunction with icEEG electrodes inside the body RF coil at 1.5 T and the safety protocol has to be followed. Finally, it is feasible to perform EM computational simulations using realistic icEEG electrodes on a human model. However, simplifying the realistic icEEG electrode model might result in overestimations of the heating, although it is possible that the simplification of the model can help to simulate more complex implantations such as the implantation of multiple electrodes with their leads open circuited or short circuited, which can provide more information about the safety of implanted patients inside the MRI
    corecore