610 research outputs found

    Unsupervised Heart-rate Estimation in Wearables With Liquid States and A Probabilistic Readout

    Full text link
    Heart-rate estimation is a fundamental feature of modern wearable devices. In this paper we propose a machine intelligent approach for heart-rate estimation from electrocardiogram (ECG) data collected using wearable devices. The novelty of our approach lies in (1) encoding spatio-temporal properties of ECG signals directly into spike train and using this to excite recurrently connected spiking neurons in a Liquid State Machine computation model; (2) a novel learning algorithm; and (3) an intelligently designed unsupervised readout based on Fuzzy c-Means clustering of spike responses from a subset of neurons (Liquid states), selected using particle swarm optimization. Our approach differs from existing works by learning directly from ECG signals (allowing personalization), without requiring costly data annotations. Additionally, our approach can be easily implemented on state-of-the-art spiking-based neuromorphic systems, offering high accuracy, yet significantly low energy footprint, leading to an extended battery life of wearable devices. We validated our approach with CARLsim, a GPU accelerated spiking neural network simulator modeling Izhikevich spiking neurons with Spike Timing Dependent Plasticity (STDP) and homeostatic scaling. A range of subjects are considered from in-house clinical trials and public ECG databases. Results show high accuracy and low energy footprint in heart-rate estimation across subjects with and without cardiac irregularities, signifying the strong potential of this approach to be integrated in future wearable devices.Comment: 51 pages, 12 figures, 6 tables, 95 references. Under submission at Elsevier Neural Network

    Modelling mobile health systems: an application of augmented MDA for the extended healthcare enterprise

    Get PDF
    Mobile health systems can extend the enterprise computing system of the healthcare provider by bringing services to the patient any time and anywhere. We propose a model-driven design and development methodology for the development of the m-health components in such extended enterprise computing systems. The methodology applies a model-driven design and development approach augmented with formal validation and verification to address quality and correctness and to support model transformation. Recent work on modelling applications from the healthcare domain is reported. One objective of this work is to explore and elaborate the proposed methodology. At the University of Twente we are developing m-health systems based on Body Area Networks (BANs). One specialization of the generic BAN is the health BAN, which incorporates a set of devices and associated software components to provide some set of health-related services. A patient will have a personalized instance of the health BAN customized to their current set of needs. A health professional interacts with their\ud patientsÂż BANs via a BAN Professional System. The set of deployed BANs are supported by a server. We refer to this distributed system as the BAN System. The BAN system extends the enterprise computing system of the healthcare provider. Development of such systems requires a sound software engineering approach and this is what we explore with the new methodology. The methodology is illustrated with reference to recent modelling activities targeted at real implementations. In the context of the Awareness project BAN implementations will be trialled in a number of clinical settings including epilepsy management and management of chronic pain

    Federated Learning on Edge Sensing Devices: A Review

    Full text link
    The ability to monitor ambient characteristics, interact with them, and derive information about the surroundings has been made possible by the rapid proliferation of edge sensing devices like IoT, mobile, and wearable devices and their measuring capabilities with integrated sensors. Even though these devices are small and have less capacity for data storage and processing, they produce vast amounts of data. Some example application areas where sensor data is collected and processed include healthcare, environmental (including air quality and pollution levels), automotive, industrial, aerospace, and agricultural applications. These enormous volumes of sensing data collected from the edge devices are analyzed using a variety of Machine Learning (ML) and Deep Learning (DL) approaches. However, analyzing them on the cloud or a server presents challenges related to privacy, hardware, and connectivity limitations. Federated Learning (FL) is emerging as a solution to these problems while preserving privacy by jointly training a model without sharing raw data. In this paper, we review the FL strategies from the perspective of edge sensing devices to get over the limitations of conventional machine learning techniques. We focus on the key FL principles, software frameworks, and testbeds. We also explore the current sensor technologies, properties of the sensing devices and sensing applications where FL is utilized. We conclude with a discussion on open issues and future research directions on FL for further studie

    An application of augmented MDA for the extended healthcare enterprise

    Get PDF
    Mobile health systems extend the enterprise computing system of the healthcare provider by bringing services to the patient any time and anywhere. We propose a methodology for the development of such extended enterprise computing systems which applies a model-driven design and development approach augmented with formal validation and verification to address quality and correctness and to support model transformation. At the University of Twente we develop context aware m-health systems based on Body Area Networks (BANs). A set of deployed BANs are supported by a server. We refer to this distributed system as a BAN System. Development of such distributed m-health systems requires a sound software engineering approach and this is what we target with the proposed methodology. The methodology is illustrated with reference to modelling activities targeted at real implementations. BAN implementations are being trialled in a number of clinical settings including epilepsy management and management of chronic pain

    Personal heart monitoring and rehabilitation system using smart phones

    Full text link
    This paper discusses a personalized heart monitoring system using smart phones and wireless (bio) sensors. Based on several scenarios we present the functionality of a prototype we have built. The application is capable of monitoring the health of high risk cardiac patients. The smart phone application analyses in real-time sensor and environmental data and can automatically alert the ambulance and pre assigned caregivers when a heart patient is in danger. It also transmits sensor data to a healthcare centre for remote monitoring by a nurse or cardiologist. The system can be personalized and rehabilitation programs can monitor the progress of a patient. Rehabilitation programs can be used to give advice (e.g. exercise more) or to reassure the patient. © 2006 IEEE

    Smart vest for respiratory rate monitoring of COPD patients based on non-contact capacitive sensing

    Get PDF
    In this paper, a first approach to the design of a portable device for non-contact monitoring of respiratory rate by capacitive sensing is presented. The sensing system is integrated into a smart vest for an untethered, low-cost and comfortable breathing monitoring of Chronic Obstructive Pulmonary Disease (COPD) patients during the rest period between respiratory rehabilitation exercises at home. To provide an extensible solution to the remote monitoring using this sensor and other devices, the design and preliminary development of an e-Health platform based on the Internet of Medical Things (IoMT) paradigm is also presented. In order to validate the proposed solution, two quasi-experimental studies have been developed, comparing the estimations with respect to the golden standard. In a first study with healthy subjects, the mean value of the respiratory rate error, the standard deviation of the error and the correlation coefficient were 0.01 breaths per minute (bpm), 0.97 bpm and 0.995 (p < 0.00001), respectively. In a second study with COPD patients, the values were -0.14 bpm, 0.28 bpm and 0.9988 (p < 0.0000001), respectively. The results for the rest period show the technical and functional feasibility of the prototype and serve as a preliminary validation of the device for respiratory rate monitoring of patients with COPD.Ministerio de Ciencia e InnovaciĂłn PI15/00306Ministerio de Ciencia e InnovaciĂłn DTS15/00195Junta de AndalucĂ­a PI-0010-2013Junta de AndalucĂ­a PI-0041-2014Junta de AndalucĂ­a PIN-0394-201

    Guest Editorial Special Issue on Medical Imaging and Image Computing in Computational Physiology

    Get PDF
    International audienceThe January 2013 Special Issue of IEEE transactions on medical imaging discusses papers on medical imaging and image computing in computational physiology. Aslanid and co-researchers present an experimental technique based on stained micro computed tomography (CT) images to construct very detailed atrial models of the canine heart. The paper by Sebastian proposes a model of the cardiac conduction system (CCS) based on structural information derived from stained calf tissue. Ho, Mithraratne and Hunter present a numerical simulation of detailed cerebral venous flow. The third category of papers deals with computational methods for simulating medical imagery and incorporate knowledge of imaging physics and physiology/biophysics. The work by Morales showed how the combination of device modeling and virtual deployment, in addition to patient-specific image-based anatomical modeling, can help to carry out patient-specific treatment plans and assess alternative therapeutic strategies
    • …
    corecore