8,056 research outputs found

    Parameter Optimisation of a Virtual Synchronous Machine in a Microgrid

    Full text link
    Parameters of a virtual synchronous machine in a small microgrid are optimised. The dynamical behaviour of the system is simulated after a perturbation, where the system needs to return to its steady state. The cost functional evaluates the system behaviour for different parameters. This functional is minimised by Parallel Tempering. Two perturbation scenarios are investigated and the resulting optimal parameters agree with analytical predictions. Dependent on the focus of the optimisation different optima are obtained for each perturbation scenario. During the transient the system leaves the allowed voltage and frequency bands only for a short time if the perturbation is within a certain range.Comment: 17 pages, 5 figure

    Increasing security of supply by the use of a local power controller during large system disturbances

    Get PDF
    This paper describes intelligent ways in which distributed generation and local loads can be controlled during large system disturbances, using Local Power Controllers. When distributed generation is available, and a system disturbance is detected early enough, the generation can be dispatched, and its output power can be matched as closely as possible to local microgrid demand levels. Priority-based load shedding can be implemented to aid this process. In this state, the local microgrid supports the wider network by relieving the wider network of the micro-grid load. Should grid performance degrade further, the local microgrid can separate itself from the network and maintain power to the most important local loads, re-synchronising to the grid only after more normal performance is regained. Such an intelligent system would be a suitable for hospitals, data centres, or any other industrial facility where there are critical loads. The paper demonstrates the actions of such Local Power Controllers using laboratory experiments at the 10kVA scale

    Offshore Wind Farm Black Start Service Integration:Review and Outlook of Ongoing Research

    Get PDF
    A review of the ongoing research on black start (BS) service integrated with offshore wind farms (OWFs) is presented in this paper. The overall goal is to firstly gain a better understanding of the BS capabilities required by modern power systems. Subsequently, the challenges faced by OWFs as novel BS service providers as well as an outlook on the ongoing research which may provide solutions to these are presented. OWFs have the potential to be a fast and environmentally friendly technology to provide BS services for power system restoration and, therefore, to ensure resiliency after blackouts. As a power electronic-based system, OWFs can be equipped with a self-starter in the system in order to perform BS. The self-start unit could be a synchronous generator (SG) or a power electronic unit such as a grid-forming (GFM) converter. Preliminary BS studies performed in PSCAD/EMTDC are presented in a simplified OWF system via an SG as the self-start unit. Consequently, technical challenges during the BS procedure in an OWF benchmark system are outlined via theoretical discussions and simulations results. This is useful to understand the threats to power electronics during BS. Finally, the most relevant GFM strategies in the state-of-the-art literature are presented and their application to OWF BS is discussed

    European White Book on Real-Time Power Hardware in the Loop Testing : DERlab Report No. R- 005.0

    Get PDF
    The European White Book on Real-Time-Powerhardware-in-the-Loop testing is intended to serve as a reference document on the future of testing of electrical power equipment, with speciïŹ c focus on the emerging hardware-in-the-loop activities and application thereof within testing facilities and procedures. It will provide an outlook of how this powerful tool can be utilised to support the development, testing and validation of speciïŹ cally DER equipment. It aims to report on international experience gained thus far and provides case studies on developments and speciïŹ c technical issues, such as the hardware/software interface. This white book compliments the already existing series of DERlab European white books, covering topics such as grid-inverters and grid-connected storag

    Virtually synchronous power plant control

    Get PDF
    During the last century, the electrical energy infrastructures have been governed by synchronous generators, producing electrical energy to the vast majority of the population worldwide. However, power systems are no longer what they used to be. During the last two decades of this new millennium the classical, centralized and hierarchical networks have experienced an intense integration of renewable energy sources, mainly wind and solar, thanks also to the evolution and development of power conversion and power electronics industry. Although the current electrical system was designed to have a core of generation power plants, responsible of producing the necessary energy to supply end users and a clear power flow, divided mainly into transmission and distribution networks, as well as scalable consumers connected at different levels, this scenario has dramatically changed with the addition of renewable generation units. The massive installation of wind and solar farms, connected at medium voltage networks, as well as the proliferation of small distributed generators interfaced by power converters in low voltage systems is changing the paradigm of energy generation, distribution and consumption. Despite the feasibility of this integration in the existing electrical network, the addition of these distributed generators made grid operators face new challenges, especially considering the stochastic profile of such energy producers. Furthermore, the replacement of traditional generation units for renewable energy sources has harmed the stability and the reliable response during grid contingencies. In order to cope with the difficult task of operating the electrical network, transmission system operators have increased the requirements and modified the grid codes for the newly integrated devices. In an effort to enable a more natural behavior of the renewable systems into the electrical grid, advanced control strategies were presented in the literature to emulate the behavior of traditional synchronous generators. These approaches focused mainly on the power converter relying on their local measurement points to resemble the operation of a traditional generating unit. However, the integration of those units into bigger systems, such as power plants, is still not clear as the effect of accumulating hundreds or thousands of units has not been properly addressed. In this regard, the work of this thesis deals with the study of the so-called virtual synchronous machine (VSM) in three control layers. Furthermore, an in-depth analysis of the general structure used for the different virtual synchronous machine approaches is presented, which constitutes the base implementation tree for all existent strategies of virtual synchronous generation. In a first stage, the most inner control loop is studied and analyzed regarding the current control on the power converter. This internal regulator is in charge of the current injection and the tracking of all external power reference. Afterward, the synchronous control is oriented to the device, where the generating unit relies on its local measurements to emulate a synchronous machine in the power converter. In this regard, a sensorless approach to the virtual synchronous machine is introduced, increasing the stability of the power converter and reducing the voltage measurements used. Finally, the model of the synchronous control is extrapolated into a power plant control layer to be able to regulate multiple units in a coordinated manner, thus emulating the behavior of a unique synchronous machine. In this regard, the local measurements are not used for the emulation of the virtual machine, but they are switched to PCC measurements, allowing to set the desired dynamic response at the power plant level.Postprint (published version

    Virtual synchronous generator: an overview

    Get PDF
    The continuous increase in the penetration of renewable energy (RE) based distributed generations (DGs) in the power system network has created a great concern on the stability of the existing grid. Traditional bulk power plants, which are dominated by synchronous machines (SMs) can easily support system instability, due to the inherent rotor inertia and damping characteristic, as well as voltage (reactive power) control ability. Nevertheless, converter based RE has some special characteristics, such as stochastic real and reactive power output, quick active and reactive power response, small output impedance, and little or no inertia and damping property thereby causing frequency and voltage instability in the system. To solve this problem, virtual synchronous generator (VSG) concept was proposed to emulate some of the features of conventional SG through converter control strategy in order to provide additional inertia virtually. Different control schemes for VSG has been proposed in literature. Surprisingly, an overview of these schemes is yet to be efficiently presented. This paper presents an overview of the VSG control schemes. It provides the concepts, the features of the control schemes and the applications of VSG. Finally, the crucial issues regarding VSG control schemes and the necessary improvement that need to be addressed are highlighted.Keywords: Distributed generation, Synchronous generator, Virtual synchronous generator, Power electronicv converter, Energy storage system, Frequency contro

    Experimental stability assessment of converter-dominated electrical grids

    Get PDF
    With the inclusion of renewable generation into the electrical grid, traditional fossil-fueled plants based on synchronous generators have been gradually replaced by converterbased systems, controlled using the standard vectorial current control (DQCI). From the grid point of view, this control strategy makes converter behave as current sources that inject power to the grid but have limited magnitude or angle voltage regulation. The shortage of this task implies a detriment of the stability of key parameters for a stable grid, exposing the system to huge diversions of frequency and voltage. Ultimately, this can make generators to disconnect, compromising with it the stability of the whole system thanks to a cascade failure. However, as it will be seen in this paper, it is possible to transform the converter into a real regulating voltage source changing just the control algorithm. Thanks to this change, same converters can create now reference nodes (also called grid building nodes) in the grid which DQCI converters can follow. This scheme would allow the possibility to a robust system based completely on converters. This scenario is object of test in this paper where a power quality and stability assessment is conducted in the lab
    • 

    corecore