8,250 research outputs found
On-line transformer condition monitoring through diagnostics and anomaly detection
This paper describes the end-to-end components of an on-line system for diagnostics and anomaly detection. The system provides condition monitoring capabilities for two in- service transmission transformers in the UK. These transformers are nearing the end of their design life, and it is hoped that intensive monitoring will enable them to stay in service for longer. The paper discusses the requirements on a system for interpreting data from the sensors installed on site, as well as describing the operation of specific diagnostic and anomaly detection techniques employed. The system is deployed on a substation computer, collecting and interpreting site data on-line
Technical and vocational skills (TVS): a means of preventing violence among youth in Nigeria
Technical and vocational skills are an important tool for reducing violence among youth, especially in Nigeria, who face security challenges due to different kinds of violence. This paper focusses on the policies and programmes intended to provide youth with skills that can help them improve their life instead of engaging in violence. The paper also studies youth participation in violence. The study shows that youth in Nigeria participate in violence because of unemployment and economic pressure. These youth are mostly from poor families and are mostly used by others to achieve their own unlawful ambition. The data were collected from various secondary sources such as textbooks, journals and conference papers that were carefully reviewed. The results obtained from the literature revealed that youth are not committed, sensitised and mobilised to taking advantage of the opportunities available to them. The results also revealed that almost all the programmes meant to provide youths with skills have failed. Poverty alleviation programmes established to create jobs, self-employment and self-reliance have been unsuccessful. Therefore, alternatives must be provided to help the younger generations. Based on the literature reviewed, the paper discusses related issues and outcomes and ends with recommendations to improve the situation
Time domain analysis of switching transient fields in high voltage substations
Switching operations of circuit breakers and disconnect switches generate transient currents propagating along the substation busbars. At the moment of switching, the busbars temporarily acts as antennae radiating transient electromagnetic fields within the substations. The radiated fields may interfere and disrupt normal operations of electronic equipment used within the substation for measurement, control and communication purposes. Hence there is the need to fully characterise the substation electromagnetic environment as early as the design stage of substation planning and operation to ensure safe operations of the electronic equipment. This paper deals with the computation of transient electromagnetic fields due to switching within a high voltage air-insulated substation (AIS) using the finite difference time domain (FDTD) metho
A frequency-based RF partial discharge detector for low-power wireless sensing
Partial discharge (PD) monitoring has been the subject of significant research in recent years, which has given rise to a range of well-established PD detection and measurement techniques, such as acoustic and RF, on which condition monitoring systems for highvoltage equipment have been based. This paper presents a novel approach to partial discharge monitoring by using a low-cost, low-power RF detector. The detector employs a frequency-based technique that can distinguish between multiple partial discharge events and other impulsive noise sources within a substation, tracking defect severity over time and providing information pertaining to plant health. The detector is designed to operate as part of a wireless condition monitoring network, removing the need for additional wiring to be installed into substations whilst still gaining the benefits of the RF technique. This novel approach to PD detection not only provides a low-cost solution to on-line partial discharge monitoring, but also presents a means to deploy wide-scale RF monitoring without the associated costs of wide-band monitoring systems
UHF diagnostic monitoring techniques for power transformers
This paper initially gives an introduction to ultra-high frequency (UHF) partial discharge monitoring techniques and their application to gas insulated substations. Recent advances in the technique, covering its application to power transformers, are then discussed and illustrated by means of four site trials. Mounting and installation of the UHF sensors is described and measurements of electrical discharges inside transformers are presented in a range of formats, demonstrating the potential of the UHF method. A procedure for locating sources of electrical discharge is described and demonstrated by means of a practical example where a source of sparking on a tap changer lead was located to within 15 cm. Progress with the development of a prototype on-line monitoring and diagnostic system is reviewed and possible approaches to its utilization are discussed. New concepts for enhancing the capabilities of the UHF technique are presented, including the possibility of monitoring the internal mechanical integrity of plant. The research presented provides sufficient evidence to justify the installation of robust UHF sensors on transformer tanks to facilitate their monitoring if and when required during the service lifetime
Monitoring and Fault Location Sensor Network for Underground Distribution Lines
One of the fundamental tasks of electric distribution utilities is guaranteeing a continuous
supply of electricity to their customers. The primary distribution network is a critical part of these
facilities because a fault in it could affect thousands of customers. However, the complexity of
this network has been increased with the irruption of distributed generation, typical in a Smart
Grid and which has significantly complicated some of the analyses, making it impossible to apply
traditional techniques. This problem is intensified in underground lines where access is limited. As a
possible solution, this paper proposes to make a deployment of a distributed sensor network along
the power lines. This network proposes taking advantage of its distributed character to support new
approaches of these analyses. In this sense, this paper describes the aquiculture of the proposed
network (adapted to the power grid) based on nodes that use power line communication and energy
harvesting techniques. In this sense, it also describes the implementation of a real prototype that
has been used in some experiments to validate this technological adaptation. Additionally, beyond
a simple use for monitoring, this paper also proposes the use of this approach to solve two typical
distribution system operator problems, such as: fault location and failure forecasting in power cables.Ministerio de EconomĂa y Competitividad, Government of Spain project Sistema Inteligente InalĂĄmbrico para AnĂĄlisis y MonitorizaciĂłn de LĂneas de TensiĂłn SubterrĂĄneas en Smart Grids (SIIAM) TEC2013-40767-RMinisterio de EducaciĂłn, Cultura y Deporte, Government of Spain, for the funding of the scholarship FormaciĂłn de Profesorado Universitario 2016 (FPU 2016
Learning models of plant behavior for anomaly detection and condition monitoring
Providing engineers and asset managers with a too] which can diagnose faults within transformers can greatly assist decision making on such issues as maintenance, performance and safety. However, the onus has always been on personnel to accurately decide how serious a problem is and how urgently maintenance is required. In dealing with the large volumes of data involved, it is possible that faults may not be noticed until serious damage has occurred. This paper proposes the integration of a newly developed anomaly detection technique with an existing diagnosis system. By learning a Hidden Markov Model of healthy transformer behavior, unexpected operation, such as when a fault develops, can be flagged for attention. Faults can then be diagnosed using the existing system and maintenance scheduled as required, all at a much earlier stage than would previously have been possible
Impact Assessment of Hypothesized Cyberattacks on Interconnected Bulk Power Systems
The first-ever Ukraine cyberattack on power grid has proven its devastation
by hacking into their critical cyber assets. With administrative privileges
accessing substation networks/local control centers, one intelligent way of
coordinated cyberattacks is to execute a series of disruptive switching
executions on multiple substations using compromised supervisory control and
data acquisition (SCADA) systems. These actions can cause significant impacts
to an interconnected power grid. Unlike the previous power blackouts, such
high-impact initiating events can aggravate operating conditions, initiating
instability that may lead to system-wide cascading failure. A systemic
evaluation of "nightmare" scenarios is highly desirable for asset owners to
manage and prioritize the maintenance and investment in protecting their
cyberinfrastructure. This survey paper is a conceptual expansion of real-time
monitoring, anomaly detection, impact analyses, and mitigation (RAIM) framework
that emphasizes on the resulting impacts, both on steady-state and dynamic
aspects of power system stability. Hypothetically, we associate the
combinatorial analyses of steady state on substations/components outages and
dynamics of the sequential switching orders as part of the permutation. The
expanded framework includes (1) critical/noncritical combination verification,
(2) cascade confirmation, and (3) combination re-evaluation. This paper ends
with a discussion of the open issues for metrics and future design pertaining
the impact quantification of cyber-related contingencies
- âŠ