33 research outputs found
Computational methods for the analysis of functional 4D-CT chest images.
Medical imaging is an important emerging technology that has been intensively used in the last few decades for disease diagnosis and monitoring as well as for the assessment of treatment effectiveness. Medical images provide a very large amount of valuable information that is too huge to be exploited by radiologists and physicians. Therefore, the design of computer-aided diagnostic (CAD) system, which can be used as an assistive tool for the medical community, is of a great importance. This dissertation deals with the development of a complete CAD system for lung cancer patients, which remains the leading cause of cancer-related death in the USA. In 2014, there were approximately 224,210 new cases of lung cancer and 159,260 related deaths. The process begins with the detection of lung cancer which is detected through the diagnosis of lung nodules (a manifestation of lung cancer). These nodules are approximately spherical regions of primarily high density tissue that are visible in computed tomography (CT) images of the lung. The treatment of these lung cancer nodules is complex, nearly 70% of lung cancer patients require radiation therapy as part of their treatment. Radiation-induced lung injury is a limiting toxicity that may decrease cure rates and increase morbidity and mortality treatment. By finding ways to accurately detect, at early stage, and hence prevent lung injury, it will have significant positive consequences for lung cancer patients. The ultimate goal of this dissertation is to develop a clinically usable CAD system that can improve the sensitivity and specificity of early detection of radiation-induced lung injury based on the hypotheses that radiated lung tissues may get affected and suffer decrease of their functionality as a side effect of radiation therapy treatment. These hypotheses have been validated by demonstrating that automatic segmentation of the lung regions and registration of consecutive respiratory phases to estimate their elasticity, ventilation, and texture features to provide discriminatory descriptors that can be used for early detection of radiation-induced lung injury. The proposed methodologies will lead to novel indexes for distinguishing normal/healthy and injured lung tissues in clinical decision-making. To achieve this goal, a CAD system for accurate detection of radiation-induced lung injury that requires three basic components has been developed. These components are the lung fields segmentation, lung registration, and features extraction and tissue classification. This dissertation starts with an exploration of the available medical imaging modalities to present the importance of medical imaging in today’s clinical applications. Secondly, the methodologies, challenges, and limitations of recent CAD systems for lung cancer detection are covered. This is followed by introducing an accurate segmentation methodology of the lung parenchyma with the focus of pathological lungs to extract the volume of interest (VOI) to be analyzed for potential existence of lung injuries stemmed from the radiation therapy. After the segmentation of the VOI, a lung registration framework is introduced to perform a crucial and important step that ensures the co-alignment of the intra-patient scans. This step eliminates the effects of orientation differences, motion, breathing, heart beats, and differences in scanning parameters to be able to accurately extract the functionality features for the lung fields. The developed registration framework also helps in the evaluation and gated control of the radiotherapy through the motion estimation analysis before and after the therapy dose. Finally, the radiation-induced lung injury is introduced, which combines the previous two medical image processing and analysis steps with the features estimation and classification step. This framework estimates and combines both texture and functional features. The texture features are modeled using the novel 7th-order Markov Gibbs random field (MGRF) model that has the ability to accurately models the texture of healthy and injured lung tissues through simultaneously accounting for both vertical and horizontal relative dependencies between voxel-wise signals. While the functionality features calculations are based on the calculated deformation fields, obtained from the 4D-CT lung registration, that maps lung voxels between successive CT scans in the respiratory cycle. These functionality features describe the ventilation, the air flow rate, of the lung tissues using the Jacobian of the deformation field and the tissues’ elasticity using the strain components calculated from the gradient of the deformation field. Finally, these features are combined in the classification model to detect the injured parts of the lung at an early stage and enables an earlier intervention
Segmentation, tracking, and kinematics of lung parenchyma and lung tumors from 4D CT with application to radiation treatment planning.
This thesis is concerned with development of techniques for efficient computerized analysis of 4-D CT data. The goal is to have a highly automated approach to segmentation of the lung boundary and lung nodules inside the lung. The determination of exact lung tumor location over space and time by image segmentation is an essential step to track thoracic malignancies. Accurate image segmentation helps clinical experts examine the anatomy and structure and determine the disease progress. Since 4-D CT provides structural and anatomical information during tidal breathing, we use the same data to also measure mechanical properties related to deformation of the lung tissue including Jacobian and strain at high resolutions and as a function of time. Radiation Treatment of patients with lung cancer can benefit from knowledge of these measures of regional ventilation. Graph-cuts techniques have been popular for image segmentation since they are able to treat highly textured data via robust global optimization, avoiding local minima in graph based optimization. The graph-cuts methods have been used to extract globally optimal boundaries from images by s/t cut, with energy function based on model-specific visual cues, and useful topological constraints. The method makes N-dimensional globally optimal segmentation possible with good computational efficiency. Even though the graph-cuts method can extract objects where there is a clear intensity difference, segmentation of organs or tumors pose a challenge. For organ segmentation, many segmentation methods using a shape prior have been proposed. However, in the case of lung tumors, the shape varies from patient to patient, and with location. In this thesis, we use a shape prior for tumors through a training step and PCA analysis based on the Active Shape Model (ASM). The method has been tested on real patient data from the Brown Cancer Center at the University of Louisville. We performed temporal B-spline deformable registration of the 4-D CT data - this yielded 3-D deformation fields between successive respiratory phases from which measures of regional lung function were determined. During the respiratory cycle, the lung volume changes and five different lobes of the lung (two in the left and three in the right lung) show different deformation yielding different strain and Jacobian maps. In this thesis, we determine the regional lung mechanics in the Lagrangian frame of reference through different respiratory phases, for example, Phase10 to 20, Phase10 to 30, Phase10 to 40, and Phase10 to 50. Single photon emission computed tomography (SPECT) lung imaging using radioactive tracers with SPECT ventilation and SPECT perfusion imaging also provides functional information. As part of an IRB-approved study therefore, we registered the max-inhale CT volume to both VSPECT and QSPECT data sets using the Demon\u27s non-rigid registration algorithm in patient subjects. Subsequently, statistical correlation between CT ventilation images (Jacobian and strain values), with both VSPECT and QSPECT was undertaken. Through statistical analysis with the Spearman\u27s rank correlation coefficient, we found that Jacobian values have the highest correlation with both VSPECT and QSPECT
Zeitabhängige, multimodale Modellierung und Analyse von Herzdaten
Kardiovaskuläre Erkrankungen stellen in den westlichen Industrienationen eine der Haupttodesursachen dar. Für die Diagnostik steht inzwischen mit der Computer-Tomographie ein leistungsfähiges bildgebendes Verfahren zur Verfügung.
Im Rahmen dieser Arbeit wurden Verfahren entwickelt, um dem Radiologen durch eine weitgehend automatische und umfassende Analyse von 4D-CTA-Daten und der automatischen Berechnung wichtiger diagnostischer Parameter zu unterstützen
Coupled Shape Models for the Diagnosis of Organ Motion Restriction
Annähernd 30% der weltweiten Todesfälle sind auf Erkrankungen des Herzens und der Lunge zurückzuführen, wobei die meisten dieser Erkrankungen während ihres Verlaufs die Mobilität des betroffenen Organs verändern. Viele dieser To-desfälle könnten durch eine frühzeitige Erkennung und Behandlung der Erkran-kung vermieden werden. Deshalb wurden im Zuge dieser Arbeit Methoden ent-wickelt, um aus Segmentierungen von dynamischen Magnetresonanztomogra-phie-Daten quantitative Kennzahlen für die funktionale Analyse der Herz- und Lungenbewegung zu generieren. Ein automatisiertes Segmentierungsverfahren basierend auf gekoppelten Formmodellen wurde entwickelt, welches wechsel-seitige Informationen der Form und Geometrie mehrerer korrelierter Objekte mit einbezieht, und somit 40% bessere Ergebnisse im Vergleich zur Verwendung einzelner Modelle erzielte. Im Fall des Herzens wurde ein Volumenberechnungs-fehler von unter 13% erreicht, was in der Größenordnung der Interobserver-Variabilität liegt. Für die Lunge konnte ein Volumenfehler von unter 70ml gezeigt werden. Aus den Segmentierungsergebnissen wurden funktionale Parameter der lokalen Organdynamik abgeleitet und visualisiert, die gegen konventionelle Diag-nosemethoden evaluiert wurden und dabei gute Übereinstimmung zeigen, dar-über hinaus jedoch eine lokal und regionale Mobilitätscharakterisierung erlau-ben
Rapid Segmentation Techniques for Cardiac and Neuroimage Analysis
Recent technological advances in medical imaging have allowed for the quick acquisition of highly resolved data to aid in diagnosis and characterization of diseases or to guide interventions. In order to to be integrated into a clinical work flow, accurate and robust methods of analysis must be developed which manage this increase in data. Recent improvements in in- expensive commercially available graphics hardware and General-Purpose Programming on Graphics Processing Units (GPGPU) have allowed for many large scale data analysis problems to be addressed in meaningful time and will continue to as parallel computing technology improves. In this thesis we propose methods to tackle two clinically relevant image segmentation problems: a user-guided segmentation of myocardial scar from Late-Enhancement Magnetic Resonance Images (LE-MRI) and a multi-atlas segmentation pipeline to automatically segment and partition brain tissue from multi-channel MRI. Both methods are based on recent advances in computer vision, in particular max-flow optimization that aims at solving the segmentation problem in continuous space. This allows for (approximately) globally optimal solvers to be employed in multi-region segmentation problems, without the particular drawbacks of their discrete counterparts, graph cuts, which typically present with metrication artefacts. Max-flow solvers are generally able to produce robust results, but are known for being computationally expensive, especially with large datasets, such as volume images. Additionally, we propose two new deformable registration methods based on Gauss-Newton optimization and smooth the resulting deformation fields via total-variation regularization to guarantee the problem is mathematically well-posed. We compare the performance of these two methods against four highly ranked and well-known deformable registration methods on four publicly available databases and are able to demonstrate a highly accurate performance with low run times. The best performing variant is subsequently used in a multi-atlas segmentation pipeline for the segmentation of brain tissue and facilitates fast run times for this computationally expensive approach. All proposed methods are implemented using GPGPU for a substantial increase in computational performance and so facilitate deployment into clinical work flows. We evaluate all proposed algorithms in terms of run times, accuracy, repeatability and errors arising from user interactions and we demonstrate that these methods are able to outperform established methods. The presented approaches demonstrate high performance in comparison with established methods in terms of accuracy and repeatability while largely reducing run times due to the employment of GPU hardware
Recommended from our members
Development of computer-based algorithms for unsupervised assessment of radiotherapy contouring
INTRODUCTION: Despite the advances in radiotherapy treatment delivery, target volume
delineation remains one of the greatest sources of error in the radiotherapy delivery process,
which can lead to poor tumour control probability and impact clinical outcome. Contouring
assessments are performed to ensure high quality of target volume definition in clinical trials
but this can be subjective and labour-intensive.
This project addresses the hypothesis that computational segmentation techniques, with a given
prior, can be used to develop an image-based tumour delineation process for contour
assessments. This thesis focuses on the exploration of the segmentation techniques to develop
an automated method for generating reference delineations in the setting of advanced lung
cancer. The novelty of this project is in the use of the initial clinician outline as a prior for
image segmentation.
METHODS: Automated segmentation processes were developed for stage II and III non-small
cell lung cancer using the IDEAL-CRT clinical trial dataset. Marker-controlled watershed
segmentation, two active contour approaches (edge- and region-based) and graph-cut applied
on superpixels were explored. k-nearest neighbour (k-NN) classification of tumour from
normal tissues based on texture features was also investigated.
RESULTS: 63 cases were used for development and training. Segmentation and classification
performance were evaluated on an independent test set of 16 cases. Edge-based active contour
segmentation achieved highest Dice similarity coefficient of 0.80 ± 0.06, followed by graphcut
at 0.76 ± 0.06, watershed at 0.72 ± 0.08 and region-based active contour at 0.71 ± 0.07,
with mean computational times of 192 ± 102 sec, 834 ± 438 sec, 21 ± 5 sec and 45 ± 18 sec
per case respectively. Errors in accuracy of irregularly shaped lesions and segmentation
leakages at the mediastinum were observed.
In the distinction of tumour and non-tumour regions, misclassification errors of 14.5% and
15.5% were achieved using 16- and 8-pixel regions of interest (ROIs) respectively. Higher
misclassification errors of 24.7% and 26.9% for 16- and 8-pixel ROIs were obtained in the
analysis of the tumour boundary.
CONCLUSIONS: Conventional image-based segmentation techniques with the application of
priors are useful in automatic segmentation of tumours, although further developments are
required to improve their performance. Texture classification can be useful in distinguishing
tumour from non-tumour tissue, but the segmentation task at the tumour boundary is more
difficult. Future work with deep-learning segmentation approaches need to be explored.Funded by National Radiotherapy Trials Quality Assurance (RTTQA) grou
Navigation system based in motion tracking sensor for percutaneous renal access
Tese de Doutoramento em Engenharia BiomédicaMinimally-invasive kidney interventions are daily performed to diagnose and treat several renal
diseases. Percutaneous renal access (PRA) is an essential but challenging stage for most of these
procedures, since its outcome is directly linked to the physician’s ability to precisely visualize and
reach the anatomical target.
Nowadays, PRA is always guided with medical imaging assistance, most frequently using X-ray
based imaging (e.g. fluoroscopy). Thus, radiation on the surgical theater represents a major risk to
the medical team, where its exclusion from PRA has a direct impact diminishing the dose exposure
on both patients and physicians.
To solve the referred problems this thesis aims to develop a new hardware/software framework
to intuitively and safely guide the surgeon during PRA planning and puncturing.
In terms of surgical planning, a set of methodologies were developed to increase the certainty of
reaching a specific target inside the kidney. The most relevant abdominal structures for PRA were
automatically clustered into different 3D volumes. For that, primitive volumes were merged as a local
optimization problem using the minimum description length principle and image statistical
properties. A multi-volume Ray Cast method was then used to highlight each segmented volume.
Results show that it is possible to detect all abdominal structures surrounding the kidney, with the
ability to correctly estimate a virtual trajectory.
Concerning the percutaneous puncturing stage, either an electromagnetic or optical solution
were developed and tested in multiple in vitro, in vivo and ex vivo trials. The optical tracking solution
aids in establishing the desired puncture site and choosing the best virtual puncture trajectory.
However, this system required a line of sight to different optical markers placed at the needle base,
limiting the accuracy when tracking inside the human body. Results show that the needle tip can
deflect from its initial straight line trajectory with an error higher than 3 mm. Moreover, a complex
registration procedure and initial setup is needed.
On the other hand, a real-time electromagnetic tracking was developed. Hereto, a catheter
was inserted trans-urethrally towards the renal target. This catheter has a position and orientation
electromagnetic sensor on its tip that function as a real-time target locator. Then, a needle integrating a similar sensor is used. From the data provided by both sensors, one computes a virtual puncture
trajectory, which is displayed in a 3D visualization software. In vivo tests showed a median renal and
ureteral puncture times of 19 and 51 seconds, respectively (range 14 to 45 and 45 to 67 seconds).
Such results represent a puncture time improvement between 75% and 85% when comparing to
state of the art methods.
3D sound and vibrotactile feedback were also developed to provide additional information about
the needle orientation. By using these kind of feedback, it was verified that the surgeon tends to
follow a virtual puncture trajectory with a reduced amount of deviations from the ideal trajectory,
being able to anticipate any movement even without looking to a monitor. Best results show that 3D
sound sources were correctly identified 79.2 ± 8.1% of times with an average angulation error of
10.4º degrees. Vibration sources were accurately identified 91.1 ± 3.6% of times with an average
angulation error of 8.0º degrees.
Additionally to the EMT framework, three circular ultrasound transducers were built with a needle
working channel. One explored different manufacture fabrication setups in terms of the piezoelectric
materials, transducer construction, single vs. multi array configurations, backing and matching
material design. The A-scan signals retrieved from each transducer were filtered and processed to
automatically detect reflected echoes and to alert the surgeon when undesirable anatomical
structures are in between the puncture path. The transducers were mapped in a water tank and
tested in a study involving 45 phantoms. Results showed that the beam cross-sectional area
oscillates around the ceramics radius and it was possible to automatically detect echo signals in
phantoms with length higher than 80 mm.
Hereupon, it is expected that the introduction of the proposed system on the PRA procedure,
will allow to guide the surgeon through the optimal path towards the precise kidney target, increasing
surgeon’s confidence and reducing complications (e.g. organ perforation) during PRA. Moreover, the
developed framework has the potential to make the PRA free of radiation for both patient and surgeon
and to broad the use of PRA to less specialized surgeons.Intervenções renais minimamente invasivas são realizadas diariamente para o tratamento e
diagnóstico de várias doenças renais. O acesso renal percutâneo (ARP) é uma etapa essencial e
desafiante na maior parte destes procedimentos. O seu resultado encontra-se diretamente
relacionado com a capacidade do cirurgião visualizar e atingir com precisão o alvo anatómico.
Hoje em dia, o ARP é sempre guiado com recurso a sistemas imagiológicos, na maior parte
das vezes baseados em raios-X (p.e. a fluoroscopia). A radiação destes sistemas nas salas cirúrgicas
representa um grande risco para a equipa médica, aonde a sua remoção levará a um impacto direto
na diminuição da dose exposta aos pacientes e cirurgiões.
De modo a resolver os problemas existentes, esta tese tem como objetivo o desenvolvimento
de uma framework de hardware/software que permita, de forma intuitiva e segura, guiar o cirurgião
durante o planeamento e punção do ARP.
Em termos de planeamento, foi desenvolvido um conjunto de metodologias de modo a
aumentar a eficácia com que o alvo anatómico é alcançado. As estruturas abdominais mais
relevantes para o procedimento de ARP, foram automaticamente agrupadas em volumes 3D, através
de um problema de optimização global com base no princípio de “minimum description length” e
propriedades estatísticas da imagem. Por fim, um procedimento de Ray Cast, com múltiplas funções
de transferência, foi utilizado para enfatizar as estruturas segmentadas. Os resultados mostram que
é possível detetar todas as estruturas abdominais envolventes ao rim, com a capacidade para
estimar corretamente uma trajetória virtual.
No que diz respeito à fase de punção percutânea, foram testadas duas soluções de deteção
de movimento (ótica e eletromagnética) em múltiplos ensaios in vitro, in vivo e ex vivo. A solução
baseada em sensores óticos ajudou no cálculo do melhor ponto de punção e na definição da melhor
trajetória a seguir. Contudo, este sistema necessita de uma linha de visão com diferentes
marcadores óticos acoplados à base da agulha, limitando a precisão com que a agulha é detetada
no interior do corpo humano. Os resultados indicam que a agulha pode sofrer deflexões à medida
que vai sendo inserida, com erros superiores a 3 mm.
Por outro lado, foi desenvolvida e testada uma solução com base em sensores
eletromagnéticos. Para tal, um cateter que integra um sensor de posição e orientação na sua ponta, foi colocado por via trans-uretral junto do alvo renal. De seguida, uma agulha, integrando um sensor
semelhante, é utilizada para a punção percutânea. A partir da diferença espacial de ambos os
sensores, é possível gerar uma trajetória de punção virtual. A mediana do tempo necessário para
puncionar o rim e ureter, segundo esta trajetória, foi de 19 e 51 segundos, respetivamente
(variações de 14 a 45 e 45 a 67 segundos). Estes resultados representam uma melhoria do tempo
de punção entre 75% e 85%, quando comparados com o estado da arte dos métodos atuais.
Além do feedback visual, som 3D e feedback vibratório foram explorados de modo a fornecer
informações complementares da posição da agulha. Verificou-se que com este tipo de feedback, o
cirurgião tende a seguir uma trajetória de punção com desvios mínimos, sendo igualmente capaz
de antecipar qualquer movimento, mesmo sem olhar para o monitor. Fontes de som e vibração
podem ser corretamente detetadas em 79,2 ± 8,1% e 91,1 ± 3,6%, com erros médios de angulação
de 10.4º e 8.0 graus, respetivamente.
Adicionalmente ao sistema de navegação, foram também produzidos três transdutores de
ultrassom circulares com um canal de trabalho para a agulha. Para tal, foram exploradas diferentes
configurações de fabricação em termos de materiais piezoelétricos, transdutores multi-array ou
singulares e espessura/material de layers de suporte. Os sinais originados em cada transdutor
foram filtrados e processados de modo a detetar de forma automática os ecos refletidos, e assim,
alertar o cirurgião quando existem variações anatómicas ao longo do caminho de punção. Os
transdutores foram mapeados num tanque de água e testados em 45 phantoms. Os resultados
mostraram que o feixe de área em corte transversal oscila em torno do raio de cerâmica, e que os
ecos refletidos são detetados em phantoms com comprimentos superiores a 80 mm.
Desta forma, é expectável que a introdução deste novo sistema a nível do ARP permitirá
conduzir o cirurgião ao longo do caminho de punção ideal, aumentado a confiança do cirurgião e
reduzindo possíveis complicações (p.e. a perfuração dos órgãos). Além disso, de realçar que este
sistema apresenta o potencial de tornar o ARP livre de radiação e alarga-lo a cirurgiões menos
especializados.The present work was only possible thanks to the support by the Portuguese Science and
Technology Foundation through the PhD grant with reference SFRH/BD/74276/2010 funded by
FCT/MEC (PIDDAC) and by Fundo Europeu de Desenvolvimento Regional (FEDER), Programa
COMPETE - Programa Operacional Factores de Competitividade (POFC) do QREN
Atlas-based segmentation of medical images
Atlas-Based Segmentation of medical images is an image analysis task which involves labelling a desired anatomy or set of anatomy from images generated by medical imaging modalities. The overall goal of atlas-based segmentation is to assist radiologists in the detection and diagnosis of diseases. By extracting the relevant anatomy from medical images and presenting it in an appropriate view, their work-flow can be optimised.
This portfolio-style thesis discusses the research projects carried out in order to evaluate the applicability of atlas-based methods to a variety of medical imaging problems. The thesis describes how atlas-based methods have been applied to heart segmentation, to extract the heart for further cardiac analysis from cardiac CT images, to kidney segmentation, to prepare the kidney for automated perfusion measurements, and to coronary vessel tracking, in order to improve on the quality of tracking algorithms.
This thesis demonstrates how state of the art atlas-based segmentation techniques can be applied successfully to a range of clinical problems in different imaging modalities. Each application has been tested using not only standard experimentation principles, but also by clinically-trained personnel to evaluate its efficacy. The success of these methods is such that some of the described applications have since been deployed in commercial products.
While exploring these applications, several techniques based on published literature were explored and tailored to suit each individual application. This thesis describes in detail the methods used for each application in turn, recognising the state of the art, and outlines the author's contribution in every application