734 research outputs found

    Deep Learning in Cardiology

    Full text link
    The medical field is creating large amount of data that physicians are unable to decipher and use efficiently. Moreover, rule-based expert systems are inefficient in solving complicated medical tasks or for creating insights using big data. Deep learning has emerged as a more accurate and effective technology in a wide range of medical problems such as diagnosis, prediction and intervention. Deep learning is a representation learning method that consists of layers that transform the data non-linearly, thus, revealing hierarchical relationships and structures. In this review we survey deep learning application papers that use structured data, signal and imaging modalities from cardiology. We discuss the advantages and limitations of applying deep learning in cardiology that also apply in medicine in general, while proposing certain directions as the most viable for clinical use.Comment: 27 pages, 2 figures, 10 table

    Combining Low-dimensional Wavelet Features and Support Vector Machine for Arrhythmia Beat Classification

    Get PDF
    Automatic feature extraction and classification are two main tasks in abnormal ECG beat recognition. Feature extraction is an important prerequisite prior to classification since it provides the classifier with input features, and the performance of classifier depends significantly on the quality of these features. This study develops an effective method to extract low-dimensional ECG beat feature vectors. It employs wavelet multi-resolution analysis to extract time-frequency domain features and then applies principle component analysis to reduce the dimension of the feature vector. In classification, 12-element feature vectors characterizing six types of beats are used as inputs for one-versus-one support vector machine, which is conducted in form of 10-fold cross validation with beat-based and record-based training schemes. Tested upon a total of 107049 beats from MIT-BIH arrhythmia database, our method has achieved average sensitivity, specificity and accuracy of 99.09%, 99.82% and 99.70%, respectively, using the beat-based training scheme, and 44.40%, 88.88% and 81.47%, respectively, using the record-based training scheme

    Activity-Aware Electrocardiogram-based Passive Ongoing Biometric Verification

    Get PDF
    Identity fraud due to lost, stolen or shared information or tokens that represent an individual\u27s identity is becoming a growing security concern. Biometric recognition - the identification or verification of claimed identity, shows great potential in bridging some of the existing security gaps. It has been shown that the human Electrocardiogram (ECG) exhibits sufficiently unique patterns for use in biometric recognition. But it also exhibits significant variability due to stress or activity, and signal artifacts due to movement. In this thesis, we develop a novel activity-aware ECG-based biometric recognition scheme that can verify/identify under different activity conditions. From a pattern recognition standpoint, we develop algorithms for preprocessing, feature extraction and probabilistic classification. We pay particular attention to the applicability of the proposed scheme in ongoing biometric verification of claimed identity. Finally we propose a wearable prototype architecture of our scheme

    A Panoramic Study of Fall Detection Technologies

    Get PDF
    Falls are a major risk of injury for elderly aged 65 or over, blind people, people with balance disorder and leg weakness. In this regard, assistive technology which aims to identify fall events at real time can reduce the rate of impairments and mortality. This study offer a literature research reference value for bioengineers for further research. Much of the past and the current fall detection research, the vital signals features and the way features are extracted and fed to a classifier are introduced. The study concludes with an assessment of the current technologies highlighting their critical limitations along with suggestions for future research direction in this rapidly developing field of study.http://dx.doi.org/10.20943/01201603.626

    Development of a Real-Time Single-Lead Single-Beat Frequency-Independent Myocardial Infarction Detector

    Get PDF
    The central aim of this research is the development and deployment of a novel multilayer machine learning design with unique application for the diagnosis of myocardial infarctions (MIs) from individual heartbeats of single-lead electrocardiograms (EKGs) irrespective of their sampling frequencies over a given range. To the best of our knowledge, this design is the first to attempt inter-patient myocardial infarction detection from individual heartbeats of single-lead (lead II) electrocardiograms that achieves high accuracy and near real-time diagnosis. The processing time of 300 milliseconds to a diagnosis is just at the time range in between extremely fast heartbeats of around 300 milliseconds, or 200 beats per minute. The design achieves stable performance metrics over the frequency range of 202Hz to 2.8kHz with an accuracy of 77.12%, positive predictive value (PPV) of 75.85%, and a negative predictive value (NPV) of 83.02% over the entire PTB database; 85.07%, 81.54%, 87.31% over the PTB-XL (the largest EKG database available for research) validation set, and 84.17%, 78.37%, 87.55% over the PTB-XL test set. Major design contributions and findings of this work reveal (1) a method for the realtime detection of ventricular depolarization events in the PQRST complex from 12-lead electrocardiograms using Independent Component Analysis (ICA), with a slightly different use of ICA proposed for electrocardiogram analysis and R-peak detection/localization; (2) a multilayer Long-Short Term Memory (LSTM) neural network design that identifies infarcted patients from a single heartbeat of a single-lead (lead II) electrocardiogram; (3) and integrated LSTM neural network with an algorithm that detects the R-peaks in real time for instantaneous detection of myocardial infarctions and for effective monitoring of patients under cardiac stress and/or at risk of myocardial infarction; (4) a fully integrated 12-lead real-time classifier with even higher detection metrics and a deeper neural architecture, which could serve as a near real-time monitoring tool that could gauge disease progression and evaluate benefits gained from early intervention and treatment planning; (5) a real-time frequency-independent design based on a single-lead single-beat MI detector, which is of pivotal importance to deployment as there is no standard sampling frequency for EKGs, making them span a wider frequency spectrum. vi

    Advanced Signal Processing in Wearable Sensors for Health Monitoring

    Get PDF
    Smart, wearables devices on a miniature scale are becoming increasingly widely available, typically in the form of smart watches and other connected devices. Consequently, devices to assist in measurements such as electroencephalography (EEG), electrocardiogram (ECG), electromyography (EMG), blood pressure (BP), photoplethysmography (PPG), heart rhythm, respiration rate, apnoea, and motion detection are becoming more available, and play a significant role in healthcare monitoring. The industry is placing great emphasis on making these devices and technologies available on smart devices such as phones and watches. Such measurements are clinically and scientifically useful for real-time monitoring, long-term care, and diagnosis and therapeutic techniques. However, a pertaining issue is that recorded data are usually noisy, contain many artefacts, and are affected by external factors such as movements and physical conditions. In order to obtain accurate and meaningful indicators, the signal has to be processed and conditioned such that the measurements are accurate and free from noise and disturbances. In this context, many researchers have utilized recent technological advances in wearable sensors and signal processing to develop smart and accurate wearable devices for clinical applications. The processing and analysis of physiological signals is a key issue for these smart wearable devices. Consequently, ongoing work in this field of study includes research on filtration, quality checking, signal transformation and decomposition, feature extraction and, most recently, machine learning-based methods

    Advanced Biometrics with Deep Learning

    Get PDF
    Biometrics, such as fingerprint, iris, face, hand print, hand vein, speech and gait recognition, etc., as a means of identity management have become commonplace nowadays for various applications. Biometric systems follow a typical pipeline, that is composed of separate preprocessing, feature extraction and classification. Deep learning as a data-driven representation learning approach has been shown to be a promising alternative to conventional data-agnostic and handcrafted pre-processing and feature extraction for biometric systems. Furthermore, deep learning offers an end-to-end learning paradigm to unify preprocessing, feature extraction, and recognition, based solely on biometric data. This Special Issue has collected 12 high-quality, state-of-the-art research papers that deal with challenging issues in advanced biometric systems based on deep learning. The 12 papers can be divided into 4 categories according to biometric modality; namely, face biometrics, medical electronic signals (EEG and ECG), voice print, and others
    corecore