Progress in Probe-Based Sensing Techniques for In Vivo Diagnosis
Advancements in robotic surgery help to improve the endoluminal diagnosis and treatment with minimally invasive or non-invasive intervention in a precise and safe manner. Miniaturized probe-based sensors can be used to obtain information about endoluminal anatomy, and they can be integrated with medical robots to augment the convenience of robotic operations. The tremendous benefit of having this physiological information during the intervention has led to the development of a variety of in vivo sensing technologies over the past decades. In this paper, we review the probe-based sensing techniques for the in vivo physical and biochemical sensing in China in recent years, especially on in vivo force sensing, temperature sensing, optical coherence tomography/photoacoustic/ultrasound imaging, chemical sensing, and biomarker sensing
Review of photoacoustic imaging plus X
Photoacoustic imaging (PAI) is a novel modality in biomedical imaging
technology that combines the rich optical contrast with the deep penetration of
ultrasound. To date, PAI technology has found applications in various
biomedical fields. In this review, we present an overview of the emerging
research frontiers on PAI plus other advanced technologies, named as PAI plus
X, which includes but not limited to PAI plus treatment, PAI plus new circuits
design, PAI plus accurate positioning system, PAI plus fast scanning systems,
PAI plus novel ultrasound sensors, PAI plus advanced laser sources, PAI plus
deep learning, and PAI plus other imaging modalities. We will discuss each
technology's current state, technical advantages, and prospects for
application, reported mostly in recent three years. Lastly, we discuss and
summarize the challenges and potential future work in PAI plus X area
Shape sensing of miniature snake-like robots using optical fibers
Snake like continuum robots are increasingly used for minimally invasive surgery. Most robotic devices of this sort that have been reported to date are controlled in an open loop manner. Using shape sensing to provide closed loop feedback would allow for more accurate control of the robot's position and, hence, more precise surgery. Fiber Bragg Gratings, magnetic sensors and optical reflectance sensors have all been reported for this purpose but are often limited by their cost, size, stiffness or complexity of fabrication. To address this issue, we designed, manufactured and tested a prototype two-link robot with a built-in fiber-optic shape sensor that can deliver and control the position of a CO 2 -laser fiber for soft tissue ablation. The shape sensing is based on optical reflectance, and the device (which has a 4 mm outer diameter) is fabricated using 3D printing. Here we present proof-of-concept results demonstrating successful shape sensing - i.e. measurement of the angular displacement of the upper link of the robot relative to the lower link - in real time with a mean measurement error of only 0.7°
A continuum robotic platform for endoscopic non-contact laser surgery: design, control, and preclinical evaluation
The application of laser technologies in surgical interventions has been accepted in the clinical
domain due to their atraumatic properties. In addition to manual application of fibre-guided
lasers with tissue contact, non-contact transoral laser microsurgery (TLM) of laryngeal tumours
has been prevailed in ENT surgery. However, TLM requires many years of surgical training
for tumour resection in order to preserve the function of adjacent organs and thus preserve the
patient’s quality of life. The positioning of the microscopic laser applicator outside the patient
can also impede a direct line-of-sight to the target area due to anatomical variability and limit
the working space. Further clinical challenges include positioning the laser focus on the tissue
surface, imaging, planning and performing laser ablation, and motion of the target area during
surgery. This dissertation aims to address the limitations of TLM through robotic approaches and
intraoperative assistance. Although a trend towards minimally invasive surgery is apparent, no
highly integrated platform for endoscopic delivery of focused laser radiation is available to date.
Likewise, there are no known devices that incorporate scene information from endoscopic imaging
into ablation planning and execution. For focusing of the laser beam close to the target tissue, this
work first presents miniaturised focusing optics that can be integrated into endoscopic systems.
Experimental trials characterise the optical properties and the ablation performance. A robotic
platform is realised for manipulation of the focusing optics. This is based on a variable-length
continuum manipulator. The latter enables movements of the endoscopic end effector in five
degrees of freedom with a mechatronic actuation unit. The kinematic modelling and control of the
robot are integrated into a modular framework that is evaluated experimentally. The manipulation
of focused laser radiation also requires precise adjustment of the focal position on the tissue. For
this purpose, visual, haptic and visual-haptic assistance functions are presented. These support
the operator during teleoperation to set an optimal working distance. Advantages of visual-haptic
assistance are demonstrated in a user study. The system performance and usability of the overall
robotic system are assessed in an additional user study. Analogous to a clinical scenario, the
subjects follow predefined target patterns with a laser spot. The mean positioning accuracy of the
spot is 0.5 mm. Finally, methods of image-guided robot control are introduced to automate laser
ablation. Experiments confirm a positive effect of proposed automation concepts on non-contact
laser surgery.Die Anwendung von Lasertechnologien in chirurgischen Interventionen hat sich aufgrund der atraumatischen Eigenschaften in der Klinik etabliert. Neben manueller Applikation von fasergeführten
Lasern mit Gewebekontakt hat sich die kontaktfreie transorale Lasermikrochirurgie (TLM) von
Tumoren des Larynx in der HNO-Chirurgie durchgesetzt. Die TLM erfordert zur Tumorresektion
jedoch ein langjähriges chirurgisches Training, um die Funktion der angrenzenden Organe zu
sichern und damit die Lebensqualität der Patienten zu erhalten. Die Positionierung des mikroskopis chen Laserapplikators außerhalb des Patienten kann zudem die direkte Sicht auf das Zielgebiet
durch anatomische Variabilität erschweren und den Arbeitsraum einschränken. Weitere klinische
Herausforderungen betreffen die Positionierung des Laserfokus auf der Gewebeoberfläche, die
Bildgebung, die Planung und Ausführung der Laserablation sowie intraoperative Bewegungen
des Zielgebietes. Die vorliegende Dissertation zielt darauf ab, die Limitierungen der TLM durch
robotische Ansätze und intraoperative Assistenz zu adressieren. Obwohl ein Trend zur minimal
invasiven Chirurgie besteht, sind bislang keine hochintegrierten Plattformen für die endoskopische
Applikation fokussierter Laserstrahlung verfügbar. Ebenfalls sind keine Systeme bekannt, die
Szeneninformationen aus der endoskopischen Bildgebung in die Ablationsplanung und -ausführung
einbeziehen. Für eine situsnahe Fokussierung des Laserstrahls wird in dieser Arbeit zunächst
eine miniaturisierte Fokussieroptik zur Integration in endoskopische Systeme vorgestellt. Experimentelle Versuche charakterisieren die optischen Eigenschaften und das Ablationsverhalten. Zur
Manipulation der Fokussieroptik wird eine robotische Plattform realisiert. Diese basiert auf einem
längenveränderlichen Kontinuumsmanipulator. Letzterer ermöglicht in Kombination mit einer
mechatronischen Aktuierungseinheit Bewegungen des Endoskopkopfes in fünf Freiheitsgraden.
Die kinematische Modellierung und Regelung des Systems werden in ein modulares Framework
eingebunden und evaluiert. Die Manipulation fokussierter Laserstrahlung erfordert zudem eine
präzise Anpassung der Fokuslage auf das Gewebe. Dafür werden visuelle, haptische und visuell haptische Assistenzfunktionen eingeführt. Diese unterstützen den Anwender bei Teleoperation
zur Einstellung eines optimalen Arbeitsabstandes. In einer Anwenderstudie werden Vorteile der
visuell-haptischen Assistenz nachgewiesen. Die Systemperformanz und Gebrauchstauglichkeit
des robotischen Gesamtsystems werden in einer weiteren Anwenderstudie untersucht. Analog zu
einem klinischen Einsatz verfolgen die Probanden mit einem Laserspot vorgegebene Sollpfade. Die
mittlere Positioniergenauigkeit des Spots beträgt dabei 0,5 mm. Zur Automatisierung der Ablation
werden abschließend Methoden der bildgestützten Regelung vorgestellt. Experimente bestätigen
einen positiven Effekt der Automationskonzepte für die kontaktfreie Laserchirurgie
Medical Robotics
The first generation of surgical robots are already being installed in a number of operating rooms around the world. Robotics is being introduced to medicine because it allows for unprecedented control and precision of surgical instruments in minimally invasive procedures. So far, robots have been used to position an endoscope, perform gallbladder surgery and correct gastroesophogeal reflux and heartburn. The ultimate goal of the robotic surgery field is to design a robot that can be used to perform closed-chest, beating-heart surgery. The use of robotics in surgery will expand over the next decades without any doubt. Minimally Invasive Surgery (MIS) is a revolutionary approach in surgery. In MIS, the operation is performed with instruments and viewing equipment inserted into the body through small incisions created by the surgeon, in contrast to open surgery with large incisions. This minimizes surgical trauma and damage to healthy tissue, resulting in shorter patient recovery time. The aim of this book is to provide an overview of the state-of-art, to present new ideas, original results and practical experiences in this expanding area. Nevertheless, many chapters in the book concern advanced research on this growing area. The book provides critical analysis of clinical trials, assessment of the benefits and risks of the application of these technologies. This book is certainly a small sample of the research activity on Medical Robotics going on around the globe as you read it, but it surely covers a good deal of what has been done in the field recently, and as such it works as a valuable source for researchers interested in the involved subjects, whether they are currently “medical roboticists” or not
Recommended from our members
A 25 micron-thin microscope for imaging upconverting nanoparticles with NIR-I and NIR-II illumination.
Rationale: Intraoperative visualization in small surgical cavities and hard-to-access areas are essential requirements for modern, minimally invasive surgeries and demand significant miniaturization. However, current optical imagers require multiple hard-to-miniaturize components including lenses, filters and optical fibers. These components restrict both the form-factor and maneuverability of these imagers, and imagers largely remain stand-alone devices with centimeter-scale dimensions. Methods: We have engineered INSITE (Immunotargeted Nanoparticle Single-Chip Imaging Technology), which integrates the unique optical properties of lanthanide-based alloyed upconverting nanoparticles (aUCNPs) with the time-resolved imaging of a 25-micron thin CMOS-based (complementary metal oxide semiconductor) imager. We have synthesized core/shell aUCNPs of different compositions and imaged their visible emission with INSITE under either NIR-I and NIR-II photoexcitation. We characterized aUCNP imaging with INSITE across both varying aUCNP composition and 980 nm and 1550 nm excitation wavelengths. To demonstrate clinical experimental validity, we also conducted an intratumoral injection into LNCaP prostate tumors in a male nude mouse that was subsequently excised and imaged with INSITE. Results: Under the low illumination fluences compatible with live animal imaging, we measure aUCNP radiative lifetimes of 600 μs - 1.3 ms, which provides strong signal for time-resolved INSITE imaging. Core/shell NaEr0.6Yb0.4F4 aUCNPs show the highest INSITE signal when illuminated at either 980 nm or 1550 nm, with signal from NIR-I excitation about an order of magnitude brighter than from NIR-II excitation. The 55 μm spatial resolution achievable with this approach is demonstrated through imaging of aUCNPs in PDMS (polydimethylsiloxane) micro-wells, showing resolution of micrometer-scale targets with single-pixel precision. INSITE imaging of intratumoral NaEr0.8Yb0.2F4 aUCNPs shows a signal-to-background ratio of 9, limited only by photodiode dark current and electronic noise. Conclusion: This work demonstrates INSITE imaging of aUCNPs in tumors, achieving an imaging platform that is thinned to just a 25 μm-thin, planar form-factor, with both NIR-I and NIR-II excitation. Based on a highly paralleled array structure INSITE is scalable, enabling direct coupling with a wide array of surgical and robotic tools for seamless integration with tissue actuation, resection or ablation
Recent advances in biomedical photonic sensors: a focus on optical-fibre-based sensing
In this invited review, we provide an overview of the recent advances in biomedical pho tonic sensors within the last five years. This review is focused on works using optical-fibre technology, employing diverse optical fibres, sensing techniques, and configurations applied in several medical fields. We identified technical innovations and advancements with increased implementations of optical-fibre sensors, multiparameter sensors, and control systems in real applications. Examples of outstanding optical-fibre sensor performances for physical and biochemical parameters are covered, including diverse sensing strategies and fibre-optical probes for integration into medical instruments such as catheters, needles, or endoscopes.This work was supported by Ministerio de Ciencia e Innovación and Agencia Estatal de Investigación (PID2019-107270RB-C21/AEI/10.13039/501100011033), and TeDFeS Project (RTC-2017- 6321-1) co-funded by European FEDER funds. M.O. and J.F.A. received funding from Ministerio de Ciencia, Innovación y Universidades of Spain under Juan de la Cierva-Formación and Juan de la Cierva-Incorporación grants, respectively. P.R-V. received funding from Ministerio de Educación, Cultura y Deporte of Spain under PhD grant FPU2018/02797
Surgical Applications of Compliant Mechanisms:A Review
Current surgical devices are mostly rigid and are made of stiff materials, even though their predominant use is on soft and wet tissues. With the emergence of compliant mechanisms (CMs), surgical tools can be designed to be flexible and made using soft materials. CMs offer many advantages such as monolithic fabrication, high precision, no wear, no friction, and no need for lubrication. It is therefore beneficial to consolidate the developments in this field and point to challenges ahead. With this objective, in this article, we review the application of CMs to surgical interventions. The scope of the review covers five aspects that are important in the development of surgical devices: (i) conceptual design and synthesis, (ii) analysis, (iii) materials, (iv) maim facturing, and (v) actuation. Furthermore, the surgical applications of CMs are assessed by classification into five major groups, namely, (i) grasping and cutting, (ii) reachability and steerability, (iii) transmission, (iv) sensing, and (v) implants and deployable devices. The scope and prospects of surgical devices using CMs are also discussed
ADVANCED IMAGING AND ROBOTICS TECHNOLOGIES FOR MEDICAL APPLICATIONS
Due to the importance of surgery in the medical field, a large amount of research has been conducted in this area. Imaging and robotics technologies provide surgeons with the advanced eye and hand to perform their surgeries in a safer and more accurate manner. Recently medical images have been utilized in the operating room as well as in the diagnostic stage. If the image to patient registration is done with sufficient accuracy, medical images can be used as "a map" for guidance to the target lesion. However, the accuracy and reliability of the surgical navigation system should be sufficiently verified before applying it to the patient. Along with the development of medical imaging, various medical robots have also been developed. In particular, surgical robots have been researched in order to reach the goal of minimal invasiveness. The most important factors to consider are determining the demand, the strategy for their use in operating procedures, and how it aids patients. In addition to the above considerations, medical doctors and researchers should always think from the patient's point of view. In this article, the latest medical imaging and robotic technologies focusing on surgical applications are reviewed based upon the factors described in the above. © 2011 Copyright Taylor and Francis Group, LLC.1
- …