3,671 research outputs found
Computerized Analysis of Magnetic Resonance Images to Study Cerebral Anatomy in Developing Neonates
The study of cerebral anatomy in developing neonates is of great importance for
the understanding of brain development during the early period of life. This
dissertation therefore focuses on three challenges in the modelling of cerebral
anatomy in neonates during brain development. The methods that have been
developed all use Magnetic Resonance Images (MRI) as source data.
To facilitate study of vascular development in the neonatal period, a set of image
analysis algorithms are developed to automatically extract and model cerebral
vessel trees. The whole process consists of cerebral vessel tracking from
automatically placed seed points, vessel tree generation, and vasculature
registration and matching. These algorithms have been tested on clinical Time-of-
Flight (TOF) MR angiographic datasets.
To facilitate study of the neonatal cortex a complete cerebral cortex segmentation
and reconstruction pipeline has been developed. Segmentation of the neonatal
cortex is not effectively done by existing algorithms designed for the adult brain
because the contrast between grey and white matter is reversed. This causes pixels
containing tissue mixtures to be incorrectly labelled by conventional methods. The
neonatal cortical segmentation method that has been developed is based on a novel
expectation-maximization (EM) method with explicit correction for mislabelled
partial volume voxels. Based on the resulting cortical segmentation, an implicit
surface evolution technique is adopted for the reconstruction of the cortex in
neonates. The performance of the method is investigated by performing a detailed
landmark study.
To facilitate study of cortical development, a cortical surface registration algorithm
for aligning the cortical surface is developed. The method first inflates extracted
cortical surfaces and then performs a non-rigid surface registration using free-form
deformations (FFDs) to remove residual alignment. Validation experiments using
data labelled by an expert observer demonstrate that the method can capture local
changes and follow the growth of specific sulcus
Hierarchical alignment of breast DCE-MR images by groupwise registration and robust feature matching: Breast DCE-MR image registration
Purpose: Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) shows high sensitivity in detecting breast cancer. However, its performance could be affected by patient motion during the imaging. To overcome this problem, it is necessary to correct patient motion by deformable registration, before using the DCE-MRI to detect breast cancer. However, deformable registration of DCE-MR images is challenging due to the dramatic contrast change over time (especially between the precontrast and postcontrast images). Most existing methods typically register each postcontrast image onto the precontrast image independently, without considering the dynamic contrast change after agent uptake. This could lead to the inconsistency among the aligned postcontrast images in the precontrast image space, which will eventually result in worse performance in cancer detection. In this paper, the authors present a novel hierarchical registration framework to address this problem
Unsupervised Deformable Image Registration Using Cycle-Consistent CNN
Medical image registration is one of the key processing steps for biomedical
image analysis such as cancer diagnosis. Recently, deep learning based
supervised and unsupervised image registration methods have been extensively
studied due to its excellent performance in spite of ultra-fast computational
time compared to the classical approaches. In this paper, we present a novel
unsupervised medical image registration method that trains deep neural network
for deformable registration of 3D volumes using a cycle-consistency. Thanks to
the cycle consistency, the proposed deep neural networks can take diverse pair
of image data with severe deformation for accurate registration. Experimental
results using multiphase liver CT images demonstrate that our method provides
very precise 3D image registration within a few seconds, resulting in more
accurate cancer size estimation.Comment: accepted for MICCAI 201
GIFTed Demons: deformable image registration with local structure-preserving regularization using supervoxels for liver applications.
Deformable image registration, a key component of motion correction in medical imaging, needs to be efficient and provides plausible spatial transformations that reliably approximate biological aspects of complex human organ motion. Standard approaches, such as Demons registration, mostly use Gaussian regularization for organ motion, which, though computationally efficient, rule out their application to intrinsically more complex organ motions, such as sliding interfaces. We propose regularization of motion based on supervoxels, which provides an integrated discontinuity preserving prior for motions, such as sliding. More precisely, we replace Gaussian smoothing by fast, structure-preserving, guided filtering to provide efficient, locally adaptive regularization of the estimated displacement field. We illustrate the approach by applying it to estimate sliding motions at lung and liver interfaces on challenging four-dimensional computed tomography (CT) and dynamic contrast-enhanced magnetic resonance imaging datasets. The results show that guided filter-based regularization improves the accuracy of lung and liver motion correction as compared to Gaussian smoothing. Furthermore, our framework achieves state-of-the-art results on a publicly available CT liver dataset
White Matter Structural Connectivity is Associated with Sensorimotor Function in Stroke Survivors
Purpose Diffusion tensor imaging (DTI) provides functionally relevant information about white matter structure. Local anatomical connectivity information combined with fractional anisotropy (FA) and mean diffusivity (MD) may predict functional outcomes in stroke survivors. Imaging methods for predicting functional outcomes in stroke survivors are not well established. This work uses DTI to objectively assess the effects of a stroke lesion on white matter structure and sensorimotor function. Methods A voxel-based approach is introduced to assess a stroke lesion\u27s global impact on motor function. Anatomical T1-weighted and diffusion tensor images of the brain were acquired for nineteen subjects (10 post-stroke and 9 age-matched controls). A manually selected volume of interest was used to alleviate the effects of stroke lesions on image registration. Images from all subjects were registered to the images of the control subject that was anatomically closest to Talairach space. Each subject\u27s transformed image was uniformly seeded for DTI tractography. Each seed was inversely transformed into the individual subject space, where DTI tractography was conducted and then the results were transformed back to the reference space. A voxel-wise connectivity matrix was constructed from the fibers, which was then used to calculate the number of directly and indirectly connected neighbors of each voxel. A novel voxel-wise indirect structural connectivity (VISC) index was computed as the average number of direct connections to a voxel\u27s indirect neighbors. Voxel-based analyses (VBA) were performed to compare VISC, FA, and MD for the detection of lesion-induced changes in sensorimotor function. For each voxel, a t-value was computed from the differences between each stroke brain and the 9 controls. A series of linear regressions was performed between Fugl-Meyer (FM) assessment scores of sensorimotor impairment and each DTI metric\u27s log number of voxels that differed from the control group. Results Correlation between the logarithm of the number of significant voxels in the ipsilesional hemisphere and total Fugl-Meyer score was moderate for MD (R2 = 0.512), and greater for VISC (R2 = 0.796) and FA (R2 = 0.674). The slopes of FA (p = 0.0036), VISC (p = 0.0005), and MD (p = 0.0199) versus the total FM score were significant. However, these correlations were driven by the upper extremity motor component of the FM score (VISC: R2 = 0.879) with little influence of the lower extremity motor component (FA: R2 = 0.177). Conclusion The results suggest that a voxel-wise metric based on DTI tractography can predict upper extremity sensorimotor function of stroke survivors, and that supraspinal intraconnectivity may have a less dominant role in lower extremity function
Image Registration for Quantitative Parametric Response Mapping of Cancer Treatment Response
AbstractImaging biomarkers capable of early quantification of tumor response to therapy would provide an opportunity to individualize patient care. Image registration of longitudinal scans provides a method of detecting treatment-associated changes within heterogeneous tumors by monitoring alterations in the quantitative value of individual voxels over time, which is unattainable by traditional volumetric-based histogram methods. The concepts involved in the use of image registration for tracking and quantifying breast cancer treatment response using parametric response mapping (PRM), a voxel-based analysis of diffusion-weighted magnetic resonance imaging (DW-MRI) scans, are presented. Application of PRM to breast tumor response detection is described, wherein robust registration solutions for tracking small changes in water diffusivity in breast tumors during therapy are required. Methodologies that employ simulations are presented for measuring expected statistical accuracy of PRM for response assessment. Test-retest clinical scans are used to yield estimates of system noise to indicate significant changes in voxel-based changes in water diffusivity. Overall, registration-based PRM image analysis provides significant opportunities for voxel-based image analysis to provide the required accuracy for early assessment of response to treatment in breast cancer patients receiving neoadjuvant chemotherapy
- …