278 research outputs found
Computer-aided detection and diagnosis of breast cancer in 2D and 3D medical imaging through multifractal analysis
This Thesis describes the research work performed in the scope of a doctoral research program
and presents its conclusions and contributions. The research activities were carried on in the
industry with Siemens S.A. Healthcare Sector, in integration with a research team.
Siemens S.A. Healthcare Sector is one of the world biggest suppliers of products, services and
complete solutions in the medical sector. The company offers a wide selection of diagnostic
and therapeutic equipment and information systems. Siemens products for medical imaging and
in vivo diagnostics include: ultrasound, computer tomography, mammography, digital breast tomosynthesis,
magnetic resonance, equipment to angiography and coronary angiography, nuclear
imaging, and many others.
Siemens has a vast experience in Healthcare and at the beginning of this project it was strategically
interested in solutions to improve the detection of Breast Cancer, to increase its competitiveness
in the sector.
The company owns several patents related with self-similarity analysis, which formed the background
of this Thesis. Furthermore, Siemens intended to explore commercially the computer-
aided automatic detection and diagnosis eld for portfolio integration. Therefore, with the
high knowledge acquired by University of Beira Interior in this area together with this Thesis,
will allow Siemens to apply the most recent scienti c progress in the detection of the breast
cancer, and it is foreseeable that together we can develop a new technology with high potential.
The project resulted in the submission of two invention disclosures for evaluation in Siemens
A.G., two articles published in peer-reviewed journals indexed in ISI Science Citation Index,
two other articles submitted in peer-reviewed journals, and several international conference
papers. This work on computer-aided-diagnosis in breast led to innovative software and novel
processes of research and development, for which the project received the Siemens Innovation
Award in 2012.
It was very rewarding to carry on such technological and innovative project in a socially sensitive
area as Breast Cancer.No cancro da mama a deteção precoce e o diagnóstico correto são de extrema importância na
prescrição terapêutica e caz e e ciente, que potencie o aumento da taxa de sobrevivência Ã
doença. A teoria multifractal foi inicialmente introduzida no contexto da análise de sinal e a
sua utilidade foi demonstrada na descrição de comportamentos siológicos de bio-sinais e até
na deteção e predição de patologias. Nesta Tese, três métodos multifractais foram estendidos
para imagens bi-dimensionais (2D) e comparados na deteção de microcalci cações em mamogramas.
Um destes métodos foi também adaptado para a classi cação de massas da mama, em
cortes transversais 2D obtidos por ressonância magnética (RM) de mama, em grupos de massas
provavelmente benignas e com suspeição de malignidade. Um novo método de análise multifractal
usando a lacunaridade tri-dimensional (3D) foi proposto para classi cação de massas da
mama em imagens volumétricas 3D de RM de mama. A análise multifractal revelou diferenças
na complexidade subjacente às localizações das microcalci cações em relação aos tecidos normais,
permitindo uma boa exatidão da sua deteção em mamogramas. Adicionalmente, foram
extraÃdas por análise multifractal caracterÃsticas dos tecidos que permitiram identi car os casos
tipicamente recomendados para biópsia em imagens 2D de RM de mama. A análise multifractal
3D foi e caz na classi cação de lesões mamárias benignas e malignas em imagens 3D de RM de
mama. Este método foi mais exato para esta classi cação do que o método 2D ou o método
padrão de análise de contraste cinético tumoral. Em conclusão, a análise multifractal fornece
informação útil para deteção auxiliada por computador em mamogra a e diagnóstico auxiliado
por computador em imagens 2D e 3D de RM de mama, tendo o potencial de complementar a
interpretação dos radiologistas
Improvement for detection of microcalcifications through clustering algorithms and artificial neural networks
A new method for detecting microcalcifications in regions of interest (ROIs) extracted from digitized mammograms is proposed. The top-hat transform is a technique based on mathematical morphology operations and, in this paper, is used to perform contrast enhancement of the mi-crocalcifications. To improve microcalcification detection, a novel image sub-segmentation approach based on the possibilistic fuzzy c-means algorithm is used. From the original ROIs, window-based features, such as the mean and standard deviation, were extracted; these features were used as an input vector in a classifier. The classifier is based on an artificial neural network to identify patterns belonging to microcalcifications and healthy tissue. Our results show that the proposed method is a good alternative for automatically detecting microcalcifications, because this stage is an important part of early breast cancer detectio
Detecting microcalcification clusters in digital mammograms: Study for inclusion into computer aided diagnostic prompting system
Among signs of breast cancer encountered in digital mammograms radiologists point to microcalcification clusters (MCCs). Their detection is a challenging problem from both medical and image processing point of views. This work presents two concurrent methods for MCC detection, and studies their possible inclusion to a computer aided diagnostic prompting system. One considers Wavelet Domain Hidden Markov Tree (WHMT) for modeling microcalcification edges. The model is used for differentiation between MC and non-MC edges based on the weighted maximum likelihood (WML) values. The classification of objects is carried out using spatial filters. The second method employs SUSAN edge detector in the spatial domain for mammogram segmentation. Classification of objects as calcifications is carried out using another set of spatial filters and Feedforward Neural Network (NN). A same distance filter is employed in both methods to find true clusters. The analysis of two methods is performed on 54 image regions from the mammograms selected randomly from DDSM database, including benign and cancerous cases as well as cases which can be classified as hard cases from both radiologists and the computer perspectives. WHMT/WML is able to detect 98.15% true positive (TP) MCCs under 1.85% of false positives (FP), whereas the SUSAN/NN method achieves 94.44% of TP at the cost of 1.85% for FP. The comparison of these two methods suggests WHMT/WML for the computer aided diagnostic prompting. It also certifies the low false positive rates for both methods, meaning less biopsy tests per patient
A Decision Support System (DSS) for Breast Cancer Detection Based on Invariant Feature Extraction, Classification, and Retrieval of Masses of Mammographic Images
This paper presents an integrated system for the breast cancer detection from mammograms based on automated mass detection, classification, and retrieval with a goal to support decision-making by retrieving and displaying the relevant past cases as well as predicting the images as benign or malignant. It is hypothesized that the proposed diagnostic aid would refresh the radiologist’s mental memory to guide them to a precise diagnosis with concrete visualizations instead of only suggesting a second diagnosis like many other CAD systems. Towards achieving this goal, a Graph-Based Visual Saliency (GBVS) method is used for automatic mass detection, invariant features are extracted based on using Non-Subsampled Contourlet transform (NSCT) and eigenvalues of the Hessian matrix in a histogram of oriented gradients (HOG), and finally classification and retrieval are performed based on using Support Vector Machines (SVM) and Extreme Learning Machines (ELM), and a linear combination-based similarity fusion approach. The image retrieval and classification performances are evaluated and compared in the benchmark Digital Database for Screening Mammography (DDSM) of 2604 cases by using both the precision-recall and classification accuracies. Experimental results demonstrate the effectiveness of the proposed system and show the viability of a real-time clinical application
- …