82 research outputs found

    The Evolution of Data Fusion Methodologies Developed to Reconstruct Coronary Artery Geometry From Intravascular Imaging and Coronary Angiography Data: A Comprehensive Review

    Get PDF
    Understanding the mechanisms that regulate atherosclerotic plaque formation and evolution is a crucial step for developing treatment strategies that will prevent plaque progression and reduce cardiovascular events. Advances in signal processing and the miniaturization of medical devices have enabled the design of multimodality intravascular imaging catheters that allow complete and detailed assessment of plaque morphology and biology. However, a significant limitation of these novel imaging catheters is that they provide two-dimensional (2D) visualization of the lumen and vessel wall and thus they cannot portray vessel geometry and 3D lesion architecture. To address this limitation computer-based methodologies and user-friendly software have been developed. These are able to off-line process and fuse intravascular imaging data with X-ray or computed tomography coronary angiography (CTCA) to reconstruct coronary artery anatomy. The aim of this review article is to summarize the evolution in the field of coronary artery modeling; we thus present the first methodologies that were developed to model vessel geometry, highlight the modifications introduced in revised methods to overcome the limitations of the first approaches and discuss the challenges that need to be addressed, so these techniques can have broad application in clinical practice and research

    Relation between plaque type, plaque thickness, blood shear stress, and plaque stress in coronary arteries assessed by X-ray Angiography and Intravascular Ultrasound

    Get PDF
    Purpose: Atheromatic plaque progression is affected, among others phenomena, by biomechanical, biochemical, and physiological factors. In this paper, the authors introduce a novel framework able to provide both morphological (vessel radius, plaque thickness, and type) and biomechanical (wall shear stress and Von Mises stress) indices of coronary arteries. Methods: First, the approach reconstructs the three-dimensional morphology of the vessel from intravascular ultrasound(IVUS) and Angiographic sequences, requiring minimal user interaction. Then, a computational pipeline allows to automatically assess fluid-dynamic and mechanical indices. Ten coronary arteries are analyzed illustrating the capabilities of the tool and confirming previous technical and clinical observations. Results: The relations between the arterial indices obtained by IVUS measurement and simulations have been quantitatively analyzed along the whole surface of the artery, extending the analysis of the coronary arteries shown in previous state of the art studies. Additionally, for the first time in the literature, the framework allows the computation of the membrane stresses using a simplified mechanical model of the arterial wall. Conclusions: Circumferentially (within a given frame), statistical analysis shows an inverse relation between the wall shear stress and the plaque thickness. At the global level (comparing a frame within the entire vessel), it is observed that heavy plaque accumulations are in general calcified and are located in the areas of the vessel having high wall shear stress. Finally, in their experiments the inverse proportionality between fluid and structural stresses is observed

    The evolution of data fusion methodologies developed to reconstruct coronary artery geometry from intravascular imaging and coronary angiography data: a comprehensive review

    Get PDF
    Understanding the mechanisms that regulate atherosclerotic plaque formation and evolution is a crucial step for developing treatment strategies that will prevent plaque progression and reduce cardiovascular events. Advances in signal processing and the miniaturization of medical devices have enabled the design of multimodality intravascular imaging catheters that allow complete and detailed assessment of plaque morphology and biology. However, a significant limitation of these novel imaging catheters is that they provide two-dimensional (2D) visualization of the lumen and vessel wall and thus they cannot portray vessel geometry and 3D lesion architecture. To address this limitation computer-based methodologies and user-friendly software have been developed. These are able to off-line process and fuse intravascular imaging data with X-ray or computed tomography coronary angiography (CTCA) to reconstruct coronary artery anatomy. The aim of this review article is to summarize the evolution in the field of coronary artery modeling; we thus present the first methodologies that were developed to model vessel geometry, highlight the modifications introduced in revised methods to overcome the limitations of the first approaches and discuss the challenges that need to be addressed, so these techniques can have broad application in clinical practice and research.Cardiovascular Aspects of Radiolog

    Augmented Reality in Minimally Invasive Surgery

    Get PDF
    In the last 15 years Minimally Invasive Surgery, with techniques such as laparoscopy or endoscopy, has become very important and research in this field is increasing since these techniques provide the surgeons with less invasive means of reaching the patient’s internal anatomy and allow for entire procedures to be performed with only minimal trauma to the patient. The advantages of the use of this surgical method are evident for patients because the possible trauma is reduced, postoperative recovery is generally faster and there is less scarring. Despite the improvement in outcomes, indirect access to the operation area causes restricted vision, difficulty in hand-eye coordination, limited mobility handling instruments, two-dimensional imagery with a lack of detailed information and a limited visual field during the whole operation. The use of the emerging Augmented Reality technology shows the way forward by bringing the advantages of direct visualization (which you have in open surgery) back to minimally invasive surgery and increasing the physician's view of his surroundings with information gathered from patient medical images. Augmented Reality can avoid some drawbacks of Minimally Invasive Surgery and can provide opportunities for new medical treatments. After two decades of research into medical Augmented Reality, this technology is now advanced enough to meet the basic requirements for a large number of medical applications and it is feasible that medical AR applications will be accepted by physicians in order to evaluate their use and integration into the clinical workflow. Before seeing the systematic use of these technologies as support for minimally invasive surgery some improvements are still necessary in order to fully satisfy the requirements of operating physicians

    Recent Progress in Transformer-based Medical Image Analysis

    Full text link
    The transformer is primarily used in the field of natural language processing. Recently, it has been adopted and shows promise in the computer vision (CV) field. Medical image analysis (MIA), as a critical branch of CV, also greatly benefits from this state-of-the-art technique. In this review, we first recap the core component of the transformer, the attention mechanism, and the detailed structures of the transformer. After that, we depict the recent progress of the transformer in the field of MIA. We organize the applications in a sequence of different tasks, including classification, segmentation, captioning, registration, detection, enhancement, localization, and synthesis. The mainstream classification and segmentation tasks are further divided into eleven medical image modalities. A large number of experiments studied in this review illustrate that the transformer-based method outperforms existing methods through comparisons with multiple evaluation metrics. Finally, we discuss the open challenges and future opportunities in this field. This task-modality review with the latest contents, detailed information, and comprehensive comparison may greatly benefit the broad MIA community.Comment: Computers in Biology and Medicine Accepte

    INTERFACE DESIGN FOR A VIRTUAL REALITY-ENHANCED IMAGE-GUIDED SURGERY PLATFORM USING SURGEON-CONTROLLED VIEWING TECHNIQUES

    Get PDF
    Initiative has been taken to develop a VR-guided cardiac interface that will display and deliver information without affecting the surgeons’ natural workflow while yielding better accuracy and task completion time than the existing setup. This paper discusses the design process, the development of comparable user interface prototypes as well as an evaluation methodology that can measure user performance and workload for each of the suggested display concepts. User-based studies and expert recommendations are used in conjunction to es­ tablish design guidelines for our VR-guided surgical platform. As a result, a better understanding of autonomous view control, depth display, and use of virtual context, is attained. In addition, three proposed interfaces have been developed to allow a surgeon to control the view of the virtual environment intra-operatively. Comparative evaluation of the three implemented interface prototypes in a simulated surgical task scenario, revealed performance advantages for stereoscopic and monoscopic biplanar display conditions, as well as the differences between three types of control modalities. One particular interface prototype demonstrated significant improvement in task performance. Design recommendations are made for this interface as well as the others as we prepare for prospective development iterations

    XXII International Conference on Mechanics in Medicine and Biology - Abstracts Book

    Get PDF
    This book contain the abstracts presented the XXII ICMMB, held in Bologna in September 2022. The abstracts are divided following the sessions scheduled during the conference

    Ultrasound Imaging

    Get PDF
    This book provides an overview of ultrafast ultrasound imaging, 3D high-quality ultrasonic imaging, correction of phase aberrations in medical ultrasound images, etc. Several interesting medical and clinical applications areas are also discussed in the book, like the use of three dimensional ultrasound imaging in evaluation of Asherman's syndrome, the role of 3D ultrasound in assessment of endometrial receptivity and follicular vascularity to predict the quality oocyte, ultrasound imaging in vascular diseases and the fetal palate, clinical application of ultrasound molecular imaging, Doppler abdominal ultrasound in small animals and so on

    Specular reflection removal and bloodless vessel segmentation for 3-D heart model reconstruction from single view images

    Get PDF
    Three Dimensional (3D) human heart model is attracting attention for its role in medical images for education and clinical purposes. Analysing 2D images to obtain meaningful information requires a certain level of expertise. Moreover, it is time consuming and requires special devices to obtain aforementioned images. In contrary, a 3D model conveys much more information. 3D human heart model reconstruction from medical imaging devices requires several input images, while reconstruction from a single view image is challenging due to the colour property of the heart image, light reflections, and its featureless surface. Lights and illumination condition of the operating room cause specular reflections on the wet heart surface that result in noises forming of the reconstruction process. Image-based technique is used for the proposed human heart surface reconstruction. It is important the reflection is eliminated to allow for proper 3D reconstruction and avoid imperfect final output. Specular reflections detection and correction process examine the surface properties. This was implemented as a first step to detect reflections using the standard deviation of RGB colour channel and the maximum value of blue channel to establish colour, devoid of specularities. The result shows the accurate and efficient performance of the specularities removing process with 88.7% similarity with the ground truth. Realistic 3D heart model reconstruction was developed based on extraction of pixel information from digital images to allow novice surgeons to reduce the time for cardiac surgery training and enhancing their perception of the Operating Theatre (OT). Cardiac medical imaging devices such as Magnetic Resonance Imaging (MRI), Computed Tomography (CT) images, or Echocardiography provide cardiac information. However,these images from medical modalities are not adequate, to precisely simulate the real environment and to be used in the training simulator for cardiac surgery. The propose method exploits and develops techniques based on analysing real coloured images taken during cardiac surgery in order to obtain meaningful information of the heart anatomical structures. Another issue is the different human heart surface vessels. The most important vessel region is the bloodless, lack of blood, vessels. Surgeon faces some difficulties in locating the bloodless vessel region during surgery. The thesis suggests a technique of identifying the vessels’ Region of Interest (ROI) to avoid surgical injuries by examining an enhanced input image. The proposed method locates vessels’ ROI by using Decorrelation Stretch technique. This Decorrelation Stretch can clearly enhance the heart’s surface image. Through this enhancement, the surgeon become enables effectively identifying the vessels ROI to perform the surgery from textured and coloured surface images. In addition, after enhancement and segmentation of the vessels ROI, a 3D reconstruction of this ROI takes place and then visualize it over the 3D heart model. Experiments for each phase in the research framework were qualitatively and quantitatively evaluated. Two hundred and thirteen real human heart images are the dataset collected during cardiac surgery using a digital camera. The experimental results of the proposed methods were compared with manual hand-labelling ground truth data. The cost reduction of false positive and false negative of specular detection and correction processes of the proposed method was less than 24% compared to other methods. In addition, the efficient results of Root Mean Square Error (RMSE) to measure the correctness of the z-axis values to reconstruction of the 3D model accurately compared to other method. Finally, the 94.42% accuracy rate of the proposed vessels segmentation method using RGB colour space achieved is comparable to other colour spaces. Experimental results show that there is significant efficiency and robustness compared to existing state of the art methods