6,066 research outputs found

    Review on carbon-derived, solid-state, micro and nano sensors for electrochemical sensing applications

    Get PDF
    The aim of this review is to summarize the most relevant contributions in the development of electrochemical sensors based on carbon materials in the recent years. There have been increasing numbers of reports on the first application of carbon derived materials for the preparation of an electrochemical sensor. These include carbon nanotubes, diamond like carbon films and diamond film-based sensors demonstrating that the particular structure of these carbon material and their unique properties make them a very attractive material for the design of electrochemical biosensors and gas sensors. Carbon nanotubes (CNT) have become one of the most extensively studied nanostructures because of their unique properties. CNT can enhance the electrochemical reactivity of important biomolecules and can promote the electron-transfer reactions of proteins (including those where the redox center is embedded deep within the glycoprotein shell). In addition to enhanced electrochemical reactivity, CNT-modified electrodes have been shown useful to be coated with biomolecules (e.g., nucleic acids) and to alleviate surface fouling effects (such as those involved in the NADH oxidation process). The remarkable sensitivity of CNT conductivity with the surface adsorbates permits the use of CNT as highly sensitive nanoscale sensors. These properties make CNT extremely attractive for a wide range of electrochemical sensors ranging from amperometric enzyme electrodes to DNA hybridization biosensors. Recently, a CNT sensor based fast diagnosis method using non-treated blood assay has been developed for specific detection of hepatitis B virus (HBV) (human liver diseases, such as chronic hepatitis, cirrhosis, and hepatocellular carcinoma caused by hepatitis B virus). The linear detection limits for HBV plasma is in the range 0.5–3.0 μL−1 and for anti- HBVs 0.035–0.242 mg/mL in a 0.1 M NH4H2PO4 electrolyte solution. These detection limits enables early detection of HBV infection in suspected serum samples. Therefore, non-treated blood serum can be directly applied for real-time sensitive detection in medical diagnosis as well as in direct in vivo monitoring. Synthetic diamond has been recognized as an extremely attractive material for both (bio-) chemical sensing and as an interface to biological systems. Synthetic diamond have outstanding electrochemical properties, superior chemical inertness and biocompatibility. Recent advances in the synthesis of highly conducting nanocrystalline-diamond thin films and nano wires have lead to an entirely new class of electrochemical biosensors and bio-inorganic interfaces. In addition, it also combines with development of new chemical approaches to covalently attach biomolecules on the diamond surface also contributed to the advancement of diamond-based biosensors. The feasibility of a capacitive field-effect EDIS (electrolyte-diamond-insulatorsemiconductor) platform for multi-parameter sensing is demonstrated with an O-terminated nanocrystalline-diamond (NCD) film as transducer material for the detection of pH and penicillin concentration. This has also been extended for the label-free electrical monitoring of adsorption and binding of charged macromolecules. One more recent study demonstrated a novel bio-sensing platform, which is introduced by combination of a) geometrically controlled DNA bonding using vertically aligned diamond nano-wires and b) the superior electrochemical sensing properties of diamond as transducer material. Diamond nanowires can be a new approach towards next generation electrochemical gene sensor platforms. This review highlights the advantages of these carbon materials to promote different electron transfer reactions specially those related to biomolecules. Different strategies have been applied for constructing carbon material-based electrochemical sensors, their analytical performance and future prospects are discussed

    Index to NASA Tech Briefs, 1975

    Get PDF
    This index contains abstracts and four indexes--subject, personal author, originating Center, and Tech Brief number--for 1975 Tech Briefs

    Precise measurement of gas volumes by means of low-offset MEMS flow sensors with µL/min resolution

    Get PDF
    Experiments devoted to evaluate the performance of a MEMS thermal flow sensor in measuring gas volumes are described. The sensor is a single-chip platform, including several sensing structures and a low-offset, low-noise readout interface. A recently proposed offset compensation approach is implemented obtaining low temperature drift and excellent long time stability. The sensor is fabricated by applying a simple micromachining procedure to a chip produced using the BCD6s process of STMicroelectronics. Application of a gas conveyor allowed inclusion of the sensing structure into a channel of sub-millimeter cross-section. The results of measurements performed by making controlled air volumes pass through the sensor channel in both directions at rates from 0.1 to 5 mL/min are described

    Conception pour la testabilité des systèmes biomédicaux implantables

    Get PDF
    Architecture générale des systèmes implantables -- Principes de stimulation électrique -- Champs d'application des systèmes implantables -- Les particularités des circuits implantables -- Tendance future -- Conception pour la testabilité de la partie numérique des circuits implantables -- "Desigh and realization of an accurate built-in current sensor for Iddq testing and power dissipation measurement -- Conception pour la testabilité de la partie analogique des circuits implantables -- BIST for digital-to-analog and Analogo-to-digital converters -- Efficient and accurate testing of analog-to-digital converters using oscillation test method -- Design for testability of Embedded integrated operational amplifiers -- Vérification des interfaces bioélectroniques des systèmes implantables -- Monitorin the electrode and lead failures in implanted microstimulators and sensors -- Capteurs de température intégrés pour la vérification de l'état thermique des puces dédiées -- Built-in temperature sensors for on-line thermal monitoring of microelectronic structures -- Un protocole de communication fiable pour la programmation et la télémétrie des système implantables -- A reliable communication protoco for externally controlled biomedical implanted devices

    A Compact, Dual Channel Flow-based Differential Pressure Sensor with mPa Resolution and Sub-10 mW Power Consumption

    Get PDF
    In this work, we propose a single-chip sensor for the detection of two extremely low, independent differential pressures. The operating principle consists in measuring the airflow induced by the pressure through a channel of sub-millimeter cross-section [1]. The airflow is measured by differential thermal flow sensors, implementing a recently proposed drift-free offset compensation approach. Use of a low-noise, low-power readout interface, integrated on the same chip as the sensing structures, allowed the achievement of resolutions of 1.29 mPa, which are one order of magnitude lower than state-of-art devices. This performance has been obtained with power consumptions suitable for battery-powered applications

    An Inventive Framework of Micro-Electromechanical System (MEMS)

    Get PDF
    MEMS is an enabling technology allowing the development of smart products, enhancing the computational ability of microelectronics with the perception and control capabilities of micro sensors and micro actuators and expanding the space of possible designs and applications. MEMS is a relatively new technology which exploits the existing microelectronics infrastructure to create complex machines with micron feature sizes. MEMS promises to revolutionize nearly every product category by bringing together silicon based microelectronics with micro machining technology, making possible the realization of compl ete systems on a chip. Microelectromechanical systems (MEMS) technolog enable us to create various useful sensing and actuating devices integrated with other microelectronic, optoelectronic, microwave, thermal and mechanical devices for advanced Microsystem s. Micromachining and micro electro mechanical systems (MEMS) technologies can be used to produce complex structure, devices, and systems on the scale of micrometers. MEMS products based on piezoelectric and capacitance sensing now include pressure and flo w sensors, accelerometers, gyroscopes, microphones, digital light projectors, oscillators, and RF switches. MEMS devices are used in virtually all areas of industrial activity, health care, consumer products, construction, and milita ry and space hardware. The future of MEMS is multifaceted, complex, and subject to change, in response to the prevailing winds of investment by government and commercial entities. This diversification of product offerings and globalization of the industry has been accompanied by strong revenue growth and growing private investment. Much of the growth in MEMS business is expected to come from products that are in early stages of development or yet to be invented

    Feasibility Studies on Si-Based Biosensors

    Get PDF
    The aim of this paper is to summarize the efforts carried out so far in the fabrication of Si-based biosensors by a team of researchers in Catania, Italy. This work was born as a collaboration between the Catania section of the Microelectronic and Microsystem Institute (IMM) of the CNR, the Surfaces and Interfaces laboratory (SUPERLAB) of the Consorzio Catania Ricerche and two departments at the University of Catania: the Biomedical Science and the Biological Chemistry and Molecular Biology Departments. The first goal of our study was the definition and optimization of an immobilization protocol capable of bonding the biological sensing element on a Si-based surface via covalent chemical bonds. We chose SiO2 as the anchoring surface due to its biocompatibility and extensive presence in microelectronic devices. The immobilization protocol was tested and optimized, introducing a new step, oxide activation, using techniques compatible with microelectronic processing. The importance of the added step is described by the experimental results. We also tested different biological molecule concentrations in the immobilization solutions and the effects on the immobilized layer. Finally a MOS-like structure was designed and fabricated to test an electrical transduction mechanism. The results obtained so far and the possible evolution of the research field are described in this review paper

    RTM production monitoring of the A380 hinge arm droop nose mechanism: a multi-sensor approach

    Get PDF
    his research presents a case study of production monitoring on an aerospace composite component: the hinge arm of the droop nose mechanism on the Airbus A380 wing leading edge. A sensor network composed of Fibre Bragg Gratings, capacitive sensors for cure monitoring and thermocouples was embedded in its fibre reinforced lay-up and measurements were acquired throughout its Resin Transfer Moulding production process. Two main challenges had to be overcome: first, the integration of the sensor lines in the existing Resin Transfer Moulding mould without modifying it; second, the demoulding of the component without damaging the sensor lines. The proposed embedding solution has proved successful. The wavelength shifts of the Fibre Bragg Gratings were observed from the initial production stages, over the resin injection, the complete curing of the resin and the cooling-down prior to demoulding. The sensors proved to be sensitive to detecting the resin flow front, vacuum and pressure increase into the mould and the temperature increase caused by the resin curing. Measurements were also acquired during the post-curing cycle. Residual strains during all steps of the process were derived from the sensors’ wavelength shift, showing values up to 0.2% in compression. Moreover, the capacitive sensors were able to follow-up the curing degree during the production process. The sensors proved able to detect the resin flow front, whereas thermocouples could not measure an appreciable increase of temperature due to the fact that the resin had the same temperature as the mould
    • …
    corecore