2,625 research outputs found
Attention Gated Networks: Learning to Leverage Salient Regions in Medical Images
We propose a novel attention gate (AG) model for medical image analysis that
automatically learns to focus on target structures of varying shapes and sizes.
Models trained with AGs implicitly learn to suppress irrelevant regions in an
input image while highlighting salient features useful for a specific task.
This enables us to eliminate the necessity of using explicit external
tissue/organ localisation modules when using convolutional neural networks
(CNNs). AGs can be easily integrated into standard CNN models such as VGG or
U-Net architectures with minimal computational overhead while increasing the
model sensitivity and prediction accuracy. The proposed AG models are evaluated
on a variety of tasks, including medical image classification and segmentation.
For classification, we demonstrate the use case of AGs in scan plane detection
for fetal ultrasound screening. We show that the proposed attention mechanism
can provide efficient object localisation while improving the overall
prediction performance by reducing false positives. For segmentation, the
proposed architecture is evaluated on two large 3D CT abdominal datasets with
manual annotations for multiple organs. Experimental results show that AG
models consistently improve the prediction performance of the base
architectures across different datasets and training sizes while preserving
computational efficiency. Moreover, AGs guide the model activations to be
focused around salient regions, which provides better insights into how model
predictions are made. The source code for the proposed AG models is publicly
available.Comment: Accepted for Medical Image Analysis (Special Issue on Medical Imaging
with Deep Learning). arXiv admin note: substantial text overlap with
arXiv:1804.03999, arXiv:1804.0533
Recommended from our members
Development of advanced 3D medical analysis tools for clinical training, diagnosis and treatment
This thesis was submitted for the degree of Doctor of Philosophy and awarded by Brunel University.The objective of this PhD research was the development of novel 3D interactive medical platforms for medical image analysis, simulation and visualisation, with a focus on oncology images to support clinicians in managing the increasing amount of data provided by several medical image modalities.
DoctorEye and Automatic Tumour Detector platforms were developed through constant interaction and feedback from expert clinicians, integrating a number of innovations in algorithms and methods, concerning image handling, segmentation, annotation, visualisation and plug-in technologies. DoctorEye is already being used in a related tumour modelling EC project (ContraCancrum) and offers several robust algorithms and tools for fast annotation, 3D visualisation and measurements to assist the clinician in better understanding the pathology of the brain area and define the treatment. It is free to use upon request and offers a user friendly environment for clinicians as it simplifies the implementation of complex algorithms and methods. It integrates a sophisticated, simple-to-use plug-in technology allowing researchers to add algorithms and methods (e.g. tumour growth and simulation algorithms for improving therapy planning) and interactively check the results. Apart from diagnostic and research purposes, it supports clinical training as it allows an expert clinician to evaluate a clinical delineation by different clinical users. The Automatic Tumour Detector focuses on abdominal images, which are more complex than those of the brain. It supports full automatic 3D detection of kidney pathology in real-time as well as 3D advanced visualisation and measurements. This is achieved through an innovative method implementing Templates. They contain rules and parameters for the Automatic Recognition Framework defined interactively by engineers based on clinicians’ 3D Golden Standard models. The Templates enable the automatic detection of kidneys and their possible abnormalities (tumours, stones and cysts). The system also supports the transmission of these Templates to another expert for a second opinion. Future versions of the proposed platforms could integrate even more sophisticated algorithms and tools and offer fully computer-aided identification of a variety of other organs and their dysfunctions
Single-breath-hold photoacoustic computed tomography of the breast
We have developed a single-breath-hold photoacoustic computed tomography (SBH-PACT) system to reveal detailed angiographic structures in human breasts. SBH-PACT features a deep penetration depth (4 cm in vivo) with high spatial and temporal resolutions (255 µm in-plane resolution and a 10 Hz 2D frame rate). By scanning the entire breast within a single breath hold (~15 s), a volumetric image can be acquired and subsequently reconstructed utilizing 3D back-projection with negligible breathing-induced motion artifacts. SBH-PACT clearly reveals tumors by observing higher blood vessel densities associated with tumors at high spatial resolution, showing early promise for high sensitivity in radiographically dense breasts. In addition to blood vessel imaging, the high imaging speed enables dynamic studies, such as photoacoustic elastography, which identifies tumors by showing less compliance. We imaged breast cancer patients with breast sizes ranging from B cup to DD cup, and skin pigmentations ranging from light to dark. SBH-PACT identified all the tumors without resorting to ionizing radiation or exogenous contrast, posing no health risks
Automated quantification and classification of human kidney microstructures obtained by optical coherence tomography
Optical coherence tomography (OCT) is a rapidly emerging imaging modality that can non-invasively provide cross-sectional, high-resolution images of tissue morphology such as kidney in situ and in real-time. Because the viability of a donor kidney is closely correlated with its tubular morphology, and a large amount of image datasets are expected when using OCT to scan the entire kidney, it is necessary to develop automated image analysis methods to quantify the spatially-resolved morphometric parameters such as tubular diameter, and to classify various microstructures. In this study, we imaged the human kidney in vitro, quantified the diameters of hollow structures such as blood vessels and uriniferous tubules, and classified those structures automatically. The quantification accuracy was validated. This work can enable studies to determine the clinical utility of OCT for kidney imaging, as well as studies to evaluate kidney morphology as a biomarker for assessing kidney's viability prior to transplantation
Recent Advances in Machine Learning Applied to Ultrasound Imaging
Machine learning (ML) methods are pervading an increasing number of fields of application because of their capacity to effectively solve a wide variety of challenging problems. The employment of ML techniques in ultrasound imaging applications started several years ago but the scientific interest in this issue has increased exponentially in the last few years. The present work reviews the most recent (2019 onwards) implementations of machine learning techniques for two of the most popular ultrasound imaging fields, medical diagnostics and non-destructive evaluation. The former, which covers the major part of the review, was analyzed by classifying studies according to the human organ investigated and the methodology (e.g., detection, segmentation, and/or classification) adopted, while for the latter, some solutions to the detection/classification of material defects or particular patterns are reported. Finally, the main merits of machine learning that emerged from the study analysis are summarized and discussed. © 2022 by the authors. Licensee MDPI, Basel, Switzerland
A non-invasive diagnostic system for early assessment of acute renal transplant rejection.
Early diagnosis of acute renal transplant rejection (ARTR) is of immense importance for appropriate therapeutic treatment administration. Although the current diagnostic technique is based on renal biopsy, it is not preferred due to its invasiveness, recovery time (1-2 weeks), and potential for complications, e.g., bleeding and/or infection. In this thesis, a computer-aided diagnostic (CAD) system for early detection of ARTR from 4D (3D + b-value) diffusion-weighted (DW) MRI data is developed. The CAD process starts from a 3D B-spline-based data alignment (to handle local deviations due to breathing and heart beat) and kidney tissue segmentation with an evolving geometric (level-set-based) deformable model. The latter is guided by a voxel-wise stochastic speed function, which follows from a joint kidney-background Markov-Gibbs random field model accounting for an adaptive kidney shape prior and for on-going visual kidney-background appearances. A cumulative empirical distribution of apparent diffusion coefficient (ADC) at different b-values of the segmented DW-MRI is considered a discriminatory transplant status feature. Finally, a classifier based on deep learning of a non-negative constrained stacked auto-encoder is employed to distinguish between rejected and non-rejected renal transplants. In the “leave-one-subject-out” experiments on 53 subjects, 98% of the subjects were correctly classified (namely, 36 out of 37 rejected transplants and 16 out of 16 nonrejected ones). Additionally, a four-fold cross-validation experiment was performed, and an average accuracy of 96% was obtained. These experimental results hold promise of the proposed CAD system as a reliable non-invasive diagnostic tool
Analysis of contrast-enhanced medical images.
Early detection of human organ diseases is of great importance for the accurate diagnosis and institution of appropriate therapies. This can potentially prevent progression to end-stage disease by detecting precursors that evaluate organ functionality. In addition, it also assists the clinicians for therapy evaluation, tracking diseases progression, and surgery operations. Advances in functional and contrast-enhanced (CE) medical images enabled accurate noninvasive evaluation of organ functionality due to their ability to provide superior anatomical and functional information about the tissue-of-interest. The main objective of this dissertation is to develop a computer-aided diagnostic (CAD) system for analyzing complex data from CE magnetic resonance imaging (MRI). The developed CAD system has been tested in three case studies: (i) early detection of acute renal transplant rejection, (ii) evaluation of myocardial perfusion in patients with ischemic heart disease after heart attack; and (iii), early detection of prostate cancer. However, developing a noninvasive CAD system for the analysis of CE medical images is subject to multiple challenges, including, but are not limited to, image noise and inhomogeneity, nonlinear signal intensity changes of the images over the time course of data acquisition, appearances and shape changes (deformations) of the organ-of-interest during data acquisition, determination of the best features (indexes) that describe the perfusion of a contrast agent (CA) into the tissue. To address these challenges, this dissertation focuses on building new mathematical models and learning techniques that facilitate accurate analysis of CAs perfusion in living organs and include: (i) accurate mathematical models for the segmentation of the object-of-interest, which integrate object shape and appearance features in terms of pixel/voxel-wise image intensities and their spatial interactions; (ii) motion correction techniques that combine both global and local models, which exploit geometric features, rather than image intensities to avoid problems associated with nonlinear intensity variations of the CE images; (iii) fusion of multiple features using the genetic algorithm. The proposed techniques have been integrated into CAD systems that have been tested in, but not limited to, three clinical studies. First, a noninvasive CAD system is proposed for the early and accurate diagnosis of acute renal transplant rejection using dynamic contrast-enhanced MRI (DCE-MRI). Acute rejection–the immunological response of the human immune system to a foreign kidney–is the most sever cause of renal dysfunction among other diagnostic possibilities, including acute tubular necrosis and immune drug toxicity. In the U.S., approximately 17,736 renal transplants are performed annually, and given the limited number of donors, transplanted kidney salvage is an important medical concern. Thus far, biopsy remains the gold standard for the assessment of renal transplant dysfunction, but only as the last resort because of its invasive nature, high cost, and potential morbidity rates. The diagnostic results of the proposed CAD system, based on the analysis of 50 independent in-vivo cases were 96% with a 95% confidence interval. These results clearly demonstrate the promise of the proposed image-based diagnostic CAD system as a supplement to the current technologies, such as nuclear imaging and ultrasonography, to determine the type of kidney dysfunction. Second, a comprehensive CAD system is developed for the characterization of myocardial perfusion and clinical status in heart failure and novel myoregeneration therapy using cardiac first-pass MRI (FP-MRI). Heart failure is considered the most important cause of morbidity and mortality in cardiovascular disease, which affects approximately 6 million U.S. patients annually. Ischemic heart disease is considered the most common underlying cause of heart failure. Therefore, the detection of the heart failure in its earliest forms is essential to prevent its relentless progression to premature death. While current medical studies focus on detecting pathological tissue and assessing contractile function of the diseased heart, this dissertation address the key issue of the effects of the myoregeneration therapy on the associated blood nutrient supply. Quantitative and qualitative assessment in a cohort of 24 perfusion data sets demonstrated the ability of the proposed framework to reveal regional perfusion improvements with therapy, and transmural perfusion differences across the myocardial wall; thus, it can aid in follow-up on treatment for patients undergoing the myoregeneration therapy. Finally, an image-based CAD system for early detection of prostate cancer using DCE-MRI is introduced. Prostate cancer is the most frequently diagnosed malignancy among men and remains the second leading cause of cancer-related death in the USA with more than 238,000 new cases and a mortality rate of about 30,000 in 2013. Therefore, early diagnosis of prostate cancer can improve the effectiveness of treatment and increase the patient’s chance of survival. Currently, needle biopsy is the gold standard for the diagnosis of prostate cancer. However, it is an invasive procedure with high costs and potential morbidity rates. Additionally, it has a higher possibility of producing false positive diagnosis due to relatively small needle biopsy samples. Application of the proposed CAD yield promising results in a cohort of 30 patients that would, in the near future, represent a supplement of the current technologies to determine prostate cancer type. The developed techniques have been compared to the state-of-the-art methods and demonstrated higher accuracy as shown in this dissertation. The proposed models (higher-order spatial interaction models, shape models, motion correction models, and perfusion analysis models) can be used in many of today’s CAD applications for early detection of a variety of diseases and medical conditions, and are expected to notably amplify the accuracy of CAD decisions based on the automated analysis of CE images
Diffusion-weighted magnetic resonance imaging in diagnosing graft dysfunction : a non-invasive alternative to renal biopsy.
The thesis is divided into three parts. The first part focuses on background information including how the kidney functions, diseases, and available kidney disease treatment strategies. In addition, the thesis provides information on imaging instruments and how they can be used to diagnose renal graft dysfunction. The second part focuses on elucidating the parameters linked with highly accurate diagnosis of rejection. Four parameters categories were tested: clinical biomarkers alone, individual mean apparent diffusion coefficient (ADC) at 11-different b- values, mean ADCs of certain groups of b-value, and fusion of clinical biomarkers and all b-values. The most accurate model was found to be when the b-value of b=100 s/mm2 and b=700 s/mm2 were fused. The third part of this thesis focuses on a study that uses Diffusion-Weighted MRI to diagnose and differentiate two types of renal rejection. The system was found to correctly differentiate the two types of rejection with a 98% accuracy. The last part of this thesis concludes the work that has been done and states the possible trends and future avenues
Segmentation of Calculi from Ultrasound Kidney Images by Region Indictor with Contour Segmentation Method
In this proposed Region Indicator with Contour Segmentation (RICS) method, five major steps are followed to select the exact calculi region from the renal calculi images. In the first and second stage, the region indices library and renal calculi region parameters are computed. After that, the image contrast is enhanced by the Histogram Equalization and the most interested pixel values of enhanced image are selected by the k-means clustering. The most interested pixel values are utilized to find the accurate calculi from the renal images. In the final stage, a number of regions are selected based on the contour process. Subsequently, pixel matching and sequence of thresholding process are performed to find the calculi. In addition, the usage of ANFIS in supervised learning has made the technique more efficient than the previous techniques. Here, the utilization of contour reduces the relative error in between the Expert radiologist and the segmented calculi, which are obtained from the proposed algorithm. Thus, the obtained error is minimized that leads to high efficiency. The implementation result shows the effectiveness of the proposed RICS segmentation method in segmenting the renal calculi in terms of sensitivity and specificity. And also, the proposed method improves the calculi area detection accuracy with reduced in computational time
- …