20,730 research outputs found

    Dynamic 3D shape measurement based on the phase-shifting moir\'e algorithm

    Full text link
    In order to increase the efficiency of phase retrieval,Wang proposed a high-speed moire phase retrieval method.But it is used only to measure the tiny object. In view of the limitation of Wang method,we proposed a dynamic three-dimensional (3D) measurement based on the phase-shifting moire algorithm.First, four sinusoidal fringe patterns with a pi/2 phase-shift are projected on the reference plane and acquired four deformed fringe patterns of the reference plane in advance. Then only single-shot deformed fringe pattern of the tested object is captured in measurement process.Four moire fringe patterns can be obtained by numerical multiplication between the the AC component of the object pattern and the AC components of the reference patterns respectively. The four low-frequency components corresponding to the moire fringe patterns are calculated by the complex encoding FT (Fourier transform) ,spectrum filtering and inverse FT.Thus the wrapped phase of the object can be determined in the tangent form from the four phase-shifting moire fringe patterns using the four-step phase shifting algorithm.The continuous phase distribution can be obtained by the conventional unwrapping algorithm. Finally, experiments were conducted to prove the validity and feasibility of the proposed method. The results are analyzed and compared with those of Wang method, demonstrating that our method not only can expand the measurement scope, but also can improve accuracy.Comment: 14 pages,5 figures. ams.or

    Optical techniques for 3D surface reconstruction in computer-assisted laparoscopic surgery

    Get PDF
    One of the main challenges for computer-assisted surgery (CAS) is to determine the intra-opera- tive morphology and motion of soft-tissues. This information is prerequisite to the registration of multi-modal patient-specific data for enhancing the surgeon’s navigation capabilites by observ- ing beyond exposed tissue surfaces and for providing intelligent control of robotic-assisted in- struments. In minimally invasive surgery (MIS), optical techniques are an increasingly attractive approach for in vivo 3D reconstruction of the soft-tissue surface geometry. This paper reviews the state-of-the-art methods for optical intra-operative 3D reconstruction in laparoscopic surgery and discusses the technical challenges and future perspectives towards clinical translation. With the recent paradigm shift of surgical practice towards MIS and new developments in 3D opti- cal imaging, this is a timely discussion about technologies that could facilitate complex CAS procedures in dynamic and deformable anatomical regions

    Classically entangled optical beams for high-speed kinematic sensing

    Full text link
    Tracking the kinematics of fast-moving objects is an important diagnostic tool for science and engineering. Existing optical methods include high-speed CCD/CMOS imaging, streak cameras, lidar, serial time-encoded imaging and sequentially timed all-optical mapping. Here, we demonstrate an entirely new approach to positional and directional sensing based on the concept of classical entanglement in vector beams of light. The measurement principle relies on the intrinsic correlations existing in such beams between transverse spatial modes and polarization. The latter can be determined from intensity measurements with only a few fast photodiodes, greatly outperforming the bandwidth of current CCD/CMOS devices. In this way, our setup enables two-dimensional real-time sensing with temporal resolution in the GHz range. We expect the concept to open up new directions in photonics-based metrology and sensing.Comment: v2 includes the real-time measurement from the published version. Reference [29] added. Minor experimental details added on page

    High-resolution ab initio three-dimensional X-ray diffraction microscopy

    Full text link
    Coherent X-ray diffraction microscopy is a method of imaging non-periodic isolated objects at resolutions only limited, in principle, by the largest scattering angles recorded. We demonstrate X-ray diffraction imaging with high resolution in all three dimensions, as determined by a quantitative analysis of the reconstructed volume images. These images are retrieved from the 3D diffraction data using no a priori knowledge about the shape or composition of the object, which has never before been demonstrated on a non-periodic object. We also construct 2D images of thick objects with infinite depth of focus (without loss of transverse spatial resolution). These methods can be used to image biological and materials science samples at high resolution using X-ray undulator radiation, and establishes the techniques to be used in atomic-resolution ultrafast imaging at X-ray free-electron laser sources.Comment: 22 pages, 11 figures, submitte

    Phase Retrieval with Application to Optical Imaging

    Get PDF
    This review article provides a contemporary overview of phase retrieval in optical imaging, linking the relevant optical physics to the information processing methods and algorithms. Its purpose is to describe the current state of the art in this area, identify challenges, and suggest vision and areas where signal processing methods can have a large impact on optical imaging and on the world of imaging at large, with applications in a variety of fields ranging from biology and chemistry to physics and engineering

    On the AER Stereo-Vision Processing: A Spike Approach to Epipolar Matching

    Get PDF
    Image processing in digital computer systems usually considers visual information as a sequence of frames. These frames are from cameras that capture reality for a short period of time. They are renewed and transmitted at a rate of 25-30 fps (typical real-time scenario). Digital video processing has to process each frame in order to detect a feature on the input. In stereo vision, existing algorithms use frames from two digital cameras and process them pixel by pixel until it finds a pattern match in a section of both stereo frames. To process stereo vision information, an image matching process is essential, but it needs very high computational cost. Moreover, as more information is processed, the more time spent by the matching algorithm, the more inefficient it is. Spike-based processing is a relatively new approach that implements processing by manipulating spikes one by one at the time they are transmitted, like a human brain. The mammal nervous system is able to solve much more complex problems, such as visual recognition by manipulating neuron’s spikes. The spike-based philosophy for visual information processing based on the neuro-inspired Address-Event- Representation (AER) is achieving nowadays very high performances. The aim of this work is to study the viability of a matching mechanism in a stereo-vision system, using AER codification. This kind of mechanism has not been done before to an AER system. To do that, epipolar geometry basis applied to AER system are studied, and several tests are run, using recorded data and a computer. The results and an average error are shown (error less than 2 pixels per point); and the viability is proved
    corecore