8,418 research outputs found

    Effects of POD control on a DFIG wind turbine structural system

    Get PDF
    This paper investigates the effects power oscillation damping (POD) controller could have on a wind turbine structural system. Most of the published work in this area has been done using relatively simple aerodynamic and structural models of a wind turbine which cannot be used to investigate the detailed interactions between electrical and mechanical components of the wind turbine. Therefore, a detailed model that combines electrical, structural and aerodynamic characteristics of a grid-connected Doubly Fed Induction Generator (DFIG) based wind turbine has been developed by adapting the NREL (National Renewable Energy Laboratory) 5MW wind turbine model within FAST (Fatigue, Aerodynamics, Structures, and Turbulence) code. This detailed model is used to evaluate the effects of POD controller on the wind turbine system. The results appear to indicate that the effects of POD control on the WT structural system are comparable or less significant as those caused by wind speed variations. Furthermore, the results also reveal that the effects of a transient three-phase short circuit fault on the WT structural system are much larger than those caused by the POD controller

    Doktrin pengasingan kuasa : falsafah, praktis dan kerelatifan di Malaysia

    Get PDF
    Penulisan ini membincangkan tentang doktrin pengasingan kuasa berdasarkan kerangka teori institusionalisme. Doktrin ini dipraktiskan dalam trias politica atau politik tiga serangkai iaitu badan legislatif, eksekutif dan kehakiman. Falsafah dan praktis doktrin pengasingan kuasa ini adalah ditekankan bagi sesebuah negara bercorak demokrasi untuk mempamerkan wujudnya pengasingan kuasa serta autonomi bidangan di antara ketigatiga badan kerajaan. Hal ini penting untuk disoroti kerana Malaysia tidak terkecuali daripada mengamalkan sistem demokrasi dan pada masa yang sama mempraktiskan doktrin pengasingan kuasa dalam kerajaan federalisme berlapisnya sebagai satu pegangan fundamental. Akauntabiliti untuk menzahirkan doktrin pengasingan kuasa ini merupakan perkara yang penting memandangkan ia telah dimaktubkan dalam Perlembagaan Persekutuan

    Review of Power System Stability with High Wind Power Penetration

    Get PDF

    Mitigating the erosion of transient stability margins in Great Britain through novel wind farm control techniques

    Get PDF
    The predominant North-to-South active power flow across the border between Scotland and England has historically been limited by system stability considerations. As the penetration of variable-speed wind power plants in Great Britain grows (reducing the generation share of traditional synchronous generation), it is imperative that stability limits, operational flexibility, efficiency and system security are not unduly eroded as a result. The studies reported in this thesis illustrate the impacts on critical fault clearing times and active power transfer limits through this North-South corridor, known as the B6 boundary, in the presence of increasing penetrations of wind power generation on the GB transmission system. By focussing on the transient behaviour of a representative reduced test system following a three-phase short-circuit fault occurring on one of the two double-circuits constituting the B6 boundary, the impacts on the transient stability margins are qualitatively identified. There is a pressing necessity for new wind farms to be able to mitigate, as much as possible, their own negative impacts on system stability margins. The transient stability improvement achieved by tailoring the low voltage ride-through reactive power control response of wind farms is first investigated, and a novel control technique is then presented which can significantly mitigate the erosion of the transient stability performance of power systems, in the presence of in-creasing amounts of wind power, by tailoring the immediate post-fault active power recovery ramp-rates of the wind power plants around the system. The impacts of these control techniques on critical fault clearing times and power transfer limits are investigated. In particular, it has been found that the use of slower active power recovery from wind farms located in exporting regions when a short circuit fault occurs on the export corridor will provide significant benefits for both of these metrics, while a faster active power recovery in importing regions will provide a similar transient stability benefit. However, it is also shown that there are potential detrimental effects for system frequency stability. In addition, important impacts of wind farm settings in respect of low voltage ride through are revealed whereby the LVRT controls can act to erode stability margins if careful consideration of their settings is not taken. Assuming a future power system with high levels of centralised observability and controllability (or decentralised co-operative control systems), it may be possible to continually “dispatch” the reactive power gains and active power recovery ramp rates discussed in this thesis to match the current system setpoint and to seek an optimal transient response to a range of credible contingencies.The predominant North-to-South active power flow across the border between Scotland and England has historically been limited by system stability considerations. As the penetration of variable-speed wind power plants in Great Britain grows (reducing the generation share of traditional synchronous generation), it is imperative that stability limits, operational flexibility, efficiency and system security are not unduly eroded as a result. The studies reported in this thesis illustrate the impacts on critical fault clearing times and active power transfer limits through this North-South corridor, known as the B6 boundary, in the presence of increasing penetrations of wind power generation on the GB transmission system. By focussing on the transient behaviour of a representative reduced test system following a three-phase short-circuit fault occurring on one of the two double-circuits constituting the B6 boundary, the impacts on the transient stability margins are qualitatively identified. There is a pressing necessity for new wind farms to be able to mitigate, as much as possible, their own negative impacts on system stability margins. The transient stability improvement achieved by tailoring the low voltage ride-through reactive power control response of wind farms is first investigated, and a novel control technique is then presented which can significantly mitigate the erosion of the transient stability performance of power systems, in the presence of in-creasing amounts of wind power, by tailoring the immediate post-fault active power recovery ramp-rates of the wind power plants around the system. The impacts of these control techniques on critical fault clearing times and power transfer limits are investigated. In particular, it has been found that the use of slower active power recovery from wind farms located in exporting regions when a short circuit fault occurs on the export corridor will provide significant benefits for both of these metrics, while a faster active power recovery in importing regions will provide a similar transient stability benefit. However, it is also shown that there are potential detrimental effects for system frequency stability. In addition, important impacts of wind farm settings in respect of low voltage ride through are revealed whereby the LVRT controls can act to erode stability margins if careful consideration of their settings is not taken. Assuming a future power system with high levels of centralised observability and controllability (or decentralised co-operative control systems), it may be possible to continually “dispatch” the reactive power gains and active power recovery ramp rates discussed in this thesis to match the current system setpoint and to seek an optimal transient response to a range of credible contingencies

    A review of utility issues for the integration of wind electric generators

    Get PDF
    A review of issues and concerns of the electric utility industry for the integration of wind electric generation is offered. The issues have been categorized in three major areas: planning, operations, and dynamic interaction. Representative studies have been chosen for each area to illustrate problems and to alleviate some concerns. The emphasis of this paper is on individual large wind turbines (WTs) and WT arrays for deployment at the bulk level in a utility system

    Distributed photovoltaic systems: Utility interface issues and their present status. Intermediate/three-phase systems

    Get PDF
    The interface issues between the intermediate-size Power Conditioning Subsystem (PCS) and the utility are considered. A literature review yielded facts about the status of identified issues

    Impacts of high penetration of DFIG wind turbines on rotor angle stability of power systems

    Get PDF
    With the integration of wind power into power systems continues to increase, the impact of high penetration of wind power on power system stability becomes a very important issue. This paper investigates the impact of doubly fed induction generator (DFIG) control and operation on rotor angle stability. Acontrol strategy for both the rotor-side converter (RSC) and grid-side converter (GSC) of the DFIG is proposed to mitigate DFIGs impacts on the system stability. DFIG-GSC is utilized to be controlled as static synchronous compensator (STATCOM) to provide reactive power support during grid faults. In addition, a power system stabilizer (PSS) is implemented in the reactive power control loop of DFIG-RSC. The proposed approaches are validated on a realistic Western System Coordinating Council (WSCC) power system under both small and large disturbances. The simulation results show the effectiveness and robustness of both DFIG-GSC control strategy and PSS to enhance rotor angle stability of power system
    • 

    corecore