3,251 research outputs found

    Passive element enriched photoacoustic computed tomography (PER PACT) for simultaneous imaging of acoustic propagation properties and light absorption\ud

    Get PDF
    We present a ‘hybrid’ imaging approach which can image both light absorption properties and acoustic transmission properties of an object in a two-dimensional slice using a computed tomography (CT) photoacoustic imager. The ultrasound transmission measurement method uses a strong optical absorber of small cross-section placed in the path of the light illuminating the sample. This absorber, which we call a passive element acts as a source of ultrasound. The interaction of ultrasound with the sample can be measured in transmission, using the same ultrasound detector used for photoacoustics. Such measurements are made at various angles around the sample in a CT approach. Images of the ultrasound propagation parameters, attenuation and speed of sound, can be reconstructed by inversion of a measurement model. We validate the method on specially designed phantoms and biological specimens. The obtained images are quantitative in terms of the shape, size, location, and acoustic properties of the examined heterogeneitie

    Reconstruction algorithms for multispectral diffraction imaging

    Full text link
    Thesis (Ph.D.)--Boston UniversityIn conventional Computed Tomography (CT) systems, a single X-ray source spectrum is used to radiate an object and the total transmitted intensity is measured to construct the spatial linear attenuation coefficient (LAC) distribution. Such scalar information is adequate for visualization of interior physical structures, but additional dimensions would be useful to characterize the nature of the structures. By imaging using broadband radiation and collecting energy-sensitive measurement information, one can generate images of additional energy-dependent properties that can be used to characterize the nature of specific areas in the object of interest. In this thesis, we explore novel imaging modalities that use broadband sources and energy-sensitive detection to generate images of energy-dependent properties of a region, with the objective of providing high quality information for material component identification. We explore two classes of imaging problems: 1) excitation using broad spectrum sub-millimeter radiation in the Terahertz regime and measure- ment of the diffracted Terahertz (THz) field to construct the spatial distribution of complex refractive index at multiple frequencies; 2) excitation using broad spectrum X-ray sources and measurement of coherent scatter radiation to image the spatial distribution of coherent-scatter form factors. For these modalities, we extend approaches developed for multimodal imaging and propose new reconstruction algorithms that impose regularization structure such as common object boundaries across reconstructed regions at different frequencies. We also explore reconstruction techniques that incorporate prior knowledge in the form of spectral parametrization, sparse representations over redundant dictionaries and explore the advantage and disadvantages of these techniques in terms of image quality and potential for accurate material characterization. We use the proposed reconstruction techniques to explore alternative architectures with reduced scanning time and increased signal-to-noise ratio, including THz diffraction tomography, limited angle X-ray diffraction tomography and the use of coded aperture masks. Numerical experiments and Monte Carlo simulations were conducted to compare performances of the developed methods, and validate the studied architectures as viable options for imaging of energy-dependent properties

    Resolution Study of a Hyperspectral Sensor Using Computed Tomography in the Process of Noise

    Get PDF
    Recently, a new type of hyperspectral imaging sensor has been proposed which simultaneously records both spectral data and multiple spatial dimensions. Unlike dispersive imaging spectrometers, chromo-tomographic hyperspectral imaging sensors (CTHIS) record two spatial dimensions as well as a spectral dimension using computed tomography (CT) techniques with only a finite number of spatially-spectrally diverse images. To date, the factors affecting resolution of these sensors have not been examined. This research examines factors affecting resolution, specifically the number of the focus planes needed to resolve a particular object calculated from a theoretical lower bound, determine a method of reconstructing a hyperspectral object in the presence of noise and background and verify the proposed method of reconstruction and the lower bound applying the proposed reconstruction method to laboratory data. Finally, a simple method is proposed and tested to use this sensor in the presence of atmospheric turbulence with a modified reconstructor to blindly estimate the seeing parameter

    Device-free Localization using Received Signal Strength Measurements in Radio Frequency Network

    Full text link
    Device-free localization (DFL) based on the received signal strength (RSS) measurements of radio frequency (RF)links is the method using RSS variation due to the presence of the target to localize the target without attaching any device. The majority of DFL methods utilize the fact the link will experience great attenuation when obstructed. Thus that localization accuracy depends on the model which describes the relationship between RSS loss caused by obstruction and the position of the target. The existing models is too rough to explain some phenomenon observed in the experiment measurements. In this paper, we propose a new model based on diffraction theory in which the target is modeled as a cylinder instead of a point mass. The proposed model can will greatly fits the experiment measurements and well explain the cases like link crossing and walking along the link line. Because the measurement model is nonlinear, particle filtering tracing is used to recursively give the approximate Bayesian estimation of the position. The posterior Cramer-Rao lower bound (PCRLB) of proposed tracking method is also derived. The results of field experiments with 8 radio sensors and a monitored area of 3.5m 3.5m show that the tracking error of proposed model is improved by at least 36 percent in the single target case and 25 percent in the two targets case compared to other models.Comment: This paper has been withdrawn by the author due to some mistake

    Physics-assisted Generative Adversarial Network for X-Ray Tomography

    Full text link
    X-ray tomography is capable of imaging the interior of objects in three dimensions non-invasively, with applications in biomedical imaging, materials science, electronic inspection, and other fields. The reconstruction process can be an ill-conditioned inverse problem, requiring regularization to obtain satisfactory reconstructions. Recently, deep learning has been adopted for tomographic reconstruction. Unlike iterative algorithms which require a distribution that is known a priori, deep reconstruction networks can learn a prior distribution through sampling the training distributions. In this work, we develop a Physics-assisted Generative Adversarial Network (PGAN), a two-step algorithm for tomographic reconstruction. In contrast to previous efforts, our PGAN utilizes maximum-likelihood estimates derived from the measurements to regularize the reconstruction with both known physics and the learned prior. Synthetic objects with spatial correlations are integrated circuits (IC) from a proposed model CircuitFaker. Compared with maximum-likelihood estimation, PGAN can reduce the photon requirement with limited projection angles to achieve a given error rate. We further attribute the improvement to the learned prior by reconstructing objects created without spatial correlations. The advantages of using a prior from deep learning in X-ray tomography may further enable low-photon nanoscale imaging.Comment: arXiv admin note: text overlap with arXiv:2111.0801

    Lensless wide-field fluorescent imaging on a chip using compressive decoding of sparse objects.

    Get PDF
    We demonstrate the use of a compressive sampling algorithm for on-chip fluorescent imaging of sparse objects over an ultra-large field-of-view (>8 cm(2)) without the need for any lenses or mechanical scanning. In this lensfree imaging technique, fluorescent samples placed on a chip are excited through a prism interface, where the pump light is filtered out by total internal reflection after exciting the entire sample volume. The emitted fluorescent light from the specimen is collected through an on-chip fiber-optic faceplate and is delivered to a wide field-of-view opto-electronic sensor array for lensless recording of fluorescent spots corresponding to the samples. A compressive sampling based optimization algorithm is then used to rapidly reconstruct the sparse distribution of fluorescent sources to achieve approximately 10 microm spatial resolution over the entire active region of the sensor-array, i.e., over an imaging field-of-view of >8 cm(2). Such a wide-field lensless fluorescent imaging platform could especially be significant for high-throughput imaging cytometry, rare cell analysis, as well as for micro-array research

    Compact multi-aperture imaging with high-angular-resolution

    Get PDF
    Previous reports have demonstrated that it is possible to emulate the imaging function of a single conventional lens with an NxN array of identical lenslets to provide an N-fold reduction in imaging-system track length. This approach limits the application to low-resolution imaging. We highlight how using an array of dissimilar lenslets, with an array width that can be much wider than the detector array, high-resolution super-resolved imaging is possible. We illustrate this approach with a ray-traced design and optimization of a long-wave infrared system employing a 3x3 array of free-form lenslets to provide a four-fold reduction in track length compared to a baseline system. Simulations of image recovery show that recovered image quality is comparable to that of the baseline system
    • …
    corecore