Spatial Filtering Pipeline Evaluation of Cortically Coupled Computer Vision System for Rapid Serial Visual Presentation
Rapid Serial Visual Presentation (RSVP) is a paradigm that supports the
application of cortically coupled computer vision to rapid image search. In
RSVP, images are presented to participants in a rapid serial sequence which can
evoke Event-related Potentials (ERPs) detectable in their Electroencephalogram
(EEG). The contemporary approach to this problem involves supervised spatial
filtering techniques which are applied for the purposes of enhancing the
discriminative information in the EEG data. In this paper we make two primary
contributions to that field: 1) We propose a novel spatial filtering method
which we call the Multiple Time Window LDA Beamformer (MTWLB) method; 2) we
provide a comprehensive comparison of nine spatial filtering pipelines using
three spatial filtering schemes namely, MTWLB, xDAWN, Common Spatial Pattern
(CSP) and three linear classification methods Linear Discriminant Analysis
(LDA), Bayesian Linear Regression (BLR) and Logistic Regression (LR). Three
pipelines without spatial filtering are used as baseline comparison. The Area
Under Curve (AUC) is used as an evaluation metric in this paper. The results
reveal that MTWLB and xDAWN spatial filtering techniques enhance the
classification performance of the pipeline but CSP does not. The results also
support the conclusion that LR can be effective for RSVP based BCI if
discriminative features are available
A new perspective for the training assessment: Machine learning-based neurometric for augmented user's evaluation
Inappropriate training assessment might have either high social costs and economic impacts, especially in high risks categories, such as Pilots, Air Traffic Controllers, or Surgeons. One of the current limitations of the standard training assessment procedures is the lack of information about the amount of cognitive resources requested by the user for the correct execution of the proposed task. In fact, even if the task is accomplished achieving the maximum performance, by the standard training assessment methods, it would not be possible to gather and evaluate information about cognitive resources available for dealing with unexpected events or emergency conditions. Therefore, a metric based on the brain activity (neurometric) able to provide the Instructor such a kind of information should be very important. As a first step in this direction, the Electroencephalogram (EEG) and the performance of 10 participants were collected along a training period of 3 weeks, while learning the execution of a new task. Specific indexes have been estimated from the behavioral and EEG signal to objectively assess the users' training progress. Furthermore, we proposed a neurometric based on a machine learning algorithm to quantify the user's training level within each session by considering the level of task execution, and both the behavioral and cognitive stabilities between consecutive sessions. The results demonstrated that the proposed methodology and neurometric could quantify and track the users' progresses, and provide the Instructor information for a more objective evaluation and better tailoring of training programs. © 2017 Borghini, Aricò, Di Flumeri, Sciaraffa, Colosimo, Herrero, Bezerianos, Thakor and Babiloni
Robust artifactual independent component classification for BCI practitioners
Objective. EEG artifacts of non-neural origin can be separated from neural signals by independent component analysis (ICA). It is unclear (1) how robustly recently proposed artifact classifiers transfer to novel users, novel paradigms or changed electrode setups, and (2) how artifact cleaning by a machine learning classifier impacts the performance of brain–computer interfaces (BCIs). Approach. Addressing (1), the robustness of different strategies with respect to the transfer between paradigms and electrode setups of a recently proposed classifier is investigated on offline data from 35 users and 3 EEG paradigms, which contain 6303 expert-labeled components from two ICA and preprocessing variants. Addressing (2), the effect of artifact removal on single-trial BCI classification is estimated on BCI trials from 101 users and 3 paradigms. Main results. We show that (1) the proposed artifact classifier generalizes to completely different EEG paradigms. To obtain similar results under massively reduced electrode setups, a proposed novel strategy improves artifact classification. Addressing (2), ICA artifact cleaning has little influence on average BCI performance when analyzed by state-of-the-art BCI methods. When slow motor-related features are exploited, performance varies strongly between individuals, as artifacts may obstruct relevant neural activity or are inadvertently used for BCI control. Significance. Robustness of the proposed strategies can be reproduced by EEG practitioners as the method is made available as an EEGLAB plug-in.EC/FP7/224631/EU/Tools for Brain-Computer Interaction/TOBIBMBF, 01GQ0850, Verbundprojekt: Bernstein Fokus Neurotechnologie - Nichtinvasive Neurotechnologie für Mensch-Maschine Interaktion - Teilprojekte A1, A3, A4, B4, W3, ZentrumDFG, 194657344, EXC 1086: BrainLinks-BrainTool
- …