6,131 research outputs found

    Serial optical coherence microscopy for label-free volumetric histopathology

    Get PDF
    The observation of histopathology using optical microscope is an essential procedure for examination of tissue biopsies or surgically excised specimens in biological and clinical laboratories. However, slide-based microscopic pathology is not suitable for visualizing the large-scale tissue and native 3D organ structure due to its sampling limitation and shallow imaging depth. Here, we demonstrate serial optical coherence microscopy (SOCM) technique that offers label-free, high-throughput, and large-volume imaging of ex vivo mouse organs. A 3D histopathology of whole mouse brain and kidney including blood vessel structure is reconstructed by deep tissue optical imaging in serial sectioning techniques. Our results demonstrate that SOCM has unique advantages as it can visualize both native 3D structures and quantitative regional volume without introduction of any contrast agents

    Three-dimensional histological specimen preparation for accurate imaging and spatial reconstruction of the middle and inner ear

    Get PDF
    PURPOSE:    This paper presents a highly accurate cross-sectional preparation technique. The research aim was to develop an adequate imaging modality for both soft and bony tissue structures featuring high contrast and high resolution. Therefore, the advancement of an already existing microgrinding procedure was pursued. The central objectives were to preserve spatial relations and to ensure the accurate three-dimensional reconstruction of histological sections. METHODS:    Twelve human temporal bone specimens including middle and inner ear structures were utilized. They were embedded in epoxy resin, then dissected by serial grinding and finally digitalized. The actual abrasion of each grinding slice was measured using a tactile length gauge with an accuracy of one micrometre. The cross-sectional images were aligned with the aid of artificial markers and by applying a feature-based, custom-made auto-registration algorithm. To determine the accuracy of the overall reconstruction procedure, a well-known reference object was used for comparison. To ensure the compatibility of the histological data with conventional clinical image data, the image stacks were finally converted into the DICOM standard. RESULTS:    The image fusion of data from temporal bone specimens’ and from non-destructive flat-panel-based volume computed tomography confirmed the spatial accuracy achieved by the procedure, as did the evaluation using the reference object. CONCLUSION:    This systematic and easy-to-follow preparation technique enables the three-dimensional (3D) histological reconstruction of complex soft and bony tissue structures. It facilitates the creation of detailed and spatially correct 3D anatomical models. Such models are of great benefit for image-based segmentation and planning in the field of computer-assisted surgery as well as in finite element analysis. In the context of human inner ear surgery, three-dimensional histology will improve the experimental evaluation and determination of intra-cochlear trauma after the insertion of an electrode array of a cochlear implant system

    Autologous temporomandibular joint reconstruction independent of exogenous additives: a proof-of-concept study for guided self-generation

    Get PDF
    Joint defects are complex and difficult to reconstruct. By exploiting the body's own regenerative capacity, we aimed to individually generate anatomically precise neo-tissue constructs for autologous joint reconstruction without using any exogenous additives. In a goat model, CT scans of the mandibular condyle including articular surface and a large portion of the ascending ramus were processed using computer-aided design and manufacturing. A corresponding hydroxylapatite negative mold was printed in 3D and temporarily embedded into the transition zone of costal periosteum and perichondrium. A demineralized bone matrix scaffold implanted on the contralateral side served as control. Neo-tissue constructs obtained by guided self-generation exhibited accurate configuration, robust vascularization, biomechanical stability, and function. After autologous replacement surgery, the constructs showed stable results with similar anatomical, histological, and functional findings compared to native controls. Further studies are required to assess long-term outcome and possible extensions to other further applications. The absence of exogenous cells, growth factors, and scaffolds may facilitate clinical translation of this approach

    Comparison of extraction sites versus artificial defects with xenogenic bone substitute in minipigs

    Get PDF
    Objectives The preclinical evaluation of bone substitutes is frequently performed in artificially created defects. However, such defects do not reflect the predominant clinical application of bone substitutes for socket preservation. Hence, the goal of this animal study was to compare the performance of a xenogenic bone substitute in extraction sites versus artificial defects. Material and Methods Four study sites each were created in the mandibles of four minipigs in the region of the third premolars and first molars, respectively. On one side, fresh extraction sockets were established while contralaterally trephine defects were created in healed alveolar bone. All sites were augmented using a particulate xenogenic bone substitute, covered by resorbable membranes and allowed to heal for 12 weeks. The amounts of new bone, non-bone tissue and remaining bone substitute granules were quantified through histological and micro-CT analysis. Comparative statistics were based on t-tests for two samples and ANOVA with the level of significance set at α = 0.05. Results Histomorphometric data from only two animals could be quantitatively analyzed due to difficulty with identifying the surgical sites. The percentage of newly formed bone ranged between 53.2% ± 5.6% for artificial defects and 54.9% ± 12.4% for extraction sites. With the exception of ANOVA indicating a greater amount of non-bone tissue in extraction sites as compared to artificial sites (p = 0.047), no statistically significant differences were observed. Micro-CT scans showed patterns similar to the ones observed in histomorphometry. As extraction sites could be identified only in two micro-CT reconstructions, quantitative assessment was not undertaken. Conclusions Despite the comparable performance of bone substitute material in artificial defects and extraction sites found here, the data gathered with this experiment was insufficient for showing equivalence of both approaches

    Current Approaches for Image Fusion of Histological Data with Computed Tomography and Magnetic Resonance Imaging

    Get PDF
    Classical analysis of biological samples requires the destruction of the tissue’s integrity by cutting or grinding it down to thin slices for (Immuno)-histochemical staining and microscopic analysis. Despite high specificity, encoded in the stained 2D section of the whole tissue, the structural information, especially 3D information, is limited. Computed tomography (CT) or magnetic resonance imaging (MRI) scans performed prior to sectioning in combination with image registration algorithms provide an opportunity to regain access to morphological characteristics as well as to relate histological findings to the 3D structure of the local tissue environment. This review provides a summary of prevalent literature addressing the problem of multimodal coregistration of hard- and soft-tissue in microscopy and tomography. Grouped according to the complexity of the dimensions, including image-to-volume (2D ⟶ 3D), image-to-image (2D ⟶ 2D), and volume-to-volume (3D ⟶ 3D), selected currently applied approaches are investigated by comparing the method accuracy with respect to the limiting resolution of the tomography. Correlation of multimodal imaging could position itself as a useful tool allowing for precise histological diagnostic and allow the a priori planning of tissue extraction like biopsies

    Comparison of osseointegration in piezoimplants versus cylindrical implants

    Full text link
    BACKGROUND: Dental implants have been successful for the restoration of edentulous areas, but current techniques are inadequate in areas lacking sufficient bone volume. Piezoelectric surgery has shown encouraging effects on both osseous healing. A new wedge-shaped titanium PiezoImplant requires piezoelectric osteotomy. This study compares PiezoImplants to conventional threaded cylindrical shaped implants by microcomputed tomography and histology to assess osseointegration, tissue response, and alveolar ridge changes. METHODS: After 3 months post-extraction, 18 conventional cylindrical implants and 18 wedge-shaped PiezoImplants were placed using a split-mouth design in 3 adult mini pigs. The cylindrical implant sites were prepared for osteotomy with rotary instrumentation while the PiezoImplant sites were prepared with piezoelectric surgical inserts. One animal was sacrificed at 4, 8, and 12 weeks post operation. Quantitative µCT and histological analysis evaluated bone volume, osseointegration, and post-operative cellular events. RESULTS: The results of a multivariable linear regression model demonstrated that the PiezoImplants, arch location, and time were significant factors on higher BV/TV percentage. Bone to implant contact (BIC) analysis by high resolution microscopy and histomorphometry indicated osseointegration though intimate contact between implants and adjacent alveolar bone in both groups. The tissue response displayed no evidence of abnormal healing and the PiezoImplant was classified as a non-irritant. CONCLUSION: The combination of piezoelectric osteotomy and newly designed PiezoImplants had favorable effects on wound healing and osseointegration compared to conventional cylindrical implants. These novel wedge-shaped implants may be beneficial for narrow ridge spaces without additional ridge augmentation. Further research is needed to establish clinical validity
    corecore