5,036 research outputs found

    Influence of the Feedback Filter on the Response of the Pulsed Digital Oscillator

    Get PDF
    This paper introduces a new feedback topology for the Pulsed Digital Oscillator (PDO) and compares it to the classical topology. The `classic' or single feedback topology, introduced in previous works, shows a strong behavior dependence on the damping losses in the MEMS resonator. A new double feedback topology is introduced here in order to help solving this problem. Comparative discrete-time simulations and preliminary experimental measurements have been carried out for both topologies, showing how the new double feedback topology may increase PDO performance for some frequency ranges.Comment: Submitted on behalf of TIMA Editions (http://irevues.inist.fr/tima-editions

    Linear analysis of the influence of FIR feedback filters on the response of the pulsed digital oscillator

    Get PDF
    The original publication is available at www.springerlink.comThe objective of this work is to extend the linear analysis of PulsedDigitalOscillators to those topologies having a Finite Impulse Response (FIR) in the feedback loop of the circuit. It will be shown with two specific examples how the overall response of the oscillator can be adjusted to some point by changing the feedback filter, when the resonator presents heavy damping losses. Extensive discrete-time simulations and experimental results obtained with a MEMS cantilever with thermoelectric actuation and piezoresistive position sensing are presented. It will be experimentally shown that the performance of the oscillator is good even below the Nyquist limit

    Generation of picosecond pulsed coherent state superpositions

    Get PDF
    We present the generation of approximated coherent state superpositions - referred to as Schr\"odinger cat states - by the process of subtracting single photons from picosecond pulsed squeezed states of light at 830 nm. The squeezed vacuum states are produced by spontaneous parametric down-conversion (SPDC) in a periodically poled KTiOPO4 crystal while the single photons are probabilistically subtracted using a beamsplitter and a single photon detector. The resulting states are fully characterized with time-resolved homodyne quantum state tomography. Varying the pump power of the SPDC, we generated different states which exhibit non-Gaussian behavior.Comment: 17 pages, 8 figures, 3 table

    RESOLUTION LIMITS FOR RESONANT MEMS SENSORS BASED ON DISCRETE RELAY FEEDBACK TECHNIQUES

    Get PDF
    Submitted on behalf of EDA Publishing Association (http://irevues.inist.fr/handle/2042/5920)International audienceThis paper is devoted to the analysis of resonant MEMS sensors based on discrete relay feedback techniques. One drawback of such techniques is that some synchronization usually occurs between the discrete part and the continuous part of the system: this results in sensor responses that are very similar to the curves known as devil's staircases, i.e. the frequency does not vary smoothly with the sensor's input. The main contribution of this paper is a theoretical calculation of the resolution of such systems. The resolutions of two existing resonant MEMS architectures are then calculated and these results are discussed

    Noise Measurement Setup for Quartz Crystal Microbalance

    Get PDF
    Quartz crystal microbalance (QCM) is a high sensitive chemical sensor which has found widespread spectrum of applications. There are several mechanisms that are related to fluctuation phenomena. Since the aim of our research is oriented to study the sensitivity and influence of different kind of noises on sensor resolution, we modified an existing method to measure the small frequency fluctuation of QCM. The paper describes our measurement setup, in which a quartz crystal oscillator with coated active layers and a reference quartz oscillator are driven by two oscillator circuits. Each one regulates a frequency of a crystal at the minimum impedance which corresponds to the series resonance. A data-acquisition card triggers on the rise-edges of the output signal and stores these corresponding times on which the instantaneous frequency is estimated by own-written software. In comparison to other measurement setups, our approach can acquire immediate change of QCM frequency, thus, chemical processes can be even described on the basis of high-order statistics. The experiments were provided on quartz crystals with the sorption layer of polypyrrole, which is suitable for the construction of QCM humidity sensors

    Study of Single-Event Transient Effects on Analog Circuits

    Get PDF
    Radiation in space is potentially hazardous to microelectronic circuits and systems such as spacecraft electronics. Transient effects on circuits and systems from high energetic particles can interrupt electronics operation or crash the systems. This phenomenon is particularly serious in complementary metal-oxide-semiconductor (CMOS) integrated circuits (ICs) since most of modern ICs are implemented with CMOS technologies. The problem is getting worse with the technology scaling down. Radiation-hardening-by-design (RHBD) is a popular method to build CMOS devices and systems meeting performance criteria in radiation environment. Single-event transient (SET) effects in digital circuits have been studied extensively in the radiation effect community. In recent years analog RHBD has been received increasing attention since analog circuits start showing the vulnerability to the SETs due to the dramatic process scaling. Analog RHBD is still in the research stage. This study is to further study the effects of SET on analog CMOS circuits and introduces cost-effective RHBD approaches to mitigate these effects. The analog circuits concerned in this study include operational amplifiers (op amps), comparators, voltage-controlled oscillators (VCOs), and phase-locked loops (PLLs). Op amp is used to study SET effects on signal amplitude while the comparator, the VCO, and the PLL are used to study SET effects on signal state during transition time. In this work, approaches based on multi-level from transistor, circuit, to system are presented to mitigate the SET effects on the aforementioned circuits. Specifically, RHBD approach based on the circuit level, such as the op amp, adapts the auto-zeroing cancellation technique. The RHBD comparator implemented with dual-well and triple-well is studied and compared at the transistor level. SET effects are mitigated in a LC-tank oscillator by inserting a decoupling resistor. The RHBD PLL is implemented on the system level using triple modular redundancy (TMR) approach. It demonstrates that RHBD at multi-level can be cost-effective to mitigate the SEEs in analog circuits. In addition, SETs detection approaches are provided in this dissertation so that various mitigation approaches can be implemented more effectively. Performances and effectiveness of the proposed RHBD are validated through SPICE simulations on the schematic and pulsed-laser experiments on the fabricated circuits. The proposed and tested RHBD techniques can be applied to other relevant analog circuits in the industry to achieve radiation-tolerance

    Advances in electronics prompt a fresh look at continuous wave (CW) nuclear magnetic resonance (NMR)

    Get PDF
    Continuous Wave Nuclear Magnetic Resonance (CW-NMR) was a popular method for sample interrogation at the birth of magnetic resonance but has since been overlooked by most in favor of the now more popular pulsed techniques. CW-NMR requires relatively simple electronics although, for most designs, the execution is critical to the successful implementation and sensitivity of the system. For decades there have been reports in the literature from academic groups showing the potential of magnetic resonance relaxation time measurements in industrial applications such as the production of food and drink. However, the cost, complexity and power consumption of pulsed techniques have largely consigned these to the literature. Advances in electronics and developments in permanent magnet technology now require a fresh look at CW-NMR to see if it is capable of providing cost effective industrial solutions. In this article, we review the electronics that are needed to undertake a continuous wave NMR experiment starting with early designs and journeying through the literature to understand the basic designs and limitations. We then review the more recent developments in this area and present an outlook for future work in the hope that more of the scientific community will take a fresh look at CW-NMR as a viable and powerful low-cost measurement technique
    • …
    corecore