473 research outputs found

    Ambulatory Assessment of Ankle and Foot Dynamics

    Get PDF
    Ground reaction force (GRF) measurement is important in the analysis of human body movements. The main drawback of the existing measurement systems is the restriction to a laboratory environment. This paper proposes an ambulatory system for assessing the dynamics of ankle and foot, which integrates the measurement of the GRF with the measurement of human body movement. The GRF and the center of pressure (CoP) are measured using two six-degrees-of-freedom force sensors mounted beneath the shoe. The movement of foot and lower leg is measured using three miniature inertial sensors, two rigidly attached to the shoe and one on the lower leg. The proposed system is validated using a force plate and an optical position measurement system as a reference. The results show good correspondence between both measurement systems, except for the ankle power estimation. The root mean square (RMS) difference of the magnitude of the GRF over 10 evaluated trials was (0.012 plusmn 0.001) N/N (mean plusmn standard deviation), being (1.1 plusmn 0.1)% of the maximal GRF magnitude. It should be noted that the forces, moments, and powers are normalized with respect to body weight. The CoP estimation using both methods shows good correspondence, as indicated by the RMS difference of (5.1 plusmn 0.7) mm, corresponding to (1.7 plusmn 0.3)% of the length of the shoe. The RMS difference between the magnitudes of the heel position estimates was calculated as (18 plusmn 6) mm, being (1.4 plusmn 0.5)% of the maximal magnitude. The ankle moment RMS difference was (0.004 plusmn 0.001) Nm/N, being (2.3 plusmn 0.5)% of the maximal magnitude. Finally, the RMS difference of the estimated power at the ankle was (0.02 plusmn 0.005) W/N, being (14 plusmn 5)% of the maximal power. This power difference is caused by an inaccurate estimation of the angular velocities using the optical reference measurement system, which is due to considering the foot as a single segment. The ambulatory system considers separat- - e heel and forefoot segments, thus allowing an additional foot moment and power to be estimated. Based on the results of this research, it is concluded that the combination of the instrumented shoe and inertial sensing is a promising tool for the assessment of the dynamics of foot and ankle in an ambulatory setting

    Indirect Estimation of Vertical Ground Reaction Force from a Body-Mounted INS/GPS Using Machine Learning

    Get PDF
    Vertical ground reaction force(vGRF)can be measured by forceplates or instrumented treadmills, but their application is limited to indoor environments. Insoles remove this restriction but suffer from low durability (several hundred hours). Therefore, interest in the indirect estimation of vGRF using inertial measurement units and machine learning techniques has increased. This paper presents a methodology for indirectly estimating vGRF and other features used in gait analysis from measurements of a wearable GPS-aided inertial navigation system (INS/GPS) device. A set of 27 features was extracted from the INS/GPS data. Feature analysis showed that six of these features suffice to provide precise estimates of 11 different gait parameters. Bagged ensembles of regression trees were then trained and used for predicting gait parameters for a dataset from the test subject from whom the training data were collected and for a dataset from a subject for whom no training data were available. The prediction accuracies for the latter were significantly worse than for the first subject but still sufficiently good. K-nearest neighbor (KNN) and long short-term memory (LSTM) neural networks were then used for predicting vGRF and ground contact times. The KNN yielded a lower normalized root mean square error than the neural network for vGRF predictions but cannot detect new patterns in force curves.publishedVersionPeer reviewe

    Hip Joint Angles and Moments during Stair Ascent Using Neural Networks and Wearable Sensors

    Get PDF
    End-stage hip joint osteoarthritis treatment, known as total hip arthroplasty (THA), improves satisfaction, life quality, and activities of daily living (ADL) function. Postoperatively, evaluating how patients move (i.e., their kinematics/kinetics) during ADL often requires visits to clinics or specialized biomechanics laboratories. Prior work in our lab and others have leveraged wearables and machine learning approaches such as artificial neural networks (ANNs) to quantify hip angles/moments during simple ADL such as walking. Although level-ground ambulation is necessary for patient satisfaction and post-THA function, other tasks such as stair ascent may be more critical for improvement. This study utilized wearable sensors/ANNs to quantify sagittal/frontal plane angles and moments of the hip joint during stair ascent from 17 healthy subjects. Shin/thigh-mounted inertial measurement units and force insole data were inputted to an ANN (2 hidden layers, 10 total nodes). These results were compared to gold-standard optical motion capture and force-measuring insoles. The wearable-ANN approach performed well, achieving rRMSE = 17.7% and R2 = 0.77 (sagittal angle/moment: rRMSE = 17.7 ± 1.2%/14.1 ± 0.80%, R2 = 0.80 ± 0.02/0.77 ± 0.02; frontal angle/moment: rRMSE = 26.4 ± 1.4%/12.7 ± 1.1%, R2 = 0.59 ± 0.02/0.93 ± 0.01). While we only evaluated healthy subjects herein, this approach is simple and human-centered and could provide portable technology for quantifying patient hip biomechanics in future investigations

    Augmenting forearm crutches with wireless sensors for lower limb rehabilitation

    No full text
    Forearm crutches are frequently used in the rehabilitation of an injury to the lower limb. The recovery rate is improved if the patient correctly applies a certain fraction of their body weight (specified by a clinician) through the axis of the crutch, referred to as partial weight bearing (PWB). Incorrect weight bearing has been shown to result in an extended recovery period or even cause further damage to the limb. There is currently no minimally invasive tool for long-term monitoring of a patient's PWB in a home environment. This paper describes the research and development of an instrumented forearm crutch that has been developed to wirelessly and autonomously monitor a patient's weight bearing over the full period of their recovery, including its potential use in a home environment. A pair of standard forearm crutches are augmented with low-cost off-the-shelf wireless sensor nodes and electronic components to provide indicative measurements of the applied weight, crutch tilt and hand position on the grip. Data are wirelessly transmitted between crutches and to a remote computer (where they are processed and visualized in LabVIEW), and the patient receives biofeedback by means of an audible signal when they put too much or too little weight through the crutch. The initial results obtained highlight the capability of the instrumented crutch to support physiotherapists and patients in monitoring usage

    A three-pressure-sensor (3PS) system for monitoring ankle supination torque during sport motions

    Get PDF
    This study presented a three-pressure-sensor (3PS) system for monitoring ankle supination torque during sport motions. Five male subjects wore a pair of cloth sport shoes and performed 10 trials of walking, running, cutting, vertical jump-landing and stepping-down motions in a random sequence. A pair of pressure insoles (Novel Pedar model W, Germany) was inserted in the shoes for the measurement of plantar pressure at 100 Hz. The ankle joint torque was calculated by a standard lower extremity inverse dynamic calculation procedure with the data obtained by a motion capture system (VICON, UK) and a force plate (AMTI, USA), and was presented in a supination/pronation plane with an oblique axis of rotation at the ankle joint. Stepwise linear regression analysis suggested that pressure data at three locations beneath the foot were essential for reconstructing the ankle supination torque. Another group of five male subjects participated in a validation test with the same procedure, but with the pressure insoles replaced by the 3PS system. Estimated ankle supination torque was calculated from the equation developed by the regression analysis. Results suggested that the correlation between the standard and estimated data was high (R=0.938). The overall root mean square error was 6.91 N m, which was about 6% of the peak values recorded in the five sport motions (113 N m). With the good estimation accuracy, tiny size and inexpensive cost, the 3PS system is readily available to be implanted in sport shoe for the estimation and monitoring of ankle supination torque during dynamic sport motions

    Developing a method for quantifying hip joint angles and moments during walking using neural networks and wearables

    Get PDF
    Quantifying hip angles/moments during gait is critical for improving hip pathology diagnostic and treatment methods. Recent work has validated approaches combining wearables with artificial neural networks (ANNs) for cheaper, portable hip joint angle/moment computation. This study developed a Wearable-ANN approach for calculating hip joint angles/moments during walking in the sagittal/frontal planes with data from 17 healthy subjects, leveraging one shin-mounted inertial measurement unit (IMU) and a force-measuring insole for data capture. Compared to the benchmark approach, a two hidden layer ANN (n = 5 nodes per layer) achieved an average rRMSE = 15% and R2=0.85 across outputs, subjects and training rounds

    Doctor of Philosophy

    Get PDF
    dissertationThis thesis analyzed biped stability through a qualitative likelihood of falling and quantitative Potential to Fall (PF) analysis. Both analyses were applied to walking and skiing to better understand behaviors across a wider spectrum of bipedal gaits. For both walking and skiing, two types of locomotion were analyzed. Walking studies compared normal locomotion (gait) to an unexpected slip. Skiing studies compared wedge style locomotion (more common to beginning and intermediate skiers) to parallel style locomotion (more common to advanced and expert skiers). Two mediums of data collection were used. A motion capture laboratory with stereographic cameras and force plates were used for walking studies, and instrumented insoles, capable of force and inertial measurement, were used for skiing studies. Both kinematics and kinetics were used to evaluate the likelihood of falling. The PF metric, based on root mean squared error, was used to quantify the likelihood of falling for multiple subjects both in walking and skiing. PF was based on foot kinematics for walking and skiing studies. PF also included center of pressure for skiing studies. The PF was lower for normal gaits in walking studies and wedge style locomotion for skiing studies

    Acute Effects of Muscular Fatigue on Vertical Jump Performance in Acrobatic Gymnasts, Evaluated by Instrumented Insoles: A Pilot Study

    Get PDF
    The study of fatigue during training is becoming a very useful tool to avoid possible injuries not only during the training sessions but also during recovery time. Many researches have proved that concepts such as muscular fatigue and postactivation potentiation have a close relationship. With this aim, vertical jump can provide a very important information that can help to analyze the muscular fatigue that happened during this type of activity, mainly if the monitoring system is able to measure jumping parameters during their regular training session in their natural training environment. This study was performed with instrumented insoles called ECnsole. These insoles were tested with a group of twelve volunteers. In a tumbling surface, the participants performed a jumping protocol in three conditions: rest, fatigue-induced, and recovery. Using these validated insoles, the acrobatic gymnasts showed an inability to use the stretch-shortening cycle for improving vertical jumping performance after fatigue condition, although no deterioration of jump performance was found.Junta de Andalucía European Commission P10-TIC5997European Commissio

    Validity of the Loadsol Pro Insole for Pedal Reaction Force Measurements During Stationary Cycling

    Get PDF
    Advancements in wearable technology have allowed clinicians, coaches, and researchers the ability to observe and quantify human movement outside the laboratory. Instrumented insoles are an example of novel technology that can be worn in the shoes and measure vertical reaction force wirelessly. The use of such insoles will prove to be beneficial for athletes as they train, patients as they progress through rehabilitation, and researchers as they experiment in their respective fields. The Loadsol Pro (Novel Inc., St Paul., MN, USA) has been shown to produce accurate and reliable measures of ground reaction forces (GRF) in various dynamic activities including walking, running, and landing. However, the insoles have yet to be validated during bouts of stationary cycling. The standard for measuring forces during cycling is through instrumented bike pedals, yet such technology is costly, difficult to obtain, and requires extensive training. The purpose of the current study was to analyze the validity of the Loadsol Pro insole for pedal reaction force (PRF) measurements during stationary cycling. A total of 18 healthy subjects (age: 20.94 ± 2.24 years, weight: 72.4 ± 23.32 kg, height: 1.67 ± 0.06 m, body mass index: 25.72 ± 7.57 kg/m2) participated in the study. The Loadsol Pro insoles (200 Hz) and custom instrumented bike pedals (1200 Hz) were used to collect PRF data during bouts of stationary cycling at 50 W, 75 W, and 100 W. A paired samples t-test was performed to observe the agreement between both measurement systems and Cohen’s d effect size was calculated to indicate the effect of the observed differences. The paired samples t-test resulted in no statistically significant differences in peak PRF measured by the Loadsol and the instrumented pedals. Cohen’s d effect size resulted in small effect sizes between the Loadsol PRF and pedal PRF. Across all conditions, mean differences between the Loadsol PRF and pedal PRF were calculated to be less than 6 N with marginal errors under 4%. Thus, the Loadsol can be used to accurately measure peak PRF forces across work rates during stationary cycling. The introduction of the Loadsol to stationary cycling will provide easier access to data that is influential for health and in rehabilitative advances, and representative of athletic performance

    Validation of plantar pressure and reaction force measured by Moticon pressure sensor insoles on a Concept2 rowing ergometer

    Get PDF
    The purpose of this study was to determine the reliability and validity of plantar pressure and reaction force measured using the Moticon and Pedar-x sensor insoles while rowing on a Concept2 ergometer. Nineteen participants performed four 500 m trials of ergometer rowing at 22–24 strokes/min; two trials wearing Moticon insoles and two wearing Pedar-x insoles in a randomised order. Moticon and Pedar-x insoles both showed moderate to strong test–retest reliability (ICC = 0.57–0.92) for mean and peak plantar pressure and reaction force. Paired t-test demonstrated a significant difference (p 1.13), and Pearson’s correlation (r < 0.37) showed poor agreement for all plantar pressure and reaction force variables. Compared to Pedar-x, the Moticon insoles demonstrated poor validity, however, the Moticon insoles had strong reliability. Due to poor validity, caution should be used when considering Moticon insoles to assess changes in pressure and force reliably over time, across multiple trials or sessions. Moticon’s wireless and user-friendly application would be beneficial for assessing and monitoring biomechanical parameters in rowing if validity between measures of interest and Moticon’s results can be established