12 research outputs found
Design and Control of a Robotic Forceps Manipulator with Screw-Drive Bending Mechanism and Extension of Its Motion Space
AbstractIn this paper, a multi-DOF robotic forceps manipulator that was developed in our laboratory is reviewed. We have developed a new bending technique with a screwdrive mechanism so far, which allows for omnidirectional bending motion by rotating two linkages. The screwdrive mechanism, termed double-screw-drive (DSD) mechanism, was utilized in a multi-DOF robotic forceps manipulator for laparoscopic surgery. Control of a robotic forceps manipulator incorporating the DSD mechanism (DSD forceps) through a teleoperation system was attempted via a joystick-type manipulator. For the teleoperation system, a Lyapunov function based bilateral control law that is capable of motion scaling in both position and force tracking was proposed so as to guarantee stability of the teleoperation system in the presence of time-varying delay. Then, the proposed bilateral control law was adopted for omnidirectional bending of the DSD forceps. Thus, a scalable surgical device that can provide force feedback to surgeon via a joystick-type manipulator was achieved. In addition, to extend the motion space of the DSD mechanism, design of the former DSD mechanism was improved so that the degree of freedom of motion of the tip position is extended, and new DSD mechanism was proposed. In order to control bending motion of the new DSD mechanism, inverse kinematics problem was analyzed, and equations which give the amount of rotations for each linkage were derived. To verify the validity of the derived equations, experimental works were carried out for the new DSD forceps manipulator
Construction of a regulating system for avoiding malpractice for robotic surgical support systems
研究成果の概要 (和文) : 本研究では、全方位の屈曲動作に対して力覚の伝達が可能な低侵襲外科手術用多自由度ロボット鉗子システムを開発し、遠隔操作において発生する通信時間遅れに対して安定性を保証するバイラテラル制御系を構成した。また、内視鏡下手術における手術手技に対して、鉗子の操作量から手術手技を識別し、さらに自己組織化マップを用いて、識別された手術手技を操作者の表面筋電位により、通常操作と特異操作に分類する方法を提案した。研究成果の概要 (英文) : In this research, a multi-DOF robotic forceps manipulator has been developed, and a bilateral control scheme which assures stability of the master-slave system in the presence of time varying communication delay between the master device and the slave device was proposed for omnidirectional bending motion of the developed robotic forceps. In addition, a method of identifying a surgical operation automatically and distinguishing the singularity of the identified surgical operation was also proposed. Based on the measurements of behavior of the forceps, the kind of surgical operation was identified. As for distinction of the singularity in surgical operation, the features were extracted from operator\u27s surface electromyogram signals, and the identified surgical operation was classified into normal or singular using the self-organizing map
Haptics in Robot-Assisted Surgery: Challenges and Benefits
Robotic surgery is transforming the current surgical practice, not only by improving the conventional surgical methods but also by introducing innovative robot-enhanced approaches that broaden the capabilities of clinicians. Being mainly of man-machine collaborative type, surgical robots are seen as media that transfer pre- and intra-operative information to the operator and reproduce his/her motion, with appropriate filtering, scaling, or limitation, to physically interact with the patient. The field, however, is far from maturity and, more critically, is still a subject of controversy in medical communities. Limited or absent haptic feedback is reputed to be among reasons that impede further spread of surgical robots. In this paper objectives and challenges of deploying haptic technologies in surgical robotics is discussed and a systematic review is performed on works that have studied the effects of providing haptic information to the users in major branches of robotic surgery. It has been tried to encompass both classical works and the state of the art approaches, aiming at delivering a comprehensive and balanced survey both for researchers starting their work in this field and for the experts
Function based control for motion control systems
Motion control systems are gaining importance as more and more sophisticated developments arise in technology. Technological improvements enhance incorporation of different research areas into the same framework while trying to make systems function in unstructured environments renders the design of control systems increasingly complex. Since motion systems are complex, they have complex forward or inverse kinematics, or interactions with other systems. In this study, motion of the systems is decomposed into the tasks, so called “functions”. Independent controllers are designed for these functions in the function space. It is proven that motion systems will be controlled in the original space if function based control outputs are superposed. Applicability of this method is demonstrated on bilateral systems and parallel mechanisms. Bilateral systems application proved that function based control can be used in controlling systems with interactions while establishing desired functional relation between them. Moreover, investigation of a pantograph and a three-legged manipulator, which come from the parallel mechanisms family and have nonlinear and coupled system dynamics, showed that creating an appropriate reference configuration to realize the task of motion control helps decouple system dynamics. Satisfactory simulation results show that functional control can be implemented and its characteristics promise successful future designs for motion control systems
Impact of Ear Occlusion on In-Ear Sounds Generated by Intra-oral Behaviors
We conducted a case study with one volunteer and a recording setup to detect sounds induced by the actions: jaw clenching, tooth grinding, reading, eating, and drinking. The setup consisted of two in-ear microphones, where the left ear was semi-occluded with a commercially available earpiece and the right ear was occluded with a mouldable silicon ear piece. Investigations in the time and frequency domains demonstrated that for behaviors such as eating, tooth grinding, and reading, sounds could be recorded with both sensors. For jaw clenching, however, occluding the ear with a mouldable piece was necessary to enable its detection. This can be attributed to the fact that the mouldable ear piece sealed the ear canal and isolated it from the environment, resulting in a detectable change in pressure. In conclusion, our work suggests that detecting behaviors such as eating, grinding, reading with a semi-occluded ear is possible, whereas, behaviors such as clenching require the complete occlusion of the ear if the activity should be easily detectable. Nevertheless, the latter approach may limit real-world applicability because it hinders the hearing capabilities.</p
A Sensorized Instrument for Minimally Invasive Surgery for the Measurement of Forces during Training and Surgery: Development and Applications
The reduced access conditions present in Minimally Invasive Surgery (MIS) affect the feel of interaction forces between the instruments and the tissue being treated. This loss of haptic information compromises the safety of the procedure and must be overcome through training. Haptics in MIS is the subject of extensive research, focused on establishing force feedback mechanisms and developing appropriate sensors. This latter task is complicated by the need to place the sensors as close as possible to the instrument tip, as the measurement of forces outside of the patient\u27s body does not represent the true tool--tissue interaction. Many force sensors have been proposed, but none are yet available for surgery. The objectives of this thesis were to develop a set of instruments capable of measuring tool--tissue force information in MIS, and to evaluate the usefulness of force information during surgery and for training and skills assessment. To address these objectives, a set of laparoscopic instruments was developed that can measure instrument position and tool--tissue interaction forces in multiple degrees of freedom. Different design iterations and the work performed towards the development of a sterilizable instrument are presented. Several experiments were performed using these instruments to establish the usefulness of force information in surgery and training. The results showed that the combination of force and position information can be used in the development of realistic tissue models or haptic interfaces specifically designed for MIS. This information is also valuable in order to create tactile maps to assist in the identification of areas of different stiffness. The real-time measurement of forces allows visual force feedback to be presented to the surgeon. When applied to training scenarios, the results show that experience level correlates better with force-based metrics than those currently used in training simulators. The proposed metrics can be automatically computed, are completely objective, and measure important aspects of performance. The primary contribution of this thesis is the design and development of highly versatile instruments capable of measuring force and position during surgery. A second contribution establishes the importance and usefulness of force data during skills assessment, training and surgery
Computational Intelligence in Electromyography Analysis
Electromyography (EMG) is a technique for evaluating and recording the electrical activity produced by skeletal muscles. EMG may be used clinically for the diagnosis of neuromuscular problems and for assessing biomechanical and motor control deficits and other functional disorders. Furthermore, it can be used as a control signal for interfacing with orthotic and/or prosthetic devices or other rehabilitation assists. This book presents an updated overview of signal processing applications and recent developments in EMG from a number of diverse aspects and various applications in clinical and experimental research. It will provide readers with a detailed introduction to EMG signal processing techniques and applications, while presenting several new results and explanation of existing algorithms. This book is organized into 18 chapters, covering the current theoretical and practical approaches of EMG research
A continuum robotic platform for endoscopic non-contact laser surgery: design, control, and preclinical evaluation
The application of laser technologies in surgical interventions has been accepted in the clinical
domain due to their atraumatic properties. In addition to manual application of fibre-guided
lasers with tissue contact, non-contact transoral laser microsurgery (TLM) of laryngeal tumours
has been prevailed in ENT surgery. However, TLM requires many years of surgical training
for tumour resection in order to preserve the function of adjacent organs and thus preserve the
patient’s quality of life. The positioning of the microscopic laser applicator outside the patient
can also impede a direct line-of-sight to the target area due to anatomical variability and limit
the working space. Further clinical challenges include positioning the laser focus on the tissue
surface, imaging, planning and performing laser ablation, and motion of the target area during
surgery. This dissertation aims to address the limitations of TLM through robotic approaches and
intraoperative assistance. Although a trend towards minimally invasive surgery is apparent, no
highly integrated platform for endoscopic delivery of focused laser radiation is available to date.
Likewise, there are no known devices that incorporate scene information from endoscopic imaging
into ablation planning and execution. For focusing of the laser beam close to the target tissue, this
work first presents miniaturised focusing optics that can be integrated into endoscopic systems.
Experimental trials characterise the optical properties and the ablation performance. A robotic
platform is realised for manipulation of the focusing optics. This is based on a variable-length
continuum manipulator. The latter enables movements of the endoscopic end effector in five
degrees of freedom with a mechatronic actuation unit. The kinematic modelling and control of the
robot are integrated into a modular framework that is evaluated experimentally. The manipulation
of focused laser radiation also requires precise adjustment of the focal position on the tissue. For
this purpose, visual, haptic and visual-haptic assistance functions are presented. These support
the operator during teleoperation to set an optimal working distance. Advantages of visual-haptic
assistance are demonstrated in a user study. The system performance and usability of the overall
robotic system are assessed in an additional user study. Analogous to a clinical scenario, the
subjects follow predefined target patterns with a laser spot. The mean positioning accuracy of the
spot is 0.5 mm. Finally, methods of image-guided robot control are introduced to automate laser
ablation. Experiments confirm a positive effect of proposed automation concepts on non-contact
laser surgery.Die Anwendung von Lasertechnologien in chirurgischen Interventionen hat sich aufgrund der atraumatischen Eigenschaften in der Klinik etabliert. Neben manueller Applikation von fasergeführten
Lasern mit Gewebekontakt hat sich die kontaktfreie transorale Lasermikrochirurgie (TLM) von
Tumoren des Larynx in der HNO-Chirurgie durchgesetzt. Die TLM erfordert zur Tumorresektion
jedoch ein langjähriges chirurgisches Training, um die Funktion der angrenzenden Organe zu
sichern und damit die Lebensqualität der Patienten zu erhalten. Die Positionierung des mikroskopis chen Laserapplikators außerhalb des Patienten kann zudem die direkte Sicht auf das Zielgebiet
durch anatomische Variabilität erschweren und den Arbeitsraum einschränken. Weitere klinische
Herausforderungen betreffen die Positionierung des Laserfokus auf der Gewebeoberfläche, die
Bildgebung, die Planung und Ausführung der Laserablation sowie intraoperative Bewegungen
des Zielgebietes. Die vorliegende Dissertation zielt darauf ab, die Limitierungen der TLM durch
robotische Ansätze und intraoperative Assistenz zu adressieren. Obwohl ein Trend zur minimal
invasiven Chirurgie besteht, sind bislang keine hochintegrierten Plattformen für die endoskopische
Applikation fokussierter Laserstrahlung verfügbar. Ebenfalls sind keine Systeme bekannt, die
Szeneninformationen aus der endoskopischen Bildgebung in die Ablationsplanung und -ausführung
einbeziehen. Für eine situsnahe Fokussierung des Laserstrahls wird in dieser Arbeit zunächst
eine miniaturisierte Fokussieroptik zur Integration in endoskopische Systeme vorgestellt. Experimentelle Versuche charakterisieren die optischen Eigenschaften und das Ablationsverhalten. Zur
Manipulation der Fokussieroptik wird eine robotische Plattform realisiert. Diese basiert auf einem
längenveränderlichen Kontinuumsmanipulator. Letzterer ermöglicht in Kombination mit einer
mechatronischen Aktuierungseinheit Bewegungen des Endoskopkopfes in fünf Freiheitsgraden.
Die kinematische Modellierung und Regelung des Systems werden in ein modulares Framework
eingebunden und evaluiert. Die Manipulation fokussierter Laserstrahlung erfordert zudem eine
präzise Anpassung der Fokuslage auf das Gewebe. Dafür werden visuelle, haptische und visuell haptische Assistenzfunktionen eingeführt. Diese unterstützen den Anwender bei Teleoperation
zur Einstellung eines optimalen Arbeitsabstandes. In einer Anwenderstudie werden Vorteile der
visuell-haptischen Assistenz nachgewiesen. Die Systemperformanz und Gebrauchstauglichkeit
des robotischen Gesamtsystems werden in einer weiteren Anwenderstudie untersucht. Analog zu
einem klinischen Einsatz verfolgen die Probanden mit einem Laserspot vorgegebene Sollpfade. Die
mittlere Positioniergenauigkeit des Spots beträgt dabei 0,5 mm. Zur Automatisierung der Ablation
werden abschließend Methoden der bildgestützten Regelung vorgestellt. Experimente bestätigen
einen positiven Effekt der Automationskonzepte für die kontaktfreie Laserchirurgie