2,415 research outputs found

    Performance of a novel wafer scale CMOS active pixel sensor for bio-medical imaging

    Get PDF
    Recently CMOS Active Pixels Sensors (APSs) have become a valuable alternative to amorphous Silicon and Selenium Flat Panel Imagers (FPIs) in bio-medical imaging applications. CMOS APSs can now be scaled up to the standard 20 cm diameter wafer size by means of a reticle stitching block process. However despite wafer scale CMOS APS being monolithic, sources of non-uniformity of response and regional variations can persist representing a significant challenge for wafer scale sensor response. Non-uniformity of stitched sensors can arise from a number of factors related to the manufacturing process, including variation of amplification, variation between readout components, wafer defects and process variations across the wafer due to manufacturing processes. This paper reports on an investigation into the spatial non-uniformity and regional variations of a wafer scale stitched CMOS APS. For the first time a per-pixel analysis of the electro-optical performance of a wafer CMOS APS is presented, to address inhomogeneity issues arising from the stitching techniques used to manufacture wafer scale sensors. A complete model of the signal generation in the pixel array has been provided and proved capable of accounting for noise and gain variations across the pixel array. This novel analysis leads to readout noise and conversion gain being evaluated at pixel level, stitching block level and in regions of interest, resulting in a coefficient of variation ≤ 1.9%. The uniformity of the image quality performance has been further investigated in a typical X-ray application, i.e. mammography, showing a uniformity in terms of CNR among the highest when compared with mammography detectors commonly used in clinical practise. Finally, in order to compare the detection capability of this novel APS with the currently used technology (i.e. FPIs), theoretical evaluation of the Detection Quantum Efficiency (DQE) at zero-frequency has been performed, resulting in a higher DQE for this detector compared to FPIs. Optical characterization, X-ray contrast measurements and theoretical DQE evaluation suggest that a trade off can be found between the need of a large imaging area and the requirement of a uniform imaging performance, making the DynAMITe large area CMOS APS suitable for a range of bio-medical applications

    Study of spin-scan imaging for outer planets missions

    Get PDF
    The constraints that are imposed on the Outer Planet Missions (OPM) imager design are of critical importance. Imager system modeling analyses define important parameters and systematic means for trade-offs applied to specific Jupiter orbiter missions. Possible image sequence plans for Jupiter missions are discussed in detail. Considered is a series of orbits that allow repeated near encounters with three of the Jovian satellites. The data handling involved in the image processing is discussed, and it is shown that only minimal processing is required for the majority of images for a Jupiter orbiter mission

    Medical system based on thermal optical system and neural network

    Get PDF
    Military personnel in the training or operational phases always need constant medical examination, but the presence of efficient medical care is difficult to implement in real-time for such cases. A wireless system for thermal tracking of soldiers was proposed, as well as tracking their vital signs in real time. Thermal cameras are used with an optical system designed to increase the accuracy of the thermal images captured as the change in the electro-cardiogram, heart rate, and temperature measurements are measured using a specially designed circuit. The results from both the thermal system and the biometric system are combined and sent to a computer for analysis using a model prepared with neural network technology. The proposed system was tested, and a database was created for 127 males and 110 females during training and rest times. The neural network model achieved a response time of 85 seconds until the release of the final analysis, and the accuracy of the proposed tracking system is 96%. The main contribution of this paper is the design of an integrated portable system for rapid, in-field, real-time military medical diagnostics

    Novel image enhancement technique using shunting inhibitory cellular neural networks

    Get PDF
    This paper describes a method for improving image quality in a color CMOS image sensor. The technique simultaneously acts to compress the dynamic range, reorganize the signal to improve visibility, suppress noise, identify local features, achieve color constancy, and lightness rendition. An efficient hardware architecture and a rigorous analysis of the different modules are presented to achieve high quality CMOS digital camera

    NASA Sea Ice Validation Program for the Defense Meteorological Satellite Program Special Sensor Microwave Imager

    Get PDF
    The history of the program is described along with the SSM/I sensor, including its calibration and geolocation correction procedures used by NASA, SSM/I data flow, and the NASA program to distribute polar gridded SSM/I radiances and sea ice concentrations (SIC) on CD-ROMs. Following a discussion of the NASA algorithm used to convert SSM/I radiances to SICs, results of 95 SSM/I-MSS Landsat IC comparisons for regions in both the Arctic and the Antarctic are presented. The Landsat comparisons show that the overall algorithm accuracy under winter conditions is 7 pct. on average with 4 pct. negative bias. Next, high resolution active and passive microwave image mosaics from coordinated NASA and Navy aircraft underflights over regions of the Beaufort and Chukchi seas in March 1988 were used to show that the algorithm multiyear IC accuracy is 11 pct. on average with a positive bias of 12 pct. Ice edge crossings of the Bering Sea by the NASA DC-8 aircraft were used to show that the SSM/I 15 pct. ice concentration contour corresponds best to the location of the initial bands at the ice edge. Finally, a summary of results and recommendations for improving the SIC retrievals from spaceborne radiometers are provided

    Analysis of image noise in multispectral color acquisition

    Get PDF
    The design of a system for multispectral image capture will be influenced by the imaging application, such as image archiving, vision research, illuminant modification or improved (trichromatic) color reproduction. A key aspect of the system performance is the effect of noise, or error, when acquiring multiple color image records and processing of the data. This research provides an analysis that allows the prediction of the image-noise characteristics of systems for the capture of multispectral images. The effects of both detector noise and image processing quantization on the color information are considered, as is the correlation between the errors in the component signals. The above multivariate error-propagation analysis is then applied to an actual prototype system. Sources of image noise in both digital camera and image processing are related to colorimetric errors. Recommendations for detector characteristics and image processing for future systems are then discussed

    CMOS Photodetectors

    Get PDF

    Detection and Characterization of Exoplanets and Disks using Projections on Karhunen-Loeve Eigenimages

    Full text link
    We describe a new method to achieve point spread function (PSF) subtractions for high- contrast imaging using Principal Component Analysis (PCA) that is applicable to both point sources or extended objects (disks). Assuming a library of reference PSFs, a Karhunen-Lo`eve transform of theses references is used to create an orthogonal basis of eigenimages, on which the science target is projected. For detection this approach provides comparable suppression to the Locally Optimized Combination of Images (LOCI) algorithm, albeit with increased robustness to the algorithm parameters and speed enhancement. For characterization of detected sources the method enables forward modeling of astrophysical sources. This alleviates the biases in the astrometry and photometry of discovered faint sources, which are usually associated with LOCI- based PSF subtractions schemes. We illustrate the algorithm performance using archival Hubble Space Telescope (HST) images, but the approach may also be considered for ground-based data acquired with Angular Differential Imaging (ADI) or integral-field spectrographs (IFS).Comment: 12 pages, 4 figure

    The Cosmic Infrared Background Experiment (CIBER): A Sounding Rocket Payload to Study the Near Infrared Extragalactic Background Light

    Get PDF
    The Cosmic Infrared Background Experiment (CIBER) is a suite of four instruments designed to study the near infrared (IR) background light from above the Earth's atmosphere. The instrument package comprises two imaging telescopes designed to characterize spatial anisotropy in the extragalactic IR background caused by cosmological structure during the epoch of reionization, a low resolution spectrometer to measure the absolute spectrum of the extragalactic IR background, and a narrow band spectrometer optimized to measure the absolute brightness of the Zodiacal light foreground. In this paper we describe the design and characterization of the CIBER payload. The detailed mechanical, cryogenic, and electrical design of the system are presented, including all system components common to the four instruments. We present the methods and equipment used to characterize the instruments before and after flight, and give a detailed description of CIBER's flight profile and configurations. CIBER is designed to be recoverable and has flown twice, with modifications to the payload having been informed by analysis of the first flight data. All four instruments performed to specifications during the second flight, and the scientific data from this flight are currently being analyzed
    corecore