12 research outputs found

    Rehabilitation Technologies: Biomechatronics Point of View

    Get PDF

    The development of ergonomics design criteria for powered human movement systems

    Get PDF
    This research developed from a concept for a powered exoskeletal system for manipulating a person's posture to provide them with physical sensations as though taking part in an activity in which they otherwise would not be able to participate. The aim for this research was to develop a set of criteria relating to this physical manipulation, which could be used, in conjunction with visual and audio stimuli, to govern the design of a commercial personal entertainment simulator for use by members of the public. Investigations revealed that there is currently no existing system comparable to this proposed simulator. Therefore, various fields were researched, including robotics, physiotherapy, virtual reality, haptics and existing simulators; with a view to combining elements of these fields for the development of a manipulation system appropriate to public entertainment use. A survey was conducted on members of the public to investigate their experiences of sports, theme park rides and virtual reality; their personalities; and their opinions of the proposed simulator. This survey indicated that the likely users of such a system would be sensation-seeking, physically active people. The activities which generated the most interest were those which were hazardous, difficult, or required long distance travel. To be consistent with these findings, practical trials were undertaken using the sport of skiing as the context for conducting practical investigations into postural manipulation. Existing and original studies of the movements involved in skiing revealed the complexity of this activity, and the variety of techniques employed by different skiers. These findings, combined with the survey data and earlier investigations, led to the development of a versatile prototype system which could accommodate this variability and impose customised skiing movements on volunteers. Volunteer trials using this prototype demonstrated that members of the public were willing to have their postures controlled by external forces, and although some participants were apprehensive at first, they all reported the experience to be enjoyable. Tests with different applied movements showed that users were comfortable with manipulations at speeds and accelerations up to and exceeding those employed in skiing for real. The principal criteria concluded from these trials were that it is possible to safely and comfortably manipulate human postures through external technology, and that this external control can be used to provide an enjoyable and exhilarating entertainment experience.EThOS - Electronic Theses Online ServiceGBUnited Kingdo

    Virtual reality based upper extremity stroke rehabilitation system.

    Get PDF
    Some studies suggest that the use of Virtual Reality technologies as an assistive technology in combination with conventional therapies can achieve improved results in post stroke rehabilitation. Despite the wealth of ongoing research applied to trying to build a virtual reality based system for upper extremity rehabilitation, there still exists a strong need for a training platform that would provide whole arm rehabilitation. In order to be practical such a system should ideally be low cost (affordable or inexpensive for a common individual or household) and involve minimal therapist involvement. This research outlines some of the applications of virtual reality that have undergone clinical trials with patients suffering from upper extremity functional motor deficits. Furthermore, this thesis presents the design, development, implementation and feasibility testing of a Virtual Reality-based Upper Extremity Stroke Rehabilitation System. Motion sensing technology has been used to capture the real time movement data of the upper extremity and a virtual reality glove has been used to track the flexion/extension of the fingers. A virtual room has been designed with an avatar of the human arm to allow a variety of training tasks to be accomplished. An interface has been established to incorporate the real time data from the hardware to a virtual scene running on a PC. Three different training scenes depicting a real world scenario have been designed. These have been used to analyze the motion patterns of the users while executing the tasks in the virtual environment simulation. A usability study with the healthy volunteers performing the training tasks have been undertaken to study the ease of use, ease of learning and improved motivation in the virtual environment. Moreover this system costing approximately 2725 pounds would provide home based rehabilitation of the whole arm augmenting conventional therapy on a positive level. Statistical analysis of the data and the evaluation studies with the self report methodologies suggests the feasibility of the system for post stroke rehabilitation in home environment

    Design and evaluation of a quasi-passive robotic knee brace : on the effects of parallel elasticity on human running

    Get PDF
    Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2012.Cataloged from PDF version of thesis.Includes bibliographical references (p. 103-106).While the effects of series compliance on running biomechanics are documented, the effects of parallel compliance are known only for the simpler case of hopping. As many practical exoskeleton and orthosis designs act in parallel with the leg, it is desirable to understand the effects of such an intervention. Spring-like forces offer a natural choice of perturbation, as they are both biologically motivated and energetically inexpensive to implement. To this end, this thesis investigates the hypothesis that the addition of an external elastic element at the knee during the stance phase of running results in a reduction in knee extensor activation so that total joint quasi-stiffness is maintained. To test this, an exoskeleton is presented, consisting of a leaf spring in parallel with the knee joint and a clutch which engages this spring only during stance. The design of a custom interference clutch, made necessary by the need for high holding torque but low mass, is discussed in detail, as are problems of human attachment. The greater applicability of this clutch design to other problems in rehabilitation and augmentation is also addressed. Motion capture of four subjects is used to investigate the consequences of running with this exoskeleton. Leg stiffness is found to increase with distal mass, but no significant change in leg stiffness or total knee stiffness is observed due to the activation of the clutched parallel knee spring. However, preliminary evidence suggests differing responses between trained marathon runners, who appear to maintain biological knee torque, and recreational runners, who appear to maintain total knee torque. Such a relationship between degree of past training and effective utilization of an external force is suggestive of limitations on the applications of assistive devices.by Grant A. Elliott.Ph.D

    Non-linear actuators and simulation tools for rehabilitation devices

    Get PDF
    Menci贸n Internacional en el t铆tulo de doctorRehabilitation robotics is a field of research that investigates the applications of robotics in motor function therapy for recovering the motor control and motor capability. In general, this type of rehabilitation has been found effective in therapy for persons suffering motor disorders, especially due to stroke or spinal cord injuries. This type of devices generally are well tolerated by the patients also being a motivation in rehabilitation therapy. In the last years the rehabilitation robotics has become more popular, capturing the attention at various research centers. They focused on the development more effective devices in rehabilitation therapy, with a higher acceptance factor of patients tacking into account: the financial cost, weight and comfort of the device. Among the rehabilitation devices, an important category is represented by the rehabilitation exoskeletons, which in addition to the human skeletons help to protect and support the external human body. This became more popular between the rehabilitation devices due to the easily adapting with the dynamics of human body, possibility to use them such as wearable devices and low weight and dimensions which permit easy transportation. Nowadays, in the development of any robotic device the simulation tools play an important role due to their capacity to analyse the expected performance of the system designed prior to manufacture. In the development of the rehabilitation devices, the biomechanical software which is capable to simulate the behaviour interaction between the human body and the robotics devices, play an important role. This helps to choose suitable actuators for the rehabilitation device, to evaluate possible mechanical designs, and to analyse the necessary controls algorithms before being tested in real systems. This thesis presents a research proposing an alternative solution for the current systems of actuation on the exoskeletons for robotic rehabilitation. The proposed solution, has a direct impact, improving issues like device weight, noise, fabrication costs, size an patient comfort. In order to reach the desired results, a biomechanical software based on Biomechanics of Bodies (BoB) simulator where the behaviour of the human body and the rehabilitation device with his actuators can be analysed, was developed. In the context of the main objective of this research, a series of actuators have been analysed, including solutions between the non-linear actuation systems. Between these systems, two solutions have been analysed in detail: ultrasonic motors and Shape Memory Alloy material. Due to the force - weight characteristics of each device (in simulation with the human body), the Shape Memory Alloy material was chosen as principal actuator candidate for rehabilitation devices. The proposed control algorithm for the actuators based on Shape Memory Alloy, was tested over various configurations of actuators design and analysed in terms of energy eficiency, cooling deformation and movement. For the bioinspirated movements, such as the muscular group's biceps-triceps, a control algorithm capable to control two Shape Memory Alloy based actuators in antagonistic movement, has been developed. A segmented exoskeleton based on Shape Memory Alloy actuators for the upper limb evaluation and rehabilitation therapy was proposed to demosntrate the eligibility of the actuation system. This is divided in individual rehabilitation devices for the shoulder, elbow and wrist. The results of this research was tested and validated in the real elbow exoskeleton with two degrees of freedom developed during this thesis.Programa Oficial de Doctorado en Ingenier铆a El茅ctrica, Electr贸nica y Autom谩ticaPresidente: Eduardo Roc贸n de Lima.- Secretario: Concepci贸n Alicia Monje Micharet.- Vocal: Martin Stoele

    Robotics 2010

    Get PDF
    Without a doubt, robotics has made an incredible progress over the last decades. The vision of developing, designing and creating technical systems that help humans to achieve hard and complex tasks, has intelligently led to an incredible variety of solutions. There are barely technical fields that could exhibit more interdisciplinary interconnections like robotics. This fact is generated by highly complex challenges imposed by robotic systems, especially the requirement on intelligent and autonomous operation. This book tries to give an insight into the evolutionary process that takes place in robotics. It provides articles covering a wide range of this exciting area. The progress of technical challenges and concepts may illuminate the relationship between developments that seem to be completely different at first sight. The robotics remains an exciting scientific and engineering field. The community looks optimistically ahead and also looks forward for the future challenges and new development

    Proceedings of the NASA Conference on Space Telerobotics, volume 3

    Get PDF
    The theme of the Conference was man-machine collaboration in space. The Conference provided a forum for researchers and engineers to exchange ideas on the research and development required for application of telerobotics technology to the space systems planned for the 1990s and beyond. The Conference: (1) provided a view of current NASA telerobotic research and development; (2) stimulated technical exchange on man-machine systems, manipulator control, machine sensing, machine intelligence, concurrent computation, and system architectures; and (3) identified important unsolved problems of current interest which can be dealt with by future research

    Aerospace medicine and biology: A continuing bibliography with indexes (supplement 353)

    Get PDF
    This bibliography lists 238 reports, articles, and other documents introduced into the NASA Scientific and Technical Information System in August 1991. Subject coverage includes: aerospace medicine and psychology, life support systems and controlled environments, safety equipment, exobiology and extraterrestrial life, biotechnology, human factors engineering, and flight crew behavior and performance

    Stable, high-force, low-impedance robotic actuators for human-interactive machines

    Get PDF
    Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2005.Includes bibliographical references (p. 347-359).Robots that engage in significant physical interaction with humans, such as robotic physical therapy aids, must exhibit desired mechanical endpoint impedance while simultaneously producing large forces. In most practical robot configurations, this requires actuators with high force-to-weight ratios and low intrinsic impedance. This thesis explores several approaches to improve the tradeoff between actuator force capacity, weight, and ability to produce desired impedance. Existing actuators that render impedance accurately generally have poor force densities while those with high force densities often have high intrinsic impedance. Aggressive force feedback can reduce apparent endpoint impedance, but compromises coupled stability. The common standard for ensuring coupled stability, passivity, can limit performance severely. An alternative measure of coupled stability is proposed that uses limited knowledge of environment dynamics (e.g. a human limb) and applies robust stability tools to port functions. Because of structural differences between interaction control and servo control, classical single-input, single-output control tools cannot be directly applied for design. Instead, a search method is used to select controller parameters for an assumed structure.(cont.) Simulations and experiments show that this new approach can be used to design a force-feedback controller for a robot actuator that improves performance, reduces conservatism, and maintains coupled stability. Adding dynamics in series to change an actuator's physical behavior can also improve performance. The design tools developed for controller design are adapted to select parameters for physical series dynamics and the control system simultaneously. This design procedure is applied to both spring-damper and inertial series dynamics. Results show that both structures can be advantageous, and that the systematic design of hardware and control together can improve performance dramatically over prior work. A remote transmission design is proposed to reduce actuator weight directly. This design uses a stationary direct-drive electromagnetic actuator and a passive, flexible hydraulic transmission with low intrinsic impedance, thereby utilizing the impedance- rendering capabilities of direct-drive actuation and the force density of hydraulic actuation. The design, construction and characterization of a low-weight, low-friction prototype for a human arm therapy robot are discussed. Recommendations and tradeoffs are presented.by Stephen Paul Buerger.Ph.D
    corecore