307,493 research outputs found

    Solid immersion lens applications for nanophotonic devices

    Get PDF
    Solid immersion lens (SIL) microscopy combines the advantages of conventional microscopy with those of near-field techniques, and is being increasingly adopted across a diverse range of technologies and applications. A comprehensive overview of the state-of-the-art in this rapidly expanding subject is therefore increasingly relevant. Important benefits are enabled by SIL-focusing, including an improved lateral and axial spatial profiling resolution when a SIL is used in laser-scanning microscopy or excitation, and an improved collection efficiency when a SIL is used in a light-collection mode, for example in fluorescence micro-spectroscopy. These advantages arise from the increase in numerical aperture (NA) that is provided by a SIL. Other SIL-enhanced improvements, for example spherical-aberration-free sub-surface imaging, are a fundamental consequence of the aplanatic imaging condition that results from the spherical geometry of the SIL. Beginning with an introduction to the theory of SIL imaging, the unique properties of SILs are exposed to provide advantages in applications involving the interrogation of photonic and electronic nanostructures. Such applications range from the sub-surface examination of the complex three-dimensional microstructures fabricated in silicon integrated circuits, to quantum photoluminescence and transmission measurements in semiconductor quantum dot nanostructures

    Spectroscopic scanning tunneling microscopy insights into Fe-based superconductors

    Get PDF
    In the first three years since the discovery of Fe-based high Tc superconductors, scanning tunneling microscopy (STM) and spectroscopy have shed light on three important questions. First, STM has demonstrated the complexity of the pairing symmetry in Fe-based materials. Phase-sensitive quasiparticle interference (QPI) imaging and low temperature spectroscopy have shown that the pairing order parameter varies from nodal to nodeless s\pm within a single family, FeTe1-xSex. Second, STM has imaged C4 -> C2 symmetry breaking in the electronic states of both parent and superconducting materials. As a local probe, STM is in a strong position to understand the interactions between these broken symmetry states and superconductivity. Finally, STM has been used to image the vortex state, giving insights into the technical problem of vortex pinning, and the fundamental problem of the competing states introduced when superconductivity is locally quenched by a magnetic field. Here we give a pedagogical introduction to STM and QPI imaging, discuss the specific challenges associated with extracting bulk properties from the study of surfaces, and report on progress made in understanding Fe-based superconductors using STM techniques.Comment: 36 pages, 23 figures, 229 reference

    Impact of picture archiving communication systems on rates of duplicate imaging: a before-after study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Electronic health information systems, such as picture archiving communication systems (PACS), are commonly believed to reduce the need for duplicate testing. However, empirical data to support this belief are not available.</p> <p>Methods</p> <p>Before-after study using administrative claims data from the Ontario Health Insurance Plan to determine whether the introduction of PACS at 10 hospitals in the Thames Valley region of southwestern Ontario, Canada between June 2004 and December 2005 reduced the frequency of duplicate imaging examinations. The imaging modalities studied were: chest and abdominal X-ray; computed tomography of the abdomen/pelvis, head, and chest. The frequency of duplicate testing was examined at 3 different time frames: 7 days, 30 days, and 60 days after a given index test.</p> <p>Results</p> <p>Overall frequencies of duplicate imaging were: 2.7% within 7 days of an index imaging test, 6.7% within 30 days, and 9.8% within 60 days. Comparing the 12 months before and 12 months after PACS, absolute reductions in the frequency of duplicate X-rays using 7-day, 30-day, and 60-day time frames were: 0.2% (P = 0.01), 0.6% (P < 0.001), and 0.9% (P < 0.001), respectively. In contrast, there were absolute <it>increases </it>in the frequency of duplicate CT scans after PACS of 0.0% (P = 0.92), 0.5% (P = 0.01), and 0.5% (P = 0.01), respectively.</p> <p>Conclusion</p> <p>The frequency of duplicate imaging is relatively low and we did not find large reductions in duplicate imaging after the introduction of PACS. Independent evaluation of electronic medical systems should be conducted to confirm widely held beliefs of their potential benefits.</p

    Anisotropic Impurity-States, Quasiparticle Scattering and Nematic Transport in Underdoped Ca(Fe1-xCox)2As2

    Get PDF
    Iron-based high temperature superconductivity develops when the `parent' antiferromagnetic/orthorhombic phase is suppressed, typically by introduction of dopant atoms. But their impact on atomic-scale electronic structure, while in theory quite complex, is unknown experimentally. What is known is that a strong transport anisotropy with its resistivity maximum along the crystal b-axis, develops with increasing concentration of dopant atoms; this `nematicity' vanishes when the `parent' phase disappears near the maximum superconducting Tc. The interplay between the electronic structure surrounding each dopant atom, quasiparticle scattering therefrom, and the transport nematicity has therefore become a pivotal focus of research into these materials. Here, by directly visualizing the atomic-scale electronic structure, we show that substituting Co for Fe atoms in underdoped Ca(Fe1-xCox)2As2 generates a dense population of identical anisotropic impurity states. Each is ~8 Fe-Fe unit cells in length, and all are distributed randomly but aligned with the antiferromagnetic a-axis. By imaging their surrounding interference patterns, we further demonstrate that these impurity states scatter quasiparticles in a highly anisotropic manner, with the maximum scattering rate concentrated along the b-axis. These data provide direct support for the recent proposals that it is primarily anisotropic scattering by dopant-induced impurity states that generates the transport nematicity; they also yield simple explanations for the enhancement of the nematicity proportional to the dopant density and for the occurrence of the highest resistivity along the b-axis

    Aspects of electron-phonon interactions with strong forward scattering in FeSe Thin Films on SrTiO3_3 substrates

    Full text link
    Mono- and multilayer FeSe thin films grown on SrTiO3_\mathrm{3} and BiTiO3_\mathrm{3} substrates exhibit a greatly enhanced superconductivity over that found in bulk FeSe. A number of proposals have been advanced for the mechanism of this enhancement. One possibility is the introduction of a cross-interface electron-phonon (ee-phph) interaction between the FeSe electrons and oxygen phonons in the substrates that is peaked in the forward scattering (small q{\bf q}) direction due to the two-dimensional nature of the interface system. Motivated by this, we explore the consequences of such an interaction on the superconducting state and electronic structure of a two-dimensional system using Migdal-Eliashberg theory. This interaction produces not only deviations from the expectations of conventional phonon-mediated pairing but also replica structures in the spectral function and density of states, as probed by angle-resolved photoemission spectroscopy, scanning tunneling microscopy/spectroscopy, and quasi-particle interference imaging. We also discuss the applicability of Migdal-Eliashberg theory for a situation where the \ep interaction is peaked at small momentum transfer and in the FeSe/STO system

    Does improved access to diagnostic imaging results reduce hospital length of stay? A retrospective study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>One year after the introduction of Information and Communication Technology (ICT) to support diagnostic imaging at our hospital, clinicians had faster and better access to radiology reports and images; direct access to Computed Tomography (CT) reports in the Electronic Medical Record (EMR) was particularly popular. The objective of this study was to determine whether improvements in radiology reporting and clinical access to diagnostic imaging information one year after the ICT introduction were associated with a reduction in the length of patients' hospital stays (LOS).</p> <p>Methods</p> <p>Data describing hospital stays and diagnostic imaging were collected retrospectively from the EMR during periods of equal duration before and one year after the introduction of ICT. The post-ICT period was chosen because of the documented improvement in clinical access to radiology results during that period. The data set was randomly split into an exploratory part used to establish the hypotheses, and a confirmatory part. The data was used to compare the pre-ICT and post-ICT status, but also to compare differences between groups.</p> <p>Results</p> <p>There was no general reduction in LOS one year after ICT introduction. However, there was a 25% reduction for one group - patients with CT scans. This group was heterogeneous, covering 445 different primary discharge diagnoses. Analyses of subgroups were performed to reduce the impact of this divergence.</p> <p>Conclusion</p> <p>Our results did not indicate that improved access to radiology results reduced the patients' LOS. There was, however, a significant reduction in LOS for patients undergoing CT scans. Given the clinicians' interest in CT reports and the results of the subgroup analyses, it is likely that improved access to CT reports contributed to this reduction.</p

    Single-shot compressed ultrafast photography at one hundred billion frames per second

    Get PDF
    The capture of transient scenes at high imaging speed has been long sought by photographers, with early examples being the well known recording in 1878 of a horse in motion and the 1887 photograph of a supersonic bullet. However, not until the late twentieth century were breakthroughs achieved in demonstrating ultrahigh-speed imaging (more than 10^5 frames per second). In particular, the introduction of electronic imaging sensors based on the charge-coupled device (CCD) or complementary metal–oxide–semiconductor (CMOS) technology revolutionized high-speed photography, enabling acquisition rates of up to 10^7 frames per second. Despite these sensors’ widespread impact, further increasing frame rates using CCD or CMOS technology is fundamentally limited by their on-chip storage and electronic readout speed. Here we demonstrate a two-dimensional dynamic imaging technique, compressed ultrafast photography (CUP), which can capture non-repetitive time-evolving events at up to 10^(11) frames per second. Compared with existing ultrafast imaging techniques, CUP has the prominent advantage of measuring an x–y–t (x, y, spatial coordinates; t, time) scene with a single camera snapshot, thereby allowing observation of transient events with temporal resolution as tens of picoseconds. Furthermore, akin to traditional photography, CUP is receive-only, and so does not need the specialized active illumination required by other single-shot ultrafast imagers. As a result, CUP can image a variety of luminescent—such as fluorescent or bioluminescent—objects. Using CUP, we visualize four fundamental physical phenomena with single laser shots only: laser pulse reflection and refraction, photon racing in two media, and faster-than-light propagation of non-information (that is, motion that appears faster than the speed of light but cannot convey information). Given CUP’s capability, we expect it to find widespread applications in both fundamental and applied sciences, including biomedical research

    Image Sharing Technologies and Reduction of Imaging Utilization: A Systematic Review and Meta-analysis

    Get PDF
    INTRODUCTION: Image sharing technologies may reduce unneeded imaging by improving provider access to imaging information. A systematic review and meta-analysis were conducted to summarize the impact of image sharing technologies on patient imaging utilization. METHODS: Quantitative evaluations of the effects of PACS, regional image exchange networks, interoperable electronic heath records, tools for importing physical media, and health information exchange systems on utilization were identified through a systematic review of the published and gray English-language literature (2004-2014). Outcomes, standard effect sizes (ESs), settings, technology, populations, and risk of bias were abstracted from each study. The impact of image sharing technologies was summarized with random-effects meta-analysis and meta-regression models. RESULTS: A total of 17 articles were included in the review, with a total of 42 different studies. Image sharing technology was associated with a significant decrease in repeat imaging (pooled effect size [ES] = -0.17; 95% confidence interval [CI] = [-0.25, -0.09]; P < .001). However, image sharing technology was associated with a significant increase in any imaging utilization (pooled ES = 0.20; 95% CI = [0.07, 0.32]; P = .002). For all outcomes combined, image sharing technology was not associated with utilization. Most studies were at risk for bias. CONCLUSIONS: Image sharing technology was associated with reductions in repeat and unnecessary imaging, in both the overall literature and the most-rigorous studies. Stronger evidence is needed to further explore the role of specific technologies and their potential impact on various modalities, patient populations, and settings
    corecore